BEA LZR-MICROSCAN T Door Control Wiring Matrix Instructions

May 15, 2024
BEA

BEA LZR-MICROSCAN T Door Control Wiring Matrix
BEA LZR-MICROSCAN T Door Control Wiring Matrix

BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS

BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device; therefore, BEA, Inc. does not guarantee any use of the sensor/device outside of its intended purpose.

BEA, Inc. strongly recommends that installation and service technicians be AAADM certified for pedestrian doors, IDA-certified for doors/gates, and factory-trained for the type of door/gate system.

Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor/device system performance is compliant with local, national, and international regulations, codes, and standards.

Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer’s recommendations and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL294, UL325, and International Building Code).

Verify that all appropriate industry signage, warning labels, and placards are in place.

Logos

| Pwr Harness (20.5095)| Door Control Harness (20.5222)| System Harness (20.5304)
---|---|---|---
R| Bk| G| Y| W| G| Y| W| O| O| Gy| P
R| R| R| Gy| Bl
POWER 1| ACT (N.O.)| ACT (N.C.)| ACT (COM)| STALL (N.O.)| STALL (N.C.)| STALL (COM)| HOME
see note 2| HOME
see note 2| PUSH PLATE| MONITORING 3
Besam ETIK 4| 30.5558| 13| | 12| | 15/17| 16/18| DPS| Connect any dry-contact, knowing act device to the 2 gray wires.
Be certain to turn on Knowing Act at the hub.| Not supported.
Besam MP/CUP| 30.5558| 3| | 4| 5| | 4| DPS| Not supported.
Besam Power Swing/EXB| 30.5558| TB3-21| | TB3-20| | TB4-29| TB4-26| DPS| Not supported.
Besam SM 900/CU2| 30.5558| 1| | 3| TB1-7| | 3| DPS| Not supported.
Assa Abloy SW 100/200, Ditec HA9 5| 24V+| GND| CU-ESD 2| | CU-ESD 1| | EXU-SA 3| EXU-SA1| EXU-SA 7| EXU-SA 8| Refer to BEA product User’s Guide and OEM manual.
CONDOR| 30.5558| ACTIVATE 17| | COM 16| DMS O| | COMMON N| DPS| Not supported.
DCU DC700
Access Auto. ES500 Quad Systems ES500| 30.5558| CN2 #2| | CN2 #3| CN6 GREEN| | CN6 BLACK| DPS| Not supported.
Detex BS1000S/UDC100| 30.5558| 2| | 1| 5| | 1| DPS| Not supported.
Dor-O-Matic| 30.5558| YELLOW| | GRAY| PURPLE| | GRAY| DPS| Not supported.
Dorma 400/700| 30.5558| TRIGGER| | GND| SWING| | GND| DPS| Not supported.
Dorma ED 100/250 6| 1| 3| 42| | 3| | 15| 3| 97| 98| Refer to BEA product User’s Guide and OEM manual.
Gyrotech/Nabco Magnum| 30.5558| 6 BLACK| | 5 RED| 3 VIOLET| | 5 RED| DPS| Not supported.
Gyrotech/Nabco Opus| 30.5558| 3| | 2| 5| | 2| DPS| Refer to BEA product User’s Guide and OEM manual.
Gyrotech/Nabco U19| 30.5558| 61/62| | RED 7| WHITE 6B| | RED 7| DPS| Not supported .
Gyrotech 300/400 7| 30.5558| BLACK| | RED| WHITE| | RED| DPS| Not supported.
Horton 4160-3 8| 30.5558| BLACK| | WHITE| DAUGHTER BOARD| | DAUGHTER BOARD| DPS| Not supported.
Horton 4190| 30.5558| 2| | 3| 10| | 3| DPS| Not supported.
Horton 5190 9| 30.5558| CN20

2 = interior

3 = exterior

| | CN7 COM| CN16 ORANGE (10)| | CN16 YELLOW (9)| DPS| Not supported.
Hunter HA, Ditec HA8| 30.5558| ACT| | RTN| SAFE 2| | RTN| DPS| Not supported.
Keane-Monroe K| 30.5558| GREEN| | WHITE| YELLOW| | WHITE| DPS| Not supported.
LCN Digital / Senior Swing| 30.5558| P6 YELLOW| | P6 GRAY| P2 GREEN| | P2 WHITE| DPS| Not supported.
Record 6000/8000 10| 4| 6| 2| | 1| | 10| 11| DPS| Refer to BEA product User’s Guide and OEM manual.
Stanley “L” 11| 30.5558| ORANGE| | YELLOW| BLUE| | YELLOW| DPS| Not supported.
Stanley MP| 30.5558| 2| | 8| 7| | 8| DPS| Not supported.
Stanley MC 521 12| 30.5558| TB4-4| | TB4-3| TB3-4| | TB3-3| see note 3| Refer to BEA product User’s Guide and OEM manual.
Stanley MC 521 Pro and IQ 12| TB4-5| TB4-6| TB4-4| | TB4-3| TB3-4| | TB3-3| see note 3| Refer to BEA product User’s Guide and OEM manual.
Tucker| 30.5558| J4-10| | J4-8 jumped to 12 & 13| | J4-14| J4-8 jumped to 12 & 13| J5 – 4 and 5| Not supported.
Tormax 130iMotion| 30.5558| INPUT C #2| | INPUT C #1| SAFETY A #2| | SAFETY A #1| DPS| Refer to BEA product User’s Guide and OEM manual.
Tormax TDA| 30.5558| 2| | 8| 7| | 8| DPS| Not supported.
Tormax TTX II| 30.5558| 5| | 4| | | 14| DPS| Not supported.
Note 1| If only VAC power is available, a 12V transformer paired with a rectifier must be used. Do not use a 24V transformer and rectifier as this will cause damage to the product.
---|---
Note 2| Auxiliary Switch: If installing onto a pair or double-egress, ensure to series both home switches. Switches must close when door is closed.
Note 3| Monitoring consists of two purple and two blue wires. If monitoring is not used, cap off unused purple and blue wires. Wire as follows:| Door Type| System Harness| Control Monitoring
---|---|---

Single

| 1 blue + 1 purple| 1st leg
1 blue + 1 purple| 2nd leg

Pair / Dual Egress

| 1 blue + 1 purple| 1st leg
1 blue + 1 purple| 2nd leg
Pair / Dual Egress

(independent controls)

| 2 blues| 1st control
2 purples| 2nd control

Effective November 11, 2017: Monitoring is required for ANSI 156.10 compliance.

Note 4
(BESAM ETIK)| Jump 17+18, if not used.
Note 5
(BESAM SW 100/200, Ditec HA9)| Set EXU-SA jumper to “Door open/closed” indication. Jump 1+2 on EXU-SA board.
Blanking Potentiometer must be set fully counterclockwise.
Auxiliary switch may be used for home switch.
Note 6
(DORMA ED 100/250)| Jump 11+3 on control.
Use ON/OFF/H.O. jumper. Control switches must be used. Make certain Home Switch Control Function “Sr” is set to 1.
Note 7
(GYROTECH 300/400)| Set control to “swing-safe.”
Note 8
(HORTON 4160-3)| Must have daughter board.
Note 9

(HORTON 5190)

| If using the MICROSCAN On/Off/Hold switch, BEA recommends using CN20 terminal 2.

The CN1 harness will sync two operators so you do not have to use both door control “a” and “b” harnesses.

Note 10
(RECORD 6000/8000)| Jump 11+12 and 14+15.
Note 11
(STANLEY “L”)| The older Stanley, all metal (silver), “L” shape control does not have stall. A control with stall must be used.
Note 12
(STANLEY MC521 / MC521 PRO and IQ)| Jump TB2 2+3 (if not using factory On/Off/Hold Switch).

Customer Support

Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462
General Tech Questions: [email protected] | www.BEAsensors.com

78.6023.02 LZR-MICROSCAN WIRING MATRIX 20240214

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BEA User Manuals

Related Manuals