Table of Contents
BEA 10UBRACKETUL Glass Door Mounting Kit For MAGLOCKS
Dimension
Mounting Instructions
- Place the steel bushing and rubber bushing according to the drawing.
- Use the 3 set screws to clamp the glass firmly. A suitable thread lock should be applied to all fixing screws.
- Insert the aluminum bar and attach armature plate. The aluminum bar can be adjusted so that it matches the MAGLOCK.
NOTE: Do not overtighten the mounting screw of the armature plate. Allow floating movement for maximum holding force.
INSTALLATION
BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
BEA Inc., the sensor manufacturer, cannot be held responsible for incorrect
installations or incorrect adjustments of the sensor/device; therefore, BEA
Inc. does not guarantee any use of the sensor/device outside its intended
purpose.
BEA Inc. strongly recommends that installation and service technicians be
AAADM-certified for pedestrian doors, IDA certified for doors/gates, and
factory-trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk
assessment following each installation/service performed, ensuring that the
sensor/ device system performance is compliant with local, national, and
international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the
system shall be performed and documented per the manufacturer’s
recommendations or industry guidelines. Examples of compliance may apply to
ANSI 156.10, ANSI 156.19, ANSI/DASMA 102, ANSI/DASMA 107, UL294, UL325, and
International Building Code.