Banggood LD-S866 Control Panel Instruction Manual

June 4, 2024
banggood

LD-S866 manual control panel
usage instructions 2018 latest
version -V1.0

First, the appearance size and material

Product shell for ABS, liquid crystal transparent window imported high hardness acrylic, hardness value is equivalent to toughened glass.

Working voltage and wiring mode

  1. working voltage: DC24V, 36V, 48V, 60V  compatible, other voltages can be customized.
  2. Wiring mode:

Note: the leads of some products use waterproof connectors, so the user cannot see the color of the leads in the wiring harness.

Function Description:

Can work:

  1. Display function
    Speed display, power indicator, fault prompt, total mileage, single mileage

  2. Control and setup functions
    Power switch control, wheel diameter setting, idle automatic sleep time setting, backlight brightness setting, starting mode setting, driving mode setting, voltage level setting, controller current limit value setting,

  3. Communication protocol: UART All contents of the display screen (all displayed within 1S after boot)

Display content introduction

  1. Display of battery now remaining BMS power

  2. Multi-function display area
    Total mileage ODO, single mileage TRIP (unit: mile, km), single start-up TIME TIME, battery voltage VOL, DST: endurance mileage

  3. Speed display area
    AVG: average SPEED, MAX: maximum SPEED, SPEED: current SPEED; Unit of Mp/h, km/h The speed signal is taken from the Hall signal in the motor and sent to the instrument by the controller (the time of a single Hall cycle, unit: 1MS). The instrument will calculate the real speed according to the wheel diameter and signal data (the Hall of the motor also needs to set the number of magnetic steel).

  4. Vehicle assistance gear adjustment 0-9 digital display and gear bar display;

  5. Vehicle status display area
    : Motor failure;| : failure;| : Brake prompt;| : Headlight on prompt;
    ---|---|---|---

4. Set the

P01: Backlight brightness, level 1 is the darkest, level 3 is the brightest;
P02: mileage unit, 0: KM;1: the MILE;
P03: voltage grade: 24V, 36V, 48V, 60V, 64V default 36V; P04: Sleep time: 0, not sleep;Other numbers are hibernation time, range: 1-60; Unit of minutes; P05: Power gear: 0, 3 mode: 1, 5 mode:
P06: wheel diameter: unit, inch; Precision: 0.1; This parameter is related to the instrument display speed and needs to be entered correctly;
P07: number of speed measuring magnetic steel: range: 1-100; This parameter is related to the instrument display speed and needs to be entered correctly;
If it is a common hub motor, directly input the number of magnetic steel;
If it is a high-speed motor, the deceleration ratio needs to be calculated, the input data = the number of magnetic steel × the deceleration ratio;
For example: motor magnetic steel number 20, reduction ratio 4.3: input data :86=20× 4.3P08: speed
limit: range 0-100km/h, 100 means no speed limit, The input data here represents the maximum running speed of the vehicle: for example, input 25 means that the maximum running speed of the vehicle will not exceed 25km/h; Drive speed is maintained at the set value, Error: ±1km/h;(Speed limit of power assist and turn handle)
Note: The value here is based on kilometers. When the unit setting is converted from kilometers to miles,
The speed value of the display interface will be automatically converted to the correct value of miles, but the speed limit data set at this menu under the mile interface will not be converted, which is inconsistent with the actual displayed speed limit value.
Note: The P09-P15 menu is only available in communication state

P09: zero start, non-zero start setting, 0: zero start;1: Non-zero start;
P10: drive mode setting 0: power drive (through the power gear to determine how much power output, at this time
The handle is invalid.
1: electric drive (through the handle drive, the power gear is invalid).
2: Power assisted drive and electric drive coexist at the same time
P11: power sensitivity setting range: 1-24;
P12: Power starting intensity setting range: 0-5;
P13: Assisted magnetic steel plate type is set to 5,8,12 magnetic steel three types
P14: The controller current limit value is set in the default range of 12A: 1-20A
P15: Undervoltage value of the controller
P16: ODO zero clearing setting Long press the key for 5 seconds
P17:0: disabled cruise, 1: enabled cruise; Automatic cruise optional (for protocol 2 only) P18: display speed proportional adjustment range: 50%~150%,
P19: The enabling bit is 0, 0: includes 0, 1: does not include 0
P20:0:2 Protocol 1: 5S Protocol 2: standby 3: standby

Four, button introduction:

1. Long press the button to switch between TRIP, VOL and TIME in shutdown state.| A key switch on; After startup,| Power button, the interface in ODO,
---|---|---
2, on the state, long press the key, power gear -1;| Key power off, short press| Key, power gear +1, short press
3, long press +| Key to enter mode Settings|

Add value,   Key to reduce the value, Key to switch to the
Save the value of the previous + Key to exit the
parameter; After modifying parameters,

Note: due to the upgrade of the company’s products, the display content of the part of the product you get may be different from the instructions, but it will not affect your normal use.