BANGGOOD H52V215 Lead Acid Battery 2-15S Lithium Battery User Guide

June 5, 2024
banggood

banggood logo

H52V215 Quick Set Two Steps

Adjust different battery types:

Press and hold the SET button for about 3 seconds to display P1. Press and hold SET again for about 3 seconds to enter the battery type selection mode. At this time, release the button and shortly press the SET button or U/D button, the voltage cycle displays 12V_3. 7V_3. 2V_2.V_1 .2V

♦12V: stands for lead-acid battery, single-cell voltage is 12V
♦3. 7V: stands for polymer lithium battery, single-cell voltage is 3. 7V
♦3. 2V: on behalf of the lithium iron phosphate battery, the single-cell voltage is 3.2V
♦2. 0V: on behalf of the lead-acid battery, the single-cell voltage is 2.0V
♦1.2V: stands for Ni-MH battery, single-cell voltage is 1.2V
♦Default display: 12V
♦ When switching to the corresponding battery type, release the button, wait until the screen flashes to save the setting, and exit the setting mode

Adjust the number of battery sections:

Press and hold the SET button for about 3 seconds to display P1, and the short SET button will switch to display P2. Press and hold SET again for about 3 seconds to enter the battery number setting mode. At this time, after releasing the button, short press the SET button to increase the value. Press the U/D key to decrease the value downward; the adjustable range of “number of cells” for different types of batteries is as follows:

♦12V lead-acid battery: 1-10 cells
♦3.7V lithium battery: 4-34 cells
♦3. 2V lithium-ion battery: 4-40 cells
♦2.0V lead-acid battery: 5-60 cells
♦1.2V inlaid hydrogen battery: 10-93 cells
♦Default display: 1
♦When switching to the corresponding battery number, release the button, wait for the screen to flash to save the setting, and exit the setting mode Non- alarm parameter adjustment menu operating instructions

Main Menu| A menu| Defaults|
---|---|---|---
P-1 (Set battery type)| 12.0 (representing a 12-cell lead-acid battery)| 12.0|
3.7 (representing a 3.7 polymer lithium battery for a single cell)| |
| 3.2 (Representing a single cell of 3.2V lithium iron phosphate battery)| |
---|---|---|---
2 (representing a single 2V lead-acid battery)| |
1-2 (representing a single cell of 1.2V Ni-MH battery)| |
P-2 (Set the number of battery cells)| 1-99 (number of battery cells)| 1| *(P-l)(P-2) <=90
P-3 (Set capacity calculation method)| P1 (normal discharge)| P1| Calculate the corresponding capacity percentage according to the internal setting interval of the program
P2 (Custom discharge interval)| | You can set the corresponding voltage value when the battery is 0% or 100%
P-4 (Custom discharge upper limit)| Corresponding voltage value when the power is 100%| 0| This value is valid only when P2 is selected in P-3 setting “Capacity calculation method”
P-5 (Custom discharge lower limit)| The corresponding voltage value when the battery is 0%| 0
P-6 (Display mode of voltage and percentage)| S1-V (Only display voltage)| |
S2-% (only the percentage is displayed)| |
S3-V% (Voltage and percentage are displayed cyclically in 4 seconds)| S3-V%|
P-7 (Charging display mode of battery bar)| 01 (Static display)| 01| During the battery charging process, the power bar dynamically displays the charging status visually
02 (dynamic display)|
P-8 (Set the brightness of the backlight)| 0/1/2/3/4| 3| When set to 0, turn off the backlight, 4 is the highest brightness
P-9 (Set energy-saving mode) )| BL (Backlight off)| BL|
DS (backlight and display are both off)| |
P10 (Set energy-saving delay time)| 0-999 (seconds) set to 0 means the backlight is always on| 15| Delayed execution time of BL/DS in F-9
P11 (Voltage fine-tuning calibration)| Voltage value fine-tuning calibration| OFF| When the displayed voltage value has a deviation, it can be adjusted within a certain range
P12 (Restore factory settings)| N0 (do not restore the default parameters)| NO| Select YES, the current parameters are all restored to the factory settings
YES (restore default parameters)**|

Operation method of button adjustment parameters:

  1. The key operation is divided into long press and short press;
    Long press: press the button for more than 3 seconds to release;
    Short press: release the button within 1 second after pressing the button;

  2. Button definition
    Short press SET (set key): switch the same level menu or adjust parameters, manually switch display voltage or display percentage
    Short press U/D (operation key): switch the menu at the same level or adjust parameters, turn off the backlight display;
    Long press SET (set key): enter the next menu
    When adjusting the value, if you need to make a large adjustment, you can press and hold the SET key or the U/D key, the displayed value will continue to increase or decrease, and the speed will gradually increase. When it is close to the set value, release the key and press again Fine-tune under

  3. Save and return the parameter value
    After 5 seconds without any key operation, the screen will flash twice to save the parameters and return to the previous menu.

Applicable battery types: ternary lithium batteries, polymer lithium batteries, lithium-ion batteries, storage batteries, water batteries and other lithium batteries, lead-acid batteries. Application: Suitable for various instruments and meters, mobile portable equipment, mobile power supplies, medical equipment, electric vehicles, balance vehicles, unicycles, etc.

BANGGOOD H52V215 Lead Acid Battery 2-15S Lithium Battery -
battery

BANGGOOD H52V215 Lead Acid Battery 2-15S Lithium Battery -
LCD

Product name| LCD liquid crystal battery indicator| Working humidity| 10~80% (no condensation)
---|---|---|---
Product number| H52V212CUP| Working pressure| 80~106kPa
Power supply| No need external power supply| Sunlight| No direct exposure
Measuring range| 9-120V (wide range)| External dimensions| 61.5×33.5×15.3mm, length x width x thickness
Minimum tidal rate| 0.1V| External opening size| Suggest 58.5×28.5mm, length x width
Error| 1% (±1 word)| Built-in external size| 64x 25 x16.8mm, length x width x thickness
Working current| <5mA (including backlight)| Built-in opening size| Recommend 43×11.3mm, length x width
Refresh rate| >=500mS/time| Lead length| 150mm
Display method| LCD liquid crystal display| Net weight| 20g
Backlight color| Green| Gross weight| 23g
Operating temperature| -10~+65℃| |