Installation Instructions

Please read all instructions prior to installation and keep for future reference!

  1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN.
    Installation Instructions

  2. USE ONLY WITH CLASS 2 POWER UNIT

  3. 24 VOLTS DC

  4. SUITABLE FOR WET LOCATIONS

  5. CATENARY MOUNT ONLY

RGB & RGBW WIRING DIAGRAM

Wiring Diagram

RGBW-PXSPI WIRING DIAGRAM

Wiring Diagram

Operation Instruction

SR-DMX-SPI
Smart Pixel LineLED Decoder

There are three buttons on the decoder:

  1. Parameter Setting

  2. Increase Value

  3. Decrease Value

NOTE:
When connected to a controller, DMX512 Signal Decoder will stay in “Decoder Mode”.

After operation, if no action was taken within 30s, the button lock, and backlight of the screen will turn off.

  1. Long press M button for 5s to unlock the buttons, and the backlight will turn on.
  2. Long press M button for 5s to switch between test mode and decode mode after unlocked.

During test mode, the first line of LCD will show: TEST MODE. Use test mode to verify RGBW Pixel functionality.
Duirng decoder mode, the first line of LCD shows: DECODER MODE. Use decoder mode when connecting to a Controller and for final installation and customization.

The second line of the LCD Display shows the current setting and value. Note: 1 Pixel = 1 Cut Increment.

MODE TABLE
SETTING LCD DISPLAY VALUE RANGE DESCRIPTION
Built-in Programs TEST MODE MODE NO.: 1-26 See Program Table below
Program Speed TEST MODE RUN SPEED: 0-7 0: fast,

7: slow
DMX Address| DECODER MODE DMX ADDRESS:| 1-512| Address of the starting point/Pixel of a program
DMX Signal RGB| DECODER MODE DMX RGB SEQ:| RGB, BGR, etc.| N/A
Pixel Quantity| DECODER MODE PIXEL QTY:| 1-170(RGB),
1-128(RGBW)| Number of Pixels to follow a program
IC TYPE| DECODER MODE IC TYPE:| **** 2903, 8903,

2904, 8904

| 2903: N/A,
2904: for RGBW,
8903: N/A,
8904: N/A
Color| DECODER MODE COLOR:| **** MONO, DUAL, RGB, RGBW| MONO: N/A, DUAL: N/A, RGB: N/A, RGBW: for RGBW
Pixel Merging / Pixel Size| DECODER MODE PIXEL MERGE:| 1-100| Number of Pixels to merge together
RGB Sequence| DECODER MODE LED RGB SEQ:| RGBW,

BGRW, etc.

| Sequence of RGBW, 24 possible combinations
Integral Control| DECODER MODE ALL CONTROL:| YES, NO| Yes: Merge all Pixels
No: Maintain individual Pixels or Merged Pixels
Reverse Control| DECODER MODE REV-CONTROL:| YES, NO| Reverse program order
Overall Brightness| DECODER MODE BRIGHTNESS:| 1-100| 1: dimmest setting 100: brightest setting

NOTE:
The actual maximum control pixels of the controller are 1360 (2903) ,1024 (2904). Please set the pixel and pixel combination value according to the actual situation, and DO NOT exceed the maximum.

PROGRAM TABLE
PROGRAM NO. PROGRAM DESCRIPTION
1 Solid color: Red
2 Solid color: Green
3 Solid color: Blue
4 Solid color: Yellow
5 Solid color: Purple
6 Solid color: Cyan
7 Solid color: White
8 RGB change
9 Full color change
10 RGB fading
--- ---
11 Full color fading
12 Red chase with trail
13 Green chase with trail
14 Blue chase with trail
15 White chase with trail
16 RGB chase with trail
17 Rainbow chase with trail
18 RGB chasing and fading
19 Red chasing green, chasing blue
--- ---
**** 20 Orange chasing purple, chasing cyan
21 Rainbow chase (7 colors)
22 Random twinkle: white over red
23 Random twinkle: white over green
24 Random twinkle: white over blue
25 White fading
26 Off

NOTE: For Program Table Change: no fading/dimming between color changes
Fade: fade/dim between color changes
Chase: change pixel by pixel
Chase with Trail: change pixel by pixel with fading between

REV0.1 10252022