BSE BSR-D5 Parking Heater User Guide
- September 11, 2024
- BSE
Table of Contents
BSR-D5 Parking Heater
“`html
Product Specifications:
- Model: AirHeaterCC
- Bluetooth Version: X.X
- Compatibility: iOS and Android
- Distance for FCC Compliance: 20 cm
Product Usage Instructions:
Connecting the Device via Bluetooth:
-
Search and download the “AirHeaterCC” app from the respective
app store. -
Turn on the Bluetooth function on your mobile phone.
-
Run the app and follow the on-screen instructions to connect
the device to your phone.
Bluetooth Connection Steps:
-
Launch the app and navigate to the Bluetooth connection
interface. -
Select the Heater + Machine code to pair the device.
-
Ensure the Bluetooth signal strength is adequate for a stable
connection. -
If the device is not found, troubleshoot by checking previous
connections and phone settings.
Setting Up Timers:
Use the app to set timers for device operation. Follow the
instructions in the app to schedule heating cycles and specific
timings.
Automatic Start-Stop Function:
The device features an automatic start-stop function. Refer to
the app for details on how to enable and customize this
functionality.
FCC Radiation Exposure Compliance:
For compliance with FCC radiation exposure limits, maintain a
minimum distance of 20 cm between the device and your body during
operation.
Frequently Asked Questions (FAQ):
Q: How do I troubleshoot if the device is not connecting via
Bluetooth?
A: Check for existing connections, ensure Bluetooth is turned
on, and follow the pairing instructions carefully.
Q: Can I control multiple devices with one phone?
A: Each device can only be connected to one phone at a time for
optimal performance.
“`
BLUETOOTH OPERATION
Search and download the corresponding app name “AirHeaterCC” in the IOS or
Android app store, or scan the QR code below with the phone and click on the
corresponding system to download, and then follow the following steps to
connect the device to the phone and control it.
[1] Option for Android [2] option for Google download [3] option for IOS
1. Turn on the Bluetooth function of the mobile phone, run the APP program
and enter the
following interface:
Note above: 1, bluetooth link keys, 2, set key, 3, bluetooth connection state,
4, equipment status and fault, 5, reduce key, 6, set gear or set temperature,
7, key, 8, working voltage, 9, altitude, 10, machine aluminum temperature, 11,
temperature around the equipment, 12, ventilation button, 13, heating button,
14, plateau button, 15, mode switch button.
2. Device connected to Bluetooth:
Press [Bluetooth Link button] to enter the page, select 1 is “Heater + Machine
code” (short press the OK button on the switch panel), 2 is the Bluetooth
signal strength (as the above figure 68, the smaller the value, the stronger
the signal). If the device is not searched, check whether any other phone has
been linked to the device (one device can only link to one phone), or then
power the device on the Bluetooth function of the phone and proceed to the
first step.
3. After the successful link, the following figure shows:
Shutdown state on state (manual mode) on state (temperature mode) 1) Boot
operation In the shutdown state, press the [heating button] to heat the
equipment, display the “startup state” as shown in the above figure, press [+]
to increase the equipment, press [-] equipment to downgrade, press [switch
mode] to switch manual / constant temperature mode (0-40 degrees), and press
the [Plateau button] button to switch the plateau / plain mode. 2) Shutdown
operation In the startup state, press the [heating button], and the device
enters the shutdown and blowing and cooling process, and displays “blowing and
cooling”. The equipment is shut down after blow cooling, showing the “shutdown
state” shown in the above. 3) Ventilation operation In the shutdown state,
press [ventilation button], turn on / off ventilation, press [+] or [-] to
adjust the fan speed.
4. Setup page description:
- Unit settings include: degrees Fahrenheit, degrees Celsius, feet, meters.
- Language Settings include: Chinese, English, Spanish, French, German,
Italy, Poland, The Netherlands, Sweden, Russian. 3) Time function includes:
Monday to Sunday, can set the open time, close time, single time and cycle
mode. 4) Automatic start-stop function: the machine is valid in constant
temperature mode after opening (some devices do not have this function). 5)
User manual includes: fault code and fault handling method.
5. Timing page description:
As shown above: [1] open button, [2] cycle execution, [3] once execution, [4] [5] device on and close time, [8] save.(The above figure is: the equipment is turned on heating at 1:14 PM on Wednesday, the equipment turns off the heating cycle at 3:16 PM on Wednesday) Note: [6] The button is on, [7] no set time, the system default time is 00:00, and the heating is not turned on when the equipment is on and off time are the same.
6. Description of the automatic start-stop function page:
As shown in the above: [1] button open, [2] select the equipment opening temperature (3-10), [3] select the equipment closing temperature (3-10), [4] save, [5] (A 37) work in automatic switch mode, the required temperature (0-40) through [+] [-] key, the temperature around [6] is the reference temperature, and [7] works automatically start and stop in constant temperature mode. The above figure shows: the setting temperature is set 37, the opening temperature is set 5, and the closing temperature is set 5. When the temperature around the equipment is 42, the equipment is stopped heating, and the equipment is turned on the heating (the timing switch function is valid at the same time).
FCC Caution. This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. Any Changes or
modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment. Note: This equipment
has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures: -Reorient or relocate the receiving antenna. -Increase the
separation between the equipment and receiver. -Connect the equipment into an
outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement: This equipment complies with FCC radiation
exposure limits set forth for an uncontrolled environment. This equipment
should be installed and operated with minimum distance 20 cm between the
radiator & your body.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>