gorenje S3 WHI643ORAW Kitchen Cooker Hood Instruction Manual
- June 3, 2024
- Gorenje
Table of Contents
FOR USE OF THE KITCHEN HOOD
DETAILED INSTRUCTIONS
S3 WHI643ORAW/S3 WHI643ORAB
S3 WHI943ORAW/S3 WHI943ORAB
S3 WHI643ORAW Kitchen Cooker Hood
|
---|---
Closely follow the instructions set out in this manual. All responsibility,
for any eventual inconveniences, damages or fires caused by not complying with
the instructions in this manual, is declined. The hood is conceived for the
suction of cooking fumes and steam and is destined only for domestic use.
The hood can look different to that illustrated in the drawings in this
booklet. The instructions for use, maintenance and installation, however,
remain the same.
- It is important to conserve this booklet for consultation at any moment. In the case of sale, cession or move, make sure it is together with the product.
- Read the instructions carefully: there is important information about installation, use and safety.
- Do not carry out electrical or mechanical variations on the product or on the discharge conduits.
- Before proceeding with the installation of the appliance verify that there are no damaged all components. Otherwise contact your dealer and do not proceed with the installation.
Note: the elements marked with the symbol “(*)” are optional accessories
supplied only with some models or elements to purchase, not supplied.
CAUTION
WARNING! Do not connect the appliance to the mains until the installation
is fully complete.
Before any cleaning or maintenance operation, disconnect hood from the mains
by removing the plug or disconnecting the mains electrical supply.
Always wear work gloves for all installation and maintenance operations.
The appliance is not intended for use by children or persons with impaired
physical, sensorial or mental faculties, or if lacking in experience or
knowledge, unless they are under supervision or have been trained in the use
of the appliance by a person responsible for their safety.
This appliance is designed to be operated by adults, children should be
monitored to ensure that they do not play with the appliance.
This appliance is designed to be operated by adults. Children should not be
allowed to tamper with the controls or play with the appliance.
Never use the hood without effectively mounted grating!
The hood must NEVER be used as a support surface unless specifically
indicated.
The premises where the appliance is installed must be sufficiently ventilated,
when the kitchen hood is used together with other gas combustion devices or
other fuels.
The ducting system for this appliance must not be connected to any existing
ventilation system which is being used for any other purpose such as
discharging exhaust fumes from appliances burning gas or other fuels.
The flaming of foods beneath the hood itself is severely prohibited.
The use of exposed flames is detrimental to the filters and may cause a fire
risk, and must therefore be avoided in all circumstances.
Any frying must be done with care in order to make sure that the oil does not
overheat and ignite. Accessible parts of the hood may became hot when used
with cooking appliance.
With regards to the technical and safety measures to be adopted for fume
discharging it is important to closely follow the regulations provided by the
local authorities.
The hood must be regularly cleaned on both the inside and outside (AT LEAST
ONCE A MONTH).
This must be completed in accordance with the maintenance instructions
provided in this manual).
Failure to follow the instructions provided in this user guide regarding the
cleaning of the hood and filters will lead to the risk of fires.
Do not use or leave the hood without the lamp correctly mounted due to the
possible risk of electric shocks.
We will not accept any responsibility for any faults, damage or fires caused
to the appliance as a result of the non-observance of the instructions
included in this manual.
This appliance is marked according to the European directive 2012/19/EC on
Waste Electrical and Electronic Equipment (WEEE). By ensuring this product is
disposed of correctly, you will help prevent potential negative consequences
for the environment and human health, which could otherwise be caused by
inappropriate waste handling of this product.
The symbol on the product, or on the documents accompanying the product,
indicates that this appliance may not be treated as household waste. Instead
it should be taken to the appropriate collection point for the recycling of
electrical and electronic equipment. Disposal must be carried out in
accordance with local environmental regulations for waste disposal.
For further detailed information regarding the process, collection and
recycling of this product, please contact the appropriate department of your
local authorities or the local department for household waste or the shop
where you purchased this product.
Appliance designed, tested and manufactured according to:
- Safety: EN/IEC 60335-1; EN/IEC 60335-2-31, EN/IEC 62233.
- Performance: EN/IEC 61591; ISO 5167-1; ISO 5167-3; ISO 5168; EN/IEC 60704-1; EN/IEC 60704-2-13; ISO 3741; EN 50564; IEC 62301.
- • EMC: EN 55014-1; CISPR 14-1; EN 55014-2; CISPR 14-2; EN/IEC 61000-3-2; EN/IEC 61000-3-3.
Suggestions for a correct use in order to reduce the environmental impact:
Switch ON the hood at minimum speed when you start cooking and kept it running
for few minutes after cooking is finished. Increase the speed only in case of
large amount of smoke and vapour and use boost speed(s) only in extreme
situations. Replace the charcoal filter(s) when necessary to maintain a good
odour reduction efficiency. Clean the grease filter(s) when necessary to
maintain a good grease filter efficiency. Use the maximum diameter of the
ducting system indicated in this manual to optimize efficiency and minimize
noise.
Additional Installation Specifications:
Use only the fixing screws supplied with the product for installation or,
if not supplied, purchase the correct screws type. Use the correct length for
the screws which are identified in the Installation Guide. In case of doubt,
consult an authorised service assistance centre or similar qualified person.
WARNING! Failure to install the screws or fixing device in accordance
with these instructions may result in electrical hazards.
USE
The hood is designed to be used either for exhausting or filter version.
Ducting version
In this case the fumes are conveyed outside of the building by means of a
special pipe connected with the connection ring located on top of the hood.
Attention! The exhausting pipe is not supplied and must be purchased
apart. Diameter of the exhausting pipe must be equal to that of the connection
ring.
In the horizontal runs the exhausting pipe must be slightly slanted (about
10°) and directed upwards to vent the air easily from the room to the outside.
Attention! If the hood is supplied with active charcoal filter, then it must
be removed.
Connect the hood and discharge holes on the walls with a diameter equivalent
to the air outlet (connection flange).
Using the tubes and discharge holes on walls with smaller dimensions will
cause a diminution of he suction performance and a drastic increase in noise.
Any responsibility in the matter is therefore declined.
- Use a duct of the minimum indispensible length.
- Use a duct with as few elbows as possible (maximum elbow angle: 90°).
- Avoid drastic changes in the duct cross-section.
- Use a duct as smooth as possible inside.
- The duct must be made of certified material.
Filter version
One active charcoal filter is needed for this and can be obtained from your
usual retailer.
The filter removes the grease and smells from the extracted air before sending
it back into the room through the upper outlet grid.
INSTALLATION
The minimum distance between the supporting surface for the cooking equipment
on the hob and the lowest part of the range hood must be not less than 50cm
from electric cookers and 65cm from gas or mixed cookers.
If the instructions for installation for the gas hob specify a greater
distance, this must be adhered to.
Electrical connection
The mains power supply must correspond to the rating indicated on the plate
situated inside the hood. If provided with a plug connect the hood to a socket
in compliance with current regulations and positioned in an accessible area,
after installation. If it not fitted with a plug (direct mains connection) or
if the plug is not located in an accessible area, after installation, apply a
double pole switch in accordance with standards which assures the complete
disconnection of the mains under conditions relating to over-current category
III, in accordance with installation instructions.
Warning! Before re-connecting the hood circuit to the mains supply and
checking the efficient function, always check that the mains cable is
correctly assembled.
The hood is provided with a special power cable ; if the cable is damaged,
request a new one from Technical Service.
Mounting
Very heavy product; hood handling and installation must be carried out by at
least two persons. Before beginning installation:
- Check that the product purchased is of a suitable size for the chosen installation area.
- Remove the charcoal (*) filter/s if supplied (see also relative paragraph). This/these is/are to be mounted only if you want lo use the hood in the filtering version.
- Check (for transport reasons) that there is no other supplied material inside the hood (e.g. packets with screws (), guarantees (), etc.), eventually removing them and keeping them.
- If possible, disconnect and move freestanding or slide-in range from cabinet opening to provide easier access to rear wall/ceiling. Otherwise put a thick, protective overing over countertop, cooktop or range to protect from damage and debris. Select a flat surface for assembling the unit. Cover that surface with a protective covering and place all canopy hood parts and hardware in it.
- In addition check whether near the installation area of the hood (in the area accessible also with the hood mounted) an electric socket is available and it is possible to connect a fumes discharge device to the outside (only suction version).
- Carry out all the masonry work necessary (e.g. installation of an electric socket and/or a hole for the passage of the discharge tube).
Expansion wall plugs are provided to secure the hood to most types of walls/ceilings. However, a qualified technician must verify suitability of the materials in accordance with the type of wall/ceiling. The wall/ceiling must be strong enough to take the weight of the hood. Do not tile, grout or silicone this appliance to the wall. Surface mounting only.
OPERATION
Use the high suction speed in cases of concentrated kitchen vapours. It is
recommended that the cooker hood suction is switched on for 5 minutes prior to
cooking and to leave in operation during cooking and for another 15 minutes
approximately after terminating cooking.
To select the functions of the hood, simply touch the controls.
T1.
Standby mode (the control panel off all functions disabled) / ON (control
panel switched on)
Note: After about a minute of inactivity (suction and lights), the hood
will automatically switch to standby.
T2. ON/OFF lights
On certain models only (see drawing above): press repeatedly to select the
desired light intensity:
L1: low light
L2: medium light
L3: high light
Press again to turn off the lights.
T3. ON/OFF Automatic operation “AdaptTech”.
The hood automatically sets the suction speed (power) 1 to increase if the
environmental conditions detected by the hood sensor require it.
If there are no variations in the environmental conditions, after 10 minutes
(if the hood is already in suction speed (power) 1), the hood turns off.
Note: for a correct use of this function, first perform the “Setting of
the parameters for Automatic Operation” (see corresponding paragraph).
Note: During automatic operation, if the user acts on the other functions
that adjust the speed, auto ventilation function is switched off.
T4. Manual selection of the suction speed (power):
L4: suction speed (power) 1
L5: suction speed (power) 2
L6: suction speed (power) 3
Press again to turn off the hood (OFF).
Note: manual selection excludes any other suction related set function.
T5.
ON/OFF Intensive suction speed (power) „POWER BOOST” (timed)
Note: After 5 minutes of operation the hood returns to its previous
state.
*T6.
(Only certain models ON/OFF intensive suction speed (power) „POWER BOOST x 2”
(timed)
Note: After 5 minutes of operation, the hood goes back to the previous
status.
T7.
ON/OFF operation mode “Refresh”.
Every 50 minutes of inactivity, the suction speed (power 1 is turned on for 10
minutes.
T8.
ON/OFF Delayed switch off of the suction speed (power) (approx. 30 minutes
Note: this function is available for the speeds that can be selected with
button T4.
T9.
Indicator and reset filter saturation
The button lights on automatically with steady light when it is necessary to
perform the grease filter maintenance. The button lights on automatically with
flashing light when it is necessary to perform the charcoal filter
maintenance.
After performing the maintenance, with the hood off and the button active,
press the button for more than 3 seconds to perform the reset of the filter
saturation indicator; repeat the operation if necessary (for ex., when both
filters are saturated).
Activation of the charcoal filter saturation indicator
The saturation indicator of the charcoal filter is normally disabled. To
activate it, proceed in the following manner:
With the display on (ON) and the suction off (OFF), press simultaneously the
buttons T8 and T9 for more than 3 seconds; the button T9 lights on with steady
light for approx. 5 seconds, to indicate the activation.
To disable it, repeat the operation; the button T9 will flash for approx. 5
seconds to indicate the disabling.
Setting of Automatic Operation parameters
For correct use of the automatic operation, perform “Hood Calibration”.
Hood Calibration
With the display on (ON) and the suction off (OFF), press button T3 for 3
seconds.
The suction speed (power) 1 starts functioning and button T3 flashes to
indicate that hood calibration is initiated and it will last for approx. 5
minutes.
Note:** to interrupt the calibration, press T3 for 5 seconds; the
calibration will be invalidated and should therefore be repeated.
MAINTENANCE
ATTENTION! Before performing any maintenance operation, isolate the hood
from the electrical supply by switching off at the connector and removing the
connector fuse.
Or if the appliance has been connected through a plug and socket, then the
plug must be removed from the socket.
Cleaning
The cooker hood should be cleaned regularly (at least with the same frequency
with which you carry out maintenance of the fat filters) internally and
externally. Clean using the cloth dampened with neutral liquid detergent. Do
not use abrasive products. DO NOT USE ALCOHOL!
WARNING: Failure to carry out the basic cleaning recommendations of the
cooker hood and replacement of the filters may cause fire risks. Therefore, we
recommend observing these instructions. The manufacturer declines all
responsibility for any damage to the motor or any fire damage linked to
inappropriate maintenance or failure to observe the above safety
recommendations.
Grease filter
Traps cooking grease particles. The grease filter must be cleaned once a month
using non aggressive detergents, either by hand or in the dishwasher, which
must be set to a low temperature and a short cycle. When washed in a
dishwasher, the grease filter may discolour slightly, but this does not affect
its filtering capacity. To remove the grease filter, pull the spring release
handle.
Charcoal filter (filter version only)
It absorbs unpleasant odours caused by cooking. The saturation of the charcoal
filter occurs after more or less prolonged use, depending on the type of
cooking and the regularity of cleaning of the grease filter. In any case it is
necessary to replace the cartridge at least every four mounths.
Replacing lamps
The hood is equipped with a lighting system based on LED technology. The
LEDs guarantee an optimum lighting, a duration up to 10 times as long as the
traditional lamps and allow to save 90% electrical energy.
For replacement, contact the technical service.
Documents / Resources
|
gorenje S3 WHI643ORAW Kitchen Cooker
Hood
[pdf] Instruction Manual
S3 WHI643ORAW, S3 WHI643ORAB, S3 WHI943ORAW, S3 WHI943ORAB, S3 WHI643ORAW
Kitchen Cooker Hood, Kitchen Cooker Hood, Cooker Hood
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>