luminii LETO 44 Mini P 954 Semi-Recessed Canopy Installation Guide
- June 3, 2024
- luminii
Table of Contents
luminii LETO 44 Mini P 954 Semi-Recessed Canopy
Read and follow these instructions before installing or maintaining this product
- This product is suitable for DRY INDOOR LOCATIONS ONLY
- Make sure this product is NOT on the same circuit as inductive loads, (e.g. fluorescent bulbs, discharge bulbs, ventilation fans, etc…)
- Do not switch on line voltage until all wiring is complete
- Incorrect wiring will result in irreparable damage to LED and power supply
- This product should only be installed by a licensed electrician
Warranty
- This product must be installed in accordance with all applicable installation codes and ordinance.
- Limited five (5) years warranty · Warranty is void in the eventuality of unauthorized modifications and/or improper use
INSTALLATION INSTRUCTION
Pendant: Single Feed Cable (AC Connection)
-
Finish ceiling installation. Make sure hole is cut to appropriate size and location. 54mm (2.125”)
-
Disassemble driver housing to expose the driver.
-
Make electrical connections and use appropriate strain relief.
-
Reassemble housing and insert into ceiling. Push aside to leave room for canopy
-
Connect dimming controls to included cable clamps. Insert wires and canopy into ceiling.
-
Turn screws until housing is secured in place (arms will rotate and clamp down on ceiling)
-
Unscrew gripper plate and separate from canopy.
-
Unscrew gripper plate and separate from canopy
-
Re-attach gripper to canopy and slide trim plate up until held in place by magnets.
Pendant: Single Feed Cable (Remote DC Connection)
-
Finish ceiling installation. Make sure hole is cut to appropriate size and location. 54mm (2.125”)
-
Disassemble driver housing to expose fixture wiring. Cylinder housing is used as DC junction box.
-
Make electrical connections and use appropriate strain relief.
-
Reassemble housing and insert into ceiling. Push aside to leave room for canopy.
-
Insert canopy into ceiling.
-
Turn screws until housing is secured in place (arms will extend and clamp down on ceiling)
-
Unscrew gripper plate and separate from canopy.
-
Loosen set screw and adjust cable to desired height. Cut and reconnect wire if needed.
-
Re-attach gripper to canopy and slide trim plate up until held in place by magnets.
Pendant: Powered Aircraft Cable (Remote DC Connection)
-
Finish ceiling installation. Make sure hole is cut to appropriate size and location. 54mm (2.125”)
-
Disassemble driver housing to expose the driver.
-
Make electrical connections and use appropriate strain relief.
-
Reassemble housing and insert into ceiling. Push aside to leave room for canopy.
-
Connect dimming controls to included cable clamps. Insert wires and canopy into ceiling.
-
Turn screws until housing is secured in place (arms will extend and clamp down on ceiling)
-
Slide trim plate up until held in place by magnets.
Pendant: Powered Aircraft Cable (Remote DC Connection)
-
Finish ceiling installation. Make sure hole is cut to appropriate size and location. 54mm (2.125”)
-
Disassemble driver housing to expose fixture wiring. Cylinder housing is used as DC junction box.
-
Make electrical connections and use appropriate strain relief
-
Reassemble housing and insert into ceiling. Push aside to leave room for canopy
-
Insert canopy into ceiling
-
Turn screws until housing is secured in place (arms will extend and clamp down on ceiling)
-
Slide trim plate up until held in place by magnets
Pendant: Powered Aircraft Cable (Remote DC Connection)
-
Remove trim plate from the canopy
-
Unscrew gripper plate separate from canopy.
-
Loosen set screw and adjust cable to desired height.
-
Cut excess cable leaving ~3” above gripper. Make electrical connections using appropriate hardware
-
If cables develop a twist, loosen set screw and cycle cable through the gripper 4-5 times.
-
Tighten screws, re-attach gripper plate to canopy and slide trim plate up until held in place by magnets.