PDQ 6W199 Electrified Exit Device Trim Instruction Manual

June 4, 2024
PDQ

  6W199 Electrified Exit Device Trim

INSTALLATION INSTRUCTIONS

Phone: 833-2-PDQTEC | www.pdqlocks.com


1. REMOVE HEAD COVER AND RAIL FILLER PLATE
  • Remove (4) screws, push latch into device to remove head cover

PDQ 6W199 Electrified Exit Device Trim 1

  1. RAIL FILLER PLATE
  2. HEAD COVER
2. REMOVE HOLDING SCREW AND RAIL
  • Remove screw securing backplate to rail
  • Remove backplate from rail
  1. HOLDING SCREW
  2. RAIL
3. INSTALL WIRE SADDLES ONTO BACKPLATE
  • Secure (3) wire saddles to backplate

PDQ 6W199 Electrified Exit Device Trim 3

A (3) Mounting Locations

4. CONFIGURE TRIM FOR FAIL SAFE OR FAIL SECURE
  • Fail Secure: Power to Unlock (Default)
    • Outside trim is locked when power is OFF, and unlocked when power is ON

  • Fail Safe: Power to Lock (Cut White Loop)
    • Outside trim is locked when power is ON, and unlocked when power is OFF.

  1. POWER WIRES ARE BLUE OR YELLOW
  2. WHITE LOOP
5. INSTALL TRIM AND DEVICE
  • Refer to trim and exit device installation instructions and templates.
  • For ISMC option only:
    • Install nonpolar blue or yellow power wires into positions 1 & 2 on housing
    • If REX and/or LM option is selected, install wires in existing housing on exit device. Otherwise, install wires in provided 8-pin housing

PDQ 6W199 Electrified Exit Device Trim 5

A ISMC OPTION:
TERMINAL INSERTION
END SHOWN

ELECTRICAL SPECIFICATIONS

Keep operating voltage at +/- 10% of rated voltage

Vin Max Inrush Current Standby Current
12-24 VDC 1.0A 5mA
12-24 VAC 1.0A 15mA

Important Notes:
Power must be applied to lock for a minimum of 5 seconds. It may be necessary to adjust the default time delay on your system. Device may not lock reliably if powered for less than 5 seconds

To convert from fail secure to fail safe, cut the white wire loop. No need to cover the cut wires. To revert to fail secure, reconnect the white wires with a suitable wire nut for two 24AWG wires.

Kit includes components to safely route wires through 6300/6400 exit device. Failure to use this kit will result in pinched wires.

639412 Rev0 – 3-21-22