LUMEX US0208 Homecare Bed User Manual

September 27, 2024
LUMEX

US0208 Homecare Bed

Product Information

Specifications

  • Models: US0208 / US0208PL (Semi-Electric Bed), US0458 /
    US0458PL (Full-Electric / Low Bed)

  • Thermal motor protection

  • Gravity-down feature for head and knee elevation

Product Usage Instructions

Safety

The safety statements provided in the manual are crucial for the
operator to follow to ensure safe usage of the Patriot Homecare
Bed. Pay close attention to all safety warnings and cautions
mentioned throughout the manual.

Introduction

The Patriot Homecare Bed user manual provides detailed
information on the features and operation of the bed. It includes
thermal motor protection and a gravity-down feature for head and
knee elevation.

Maintenance and Safety Checks

Regular maintenance and safety checks are essential to keep the
bed in optimal working condition. Refer to the manual for detailed
instructions on maintenance procedures and safety checks.

Limited Warranty

The Patriot Homecare Bed comes with a limited warranty. Refer to
the warranty section in the manual for information on coverage and
terms.

FAQ

Q: Where can I find the most updated information on the

product?

A: For the latest information on packaging, warranties,
products, and specifications, visit our website at
www.grahamfield.com.

PATRIOT US0208 / US0208PL SEMI-ELECTRIC BED US0458 / US0458PL
FULL-ELECTRIC / LOW BED USER MANUAL
SAVE THIS MANUAL FOR FUTURE USE.
US0208-INS-LAB-RevF23

CONTENTS
1 SAFETY ……………………………………………………………………………………………………………………………………………………………………….. 3 WARNING / CAUTION / NOTICE SUMMARY……………………………………………………………………………………………………………. 3
2 INTRODUCTION, PATRIOT HOMECARE BED USER MANUAL………………………………………………………………………………………… 5 THERMAL MOTOR PROTECTION …………………………………………………………………………………………………………………………… 5 GRAVITY-DOWN FEATURE FOR HEAD AND KNEE ELEVATION ……………………………………………………………………………….. 5
3 ASSEMBLY INSTRUCTIONS………………………………………………………………………………………………………………………………………….. 6 HEAD AND FOOT ASSEMBLY …………………………………………………………………………………………………………………………………. 6 MOTOR ASSEMBLY ……………………………………………………………………………………………………………………………………………….. 7 REMOVE MOTOR SLIDE CAPS ………………………………………………………………………………………………………………………… 7 INSTALL MOTORS …………………………………………………………………………………………………………………………………………… 7 INSTALL MOTOR SLIDE CAPS …………………………………………………………………………………………………………………………. 8 MOTOR ASSEMBLY TROUBLESHOOTING ……………………………………………………………………………………………………….. 8 FULL- ELECTRIC BED ONLY (US0458 / US0458PL): CASTER POSITION……………………………………………………………………. 8 STANDARD (CONVENTIONAL) BED HEIGHT …………………………………………………………………………………………………….. 8 LOW BED HEIGHT …………………………………………………………………………………………………………………………………………… 8 BED END ASSEMBLY……………………………………………………………………………………………………………………………………………… 9 ALL BED MODELS: ASSEMBLE BED HEAD END ………………………………………………………………………………………………. 9 ALL MODELS: ASSEMBLE BED FOOT END………………………………………………………………………………………………………. 9 ALL MODELS: INSTALL BED END LOCKING HARDWARE ……………………………………………………………………………….. 10 FULL-ELECTRIC BED ONLY (US0458 / US0458PL): ASSEMBLE HI/LO MOTOR SHAFT TO FOOT END GEAR BOX12 HI/LO ROD ASSEMBLY / BED LENGTH …………………………………………………………………………………………………………………. 13 SEMI-ELECTRIC BED ONLY (US0208 / US0208PL): ASSEMBLE HI/LO ROD……………………………………………………… 13 FULL-ELECTRIC BED ONLY (US0458 / US0458PL): ASSEMBLE HI/LO ROD……………………………………………………… 13 ALL MODELS: ATTACH HI/LO ROD TO GEARBOX OR MOTOR SHAFT PINS ……………………………………………………. 14
4 BED OPERATION………………………………………………………………………………………………………………………………………………………… 15 PENDANT HAND CONTROL OPERATION ……………………………………………………………………………………………………………… 15 SEMI-ELECTRIC BED ONLY (US0208 / US0208PL) ………………………………………………………………………………………….. 15 FULL-ELECTRIC BED ONLY (US0458 / US0458PL) ………………………………………………………………………………………….. 15 CRANK OPERATION: SEMI- ELECTRIC BED ONLY (US0208 / US0208PL)………………………………………………………………… 16 TRENDELENBURG POSITION, ALL MODELS ………………………………………………………………………………………………………… 16 REVERSE TRENDELENBURG POSITION, ALL MODELS ………………………………………………………………………………………… 16
5 SPECIFICATIONS, ALL MODELS …………………………………………………………………………………………………………………………………. 17
6 ACCESSORIES: BED RAILS ………………………………………………………………………………………………………………………………………… 18 PATRIOT LIBERTY BED RAIL DESIGN …………………………………………………………………………………………………………………… 19 GF6580BH-1: QUARTER RAIL…………………………………………………………………………………………………………………………. 19 GF6590BH-1: HALF NO-GAP HEAD RAIL ………………………………………………………………………………………………………… 20 GF6570B-1: FULL LENGTH RAIL …………………………………………………………………………………………………………………….. 20 LUMEX UNIVERSAL BED RAILS……………………………………………………………………………………………………………………………. 21 GF6570A-1: FULL LENGTH SIDE RAIL…………………………………………………………………………………………………………….. 21
7 SERVICE PARTS, ALL MODELS…………………………………………………………………………………………………………………………………… 22 BED COMPONENTS……………………………………………………………………………………………………………………………………………… 22 BED END COMPONENTS……………………………………………………………………………………………………………………………………… 23 BED SERVICE PARTS …………………………………………………………………………………………………………………………………………… 24
8 MAINTENANCE AND SAFETY CHECKS……………………………………………………………………………………………………………………….. 25
9 LIMITED WARRANTY ………………………………………………………………………………………………………………………………………………….. 26
10 INDEX ………………………………………………………………………………………………………………………………………………………………………… 27

GF Health Products, Inc. (“Graham-Field”) is not responsible for typographical errors. For the most updated and current information on packaging, warranties, products and specifications, including the most current version of these instructions, please visit our website at www.grahamfield.com.
Graham-Field and Lumex are registered trademarks, and Patriot is a trademark, of GF Health
Products, Inc.

US0208-INS-LAB-RevF23

www.grahamfield.com

2

1 SAFETY
The safety statements presented in this chapter refer to the basic safety information that the operator of the Patriot Homecare Bed shall pay attention to and abide by. There are additional safety statements in other chapters or sections, which may be the same as or similar to the following, or specific to the operations. Please note the following special statements, used throughout this manual, and their significance:
WARNING: Indicates a potential hazard situation or unsafe practice that, if not avoided, could result in death or serious personal injury. CAUTION: Indicates a potential hazard situation or unsafe practice that, if not avoided, could result in moderate or minor personal injury. s NOTICE: Indicates a potential hazard or unsafe practice that, if not avoided, could result in product or property damage.
Info: Provides application recommendations or other useful information to ensure that you get the most from your product.
WARNING / CAUTION / NOTICE SUMMARY
WARNING: To Reduce the Risk of Burns, Fire, Electric Shock, or Personal Injury:
WARNING: Keep hands and feet clear of all moving parts. WARNING: Do not allow small children on or near bed during operation. WARNING: Do not allow this device to be operated by small children. WARNING: When operating the hi/lo, knee, or back function of the bed, ALWAYS ensure that the individual confined to the bed is positioned properly within the confines of the bed. DO NOT let any extremities protrude over the side or between the bed rails when performing any functions. WARNING: Under normal operating conditions, this product has a maximum weight capacity of 450 lb, EVENLY DISTRIBUTED, including mattress, accessories, rails, etc. This product has a maximum patient weight capacity of 350 lb, EVENLY DISTRIBUTED. Ensure that body weight is evenly distributed over the surface of the bed. Do not lie, sit or lean in such a way that your entire body weight is placed only on the raised head or foot sections of the bed. This includes when assisting the user in repositioning or transferring in or out of bed. WARNING: In order not to invalidate the warranty or create a hazardous condition resulting in serious personal injury, GF Health Products, Inc. (“GF”) -recommends the use of only Lumex replacement parts. WARNING: Before operating, ensure that the bed frame rivets are properly seated in the bed end hooks; otherwise, personal injury or damage could result. WARNING: Keep all moving parts free of obstructions (i.e. blankets/sheets, heating blankets/pads, tubing, wiring, and other types of products). WARNING: Ensure that Bed End Locking Hardware is installed in order to prevent personal injury when moving the bed or using a bed-mount trapeze. WARNING: WARNING/CAUTION labels applied to the bed outline hazards or unsafe practices that could result in personal injury and/or property damage; do not remove them. WARNING: Ensure that the power cord DOES NOT get tangled around the bed, bed rails or legs during normal operation of the bed.
WARNING: Do not leave the bed unattended when plugged in.
WARNING: GF Health Products, Inc. assumes no responsibility for any damage or injury caused by improper assembly or use of this product.

US0208-INS-LAB-RevF23

www.grahamfield.com

3

WARNING: GF Health Products, Inc. specifically disclaims responsibility for any bodily
injury or property damage which may occur during any use which does not comply with federal, state or local laws or ordinances.
NOTICE: To Reduce the Risk of Product or Property Damage:
s NOTICE: The pendant hand control cord must be routed and secured properly to ensure that the cord does NOT become entangled and eventually severed during use.
s NOTICE: When using nasal or masked type administering equipment, oxygen or air tubing MUST be routed and secured properly to ensure that tubing does NOT become entangled and eventually severed during normal operation of bed.

US0208-INS-LAB-RevF23

www.grahamfield.com

4

2 INTRODUCTION, PATRIOT HOMECARE BED USER MANUAL
This manual contains assembly and maintenance instructions for your Model US0208 / US0208PL Semi-Electric and US0458 / US0458PL Full-Electric / Low Patriot bed. Read the entire manual carefully before using your bed, and refer to it during use if you have questions.
THERMAL MOTOR PROTECTION This product is powered by a quiet, efficient DC motor system. When the bed is plugged into a power outlet, the electrical transformer is always energized in a stand-by condition. The Okimat actuator casing may feel warm to the touch even when the bed is not being used; this is a normal condition.
Thermal protection activation (protection against overheating caused by excessive or extended periods of operation), which causes the bed to shut down operation when overheated, is a safety feature of this product. Causes of thermal protection activation include multiple or repeated adjustment of long duration, or the use of multiple functions at one time. To ensure trouble-free operation, always allow a slight pause between multiple adjustments, and avoid operating more than one function at a time. If thermal protection activation occurs, the bed pendant hand control will not function. The thermal protection will reset after a period of time dependent on the severity of the overheating. To shorten the reset time, temporarily unplug the power cord from the power outlet.
GRAVITY-DOWN FEATURE FOR HEAD AND KNEE ELEVATION
Patriot beds are equipped with a gravity-down safety feature. The motors push the head and knee grid decks up, but do not pull the knee and head down. As the motor plunger retracts, the head and knee lower freely, minimizing bed damage and/or personal injury from items caught under the grid deck.
Info: When using telescoping deck-mount bed rails, the head and knee may not lower without weight on the bed.

US0208-INS-LAB-RevF23

www.grahamfield.com

5

3 ASSEMBLY INSTRUCTIONS

HEAD AND FOOT ASSEMBLY

foot section

hook

rivet
motor cam head section

Head Foot

hook rivet
Assembly, head and foot sections Note: Grid deck not shown for clarity
1. Place the head and foot sections on their sides at approximately right angles to each other with motor cams up, as shown above.
2. Slide the head and foot sections together until the foot section’s hook catches the head section’s rivet on both sides. Ensure both rivets are completely seated before continuing.

linkage plate

head wing

head
foot
straighten
Straighten sections Note: Grid deck not shown for clarity
3. With the rivets fully seated in the hooks as described in step 2, rotate and straighten the bed as shown above. Position head wing as shown above.
s NOTICE: While balancing the frame, do not elevate the knee too far or the linkage may overextend and lock. If the linkage locks, manually push the large linkage plate toward the foot of the bed.

US0208-INS-LAB-RevF23

www.grahamfield.com

6

MOTOR ASSEMBLY
WARNING: Assemble motor on bed as follows. While it is possible to install the motor backwards, avoid it! Incorrect installation could cause the bed to move in unexpected ways. Note that the motor ends are labeled and embossed with head and foot symbols (shown at right). Ensure that bed head and motor head, and bed foot and motor foot, are matched.
Remove motor slide caps

pressure

slide cap

motor Install motor slide caps
slide cap

motor Remove motor slide caps

1. Remove the slide caps from both ends of the motor as shown above. Plungers should be recessed in motor cavities; if not, plug the power cord into any grounded outlet and operate “down” function on the pendant hand control, then unplug the power cord.
Info: Motor comes from factory with pendant hand control plugged into motor.
2. Install 9V backup battery (not provided) and slide into storage area.

Install Motors

cam head

foot

Install motor

tap here

3. Hold the bed securely, positioned with motor cams up, as shown above. 4. Position the motor over both cams. 5. Tap either end of the motor housing (shown below) with enough force to snap the motor
assembly into position on the cam. 6. Repeat step 5 for other end of motor.

US0208-INS-LAB-RevF23

www.grahamfield.com

7

Install motor slide caps
7. Position the caps as shown at right so that the grooves in the slide cap are aligned with the grooves in the motor.
8. Apply straight downward pressure to each end of the cap while sliding into the closed position.
9. Repeat step 8 for the other cap. 10. Ensure that all four corners of each slide cap are engaged.

WARNING: Ensure that the motor is assembled on bed as instructed above before use.

Motor assembly troubleshooting Problems associated with improper motor installation are listed below, with appropriate fix.

Problem
Head operates with knee control button and knee operates with head control button
Knee lifting linkages bind against grid deck, preventing knee deck from elevating.

Probable cause Motor is installed backwards

Fix
Remove motor and reverse it (see previous page)

Motor is installed backwards, enabling Remove motor and reverse it (see

knee to elevate too high and bind

previous page)

linkage

FULL-ELECTRIC BED ONLY (US0458 / US0458PL): CASTER POSITION
Any full-electric Patriot bed can be used as either a standard-height or low- height bed by moving the casters.

fig 1: casters mounted at standard height

fig 2: casters mounted at low height, bed in lowest position

fig 3: casters mounted at low height, bed in elevated position

Standard (conventional) bed height To achieve standard bed height, insert casters into outside legs, as shown in fig. 1 above.
Low bed height To achieve low bed height, insert casters into inner short legs, as shown in figs. 2 and 3 above. When in the lowest position, the casters are engaged for bed movement, as shown in fig. 2 above. When elevated, the bed is off the casters and cannot be moved, as shown in fig. 3 above. Due to the clearances involved, only minor travel and movement are recommended in the low position. The casters can be moved to the outer legs to provide clearance if the bed must be moved or rolled.

US0208-INS-LAB-RevF23

www.grahamfield.com

8

BED END ASSEMBLY All bed models: Assemble bed head end 1. Insert one locking and one non-locking caster into bed end. Locking casters must be
installed diagonally from each other. See previous page for full-electric caster position options. 2. Standing directly in front of the bed end, position it as close to the bed as possible. 3. With one hand, reach over end and lift up the bed.
bed head end frame (head)
Attach bed head end
4. Tilt the bed end slightly back toward you as shown above.

rivet lock

Engage lower rivet

Lower bed onto lock

5. Engage lower rivet slightly with corner lock and tilt end toward bed as shown at above left. 6. Lower bed onto corner lock as shown at above right. All models: Assemble bed foot end
After bed head end has been attached, perform steps 1-6 in All models: Assemble bed head end above to install the foot end.

US0208-INS-LAB-RevF23

www.grahamfield.com

9

All models: Install bed end locking hardware

1. After bed head end has been attached, install Bed End Locking Hardware to act as a latch for each corner.
Bed End Locking Hardware, part number 690-1000-100, includes four lanyards, each assembled from a clevis pin, hairpin clip, fender washer, and nylon cord, as shown at right. Bed end locking hardware, while not necessary for normal bed operation, will prevent the bed ends from accidentally rolling off when moving or pushing the bed, or while installing or using bed-mount trapezes.

fender washer
clevis pin with hole

nylon cord
hairpin clip Lanyard

WARNING: GF Health Products, Inc. recommends the use of Bed End Locking Hardware at all times.

bed end

frame

bracket

lanyard —

hairpin clip

bed end

removed

bracket

a

b

c

(corner lock)

2. Refer to accompanying illustrations while installing Bed End Locking Hardware. Remove the hairpin clip from the end of the lanyard assembly, as shown in a, and set it aside.
3. Align the cord end with the frame bracket top hole closest to the bed end. Insert the cord end through the hole so that an equal amount of cord extends outside either side of the frame bracket hole, as shown in b.
4. The lanyard assembly will now hang loosely with the clevis pin and fender washer end on the outside, as shown in c.

US0208-INS-LAB-RevF23

www.grahamfield.com

10

d

e

f

5. From the inside, reattach the hairpin clip to the cord’s looped end as shown in d. This prevents the cord from slipping back through the frame bracket hole.
6. From the outside, insert lanyard clevis pin with washer into the small hole directly below the bed end bracket top hook so that the washer rests against the bracket, as shown in e.
7. From the inside, insert the hairpin clip, now attached to the cord, into the clevis pin hole to secure, as shown in f.
8. Follow previous steps 1-7 for other bed end corners, ensuring that all four corners are securely fastened and locked in place.

US0208-INS-LAB-RevF23

www.grahamfield.com

11

Full-electric bed only (US0458 / US0458PL): Assemble hi/lo motor shaft to foot end gear box

FOOT END
notches in hi/lo motor shaft coupler slide over gear box shaft pin

hi/lo motor

gear box hi/lo motor shaft
Attach hi/lo motor shaft to foot end gear box
You must first attach the coupler end of the motor shaft to the foot-end gear box (see above). 1. Note the position of the hi/lo motor plug on the Okimat actuator next to the pendant hand
control plug — plug the hi/lo motor into the actuator, routing the hi/lo motor cord under the fixed base frame cross-angle as shown below to ensure clearance with the hi/lo drive shaft. 2. Plug the power cord into any grounded outlet. 3. Pull the motor shaft toward the foot end. Using the hi/lo function on your pendant hand control, slowly turn the hi/lo motor shaft until the coupler matches up with the gear box shaft pin as shown above. 4. Slide the coupler until it rests completely on the pin. You may need to manipulate the foot end slightly from side to side and/or lift the hi/lo motor itself for proper alignment. 5. Unplug the power cord. WARNING: Ensure power cord is unplugged before performing further bed assembly.
HEAD
FOOT

Route cord under cross-angle

US0208-INS-LAB-RevF23

www.grahamfield.com

12

HI/LO ROD ASSEMBLY / BED LENGTH
The hi/lo rod assembly consists of an inner and outer tube with a spring button lock to keep them together. 1. Assemble outer and inner tubes: Semi- electric bed only (US0208 / US0208PL): Assemble hi/lo rod
Hi/lo rod assembly semi-electric bed US0208 / US0208PL spring button inner tube outer tube
inserted spring button position
Depress spring button and insert inner tube into outer tube until third hole is reached as shown above. Release spring button to lock it into hole. Full- electric bed only (US0458 / US0458PL): Assemble hi/lo rod

spring button

Hi/lo rod assembly full-electric bed
US0458 / US0458PL

inner tube outer tube

inserted spring button position

Depress spring button and insert inner tube into outer tube until first hole of second hole set is reached as shown above. Release spring button to lock it into hole.

US0208-INS-LAB-RevF23

www.grahamfield.com

13

All models: Attach hi/lo rod to gearbox or motor shaft pins Both ends of the hi/lo rod assembly have a slot to mount on the foot end motor shaft pins and bed end gearbox shaft pins. Follow steps 2-3 to mount the hi/lo rod assembly on the gearboxes.
notch at end of hi/lo rod rests over pin at end of motor shaft

foot end
foot end gearbox Fig 1: Semi-Electric Bed: Attach hi/lo rod assembly
to foot end gearbox

FOOT END

head end

end of hi/lo rod (notch)
end of hi/lo motor shaft
Fig 2: Full-Electric Bed: Attach hi/lo rod assembly to foot end hi/lo motor shaft

head end gearbox
Fig 3: All Bed Models: Attach hi/lo rod assembly
to head end gearbox

2. Connect the hi/lo rod assembly to the bed. Semi-electric bed: Attach either end of hi/lo rod assembly to the foot end gearbox as shown in Fig 1 above. Full-electric bed: Attach either end of hi/lo rod assembly to the foot end hi/lo motor shaft as shown in Fig 2 above.
3. Attach other end of hi/lo rod assembly to head end gearbox as shown in Fig 3 above.

US0208-INS-LAB-RevF23

www.grahamfield.com

14

4 BED OPERATION
WARNING: Ensure that bed is secure and assembled as instructed on previous pages before operating. Plug the power cord into any grounded outlet. WARNING: Do not leave the bed unattended when plugged in. Info: In the event of a power failure, use a standard 9V battery to lower the bed’s head and foot sections (the 9V battery connection is attached to the motor). When used with the battery, the motor will only lower, not lift, the head and/or foot sections.
PENDANT HAND CONTROL OPERATION

Semi-electric bed only (US0208 / US0208PL)
The semi-electric pendant hand control is shown at right. Use the pendant hand control to raise and lower bed head and foot. Each button has a different function, as noted in the picture.

to raise head
to lower head and foot at the
same time
to lower head

to raise foot
to raise head and foot at the same time
to lower foot

Full-electric bed only (US0458 / US0458PL)
The full-electric pendant hand control is shown at right. Use the pendant hand control to raise and lower bed, head and foot. Each button has a different function, as noted in the picture.

Semi-electric pendant hand control

to raise head to raise foot to raise bed

to lower head to lower foot to lower bed

US0208-INS-LAB-RevF23

Full-electric pendant hand control

www.grahamfield.com

15

CRANK OPERATION: SEMI-ELECTRIC BED ONLY (US0208 / US0208PL)

Use the crank at the center foot of the semi-

foot

electric bed (shown at right) to change bed

height (raise or lower entire deck).

crank Crank operation
TRENDELENBURG POSITION, ALL MODELS (HEAD END AT LOWER ELEVATION THAN FOOT END)

  1. Lower bed to its lowest height. Disengage the hi/lo rod by compressing the spring button and
    removing the hi/lo rod from the motor or bed end. 2. Raise the foot bed end using the pendant hand control or crank (semi-electric bed only). The
    head end will remain in the low position.
    REVERSE TRENDELENBURG POSITION, ALL MODELS (HEAD END AT HIGHER ELEVATION THAN FOOT END) 1. Raise bed to its highest height. Disengage the hi/lo rod by compressing the spring button and
    removing the hi/lo rod from the motor or bed end. 2. Lower the foot bed end using the pendant hand control or crank (semi-electric bed only). The
    head end will remain in the high position.

US0208-INS-LAB-RevF23

www.grahamfield.com

16

5 SPECIFICATIONS, ALL MODELS
Deck height High position

Deck height: High Position

Low position

US0208 / US0208PL: 24.0 inches

US0458 / US0458PL with US0458 / US0458PL

casters in low position: with casters in standard

20.0 inches

position: 23.5 inches

Deck height: Low Position

Bed length Info: To extend grid length (80 in.) to 84 in., install optional kit 6900084-000 (all beds).
Deck width

US0208 / US0208PL: 15.0 inches
All models: 87.0 inches

US0458 / US0458PL with US0458 / US0458PL

casters in low position: with casters in standard

9.5 inches

position: 13 inches

Bed Length

Deck Width

Weight Construction Finish
US0208-INS-LAB-RevF23

All models: 36.0 inches

Normal operating conditions

450 lb, EVENLY DISTRIBUTED including mattress, accessories, rails, etc.

Maximum patient weight

350 lb, EVENLY DISTRIBUTED

Frame

10 ga (.135) high strength, low alloy steel (roll formed)

Sleeping surface

11 ga (.120) cold rolled steel

5 stage bath

1. S21F acid bath (cleans grease and oil from metal).

2. Fresh water rinse.

3. QuiliPhos 20 phosphate coat (inhibits rust and helps maintain electrical charge during powder application).

4. Fresh water rinse.

5. QuiliRinse 404 (seals metal for powder coating).

All parts are then coated with a colored epoxy powder and baked 35 minutes at 375 degrees F. The powder coating finish is approximately 2.5 mils thick. The coating is smooth, uniform finish without runs, wrinkles, or grit.

www.grahamfield.com

17

6 ACCESSORIES: BED RAILS
Patriot Homecare Bed decks are equipped with patent-pending slots specifically for bed rail installation, providing a fixed place to mount GF bed rails. Two styles of Lumex bed rails are described in Section 6:

  1. The Lumex Patriot Liberty bed rail system, designed specifically for Patriot Beds, and 2) The Lumex Universal bed rail system
    WARNING: Please read the following bed rail safety information before attaching and
    using your rails. Bed Rail Safety
    WARNING: If bed rails are not properly installed and adjusted, personal injury and / or
    damage to the bed rail could result. Please read and understand the following bed rail decal before use:
    For information on Bed Rail safety, please see the FDA’s brochure concerning Bed Safety and Bed Rails on the FDA website, at:
    www.fda.gov/MedicalDevices/ProductsandMedicalProcedures/GeneralHospitalDevicesandSupplies/ HospitalBeds/
    WARNING: Patient entrapment with bed side rails may result in serious injury or death.
    Use only with coherent patients capable of avoiding entrapment. Patients at risk of entrapment include those who have problems with memory, sleeping, incontinence, pain, uncontrolled body movement or who get out of bed and walk unsafely without assistance. For at-risk patients, use only with proper bed side rail protective barriers. There is also an increased risk of entrapment when bed rails are used in conjunction with a low air loss product.
    WARNING: Bed side rails are not restraining devices. If restraint is required, use only
    proper protective restraints. Follow the manufacturer’s instructions and applicable regulations. Monitor patient frequently.
    WARNING: DO NOT push or pull the bed by the bed rails. WARNING: GF Health Products, Inc. assumes no responsibility for any damage or injury
    caused by improper installation of bed rails or unauthorized bed rail use. Only Lumex bed rails are recommended for use with Patriot beds. Please consult the instructions that accompany your Lumex bed rails for complete rail assembly and installation instructions.

US0208-INS-LAB-RevF23

www.grahamfield.com

18

PATRIOT LIBERTY BED RAIL DESIGN
Lumex Patriot Liberty Bed Rails, designed specifically for use with Lumex Patriot Beds, were developed using the FDA Hospital Bed System Dimensional Guidance to Reduce Entrapment and tested to the Hospital Bed Safety Workgroup and FDA Dimensional Test Methods for Bed System Zones 1-4 and International Standard IEC60601-2-38 Requirements for the Safety of Electrically Operated Hospital Beds. For installation of these FDA-compliant bed rails, follow the installation
instructions that accompany them. Patriot Liberty Bed Rail descriptions follow.

GF6580BH-1: Quarter Rail

GF6580BH-1 Quarter Rail

head end slot
pivot point slot
pivot point

head end

foot end

slotted head deck angle
head end slots

foot end pivot point foot end pivot point slot
foot end slot

head end

foot deck angle foot end
foot end slots

The Quarter Rail, shown above, is approximately 18 inches in length when mounted on the Patriot bed. It can be used as a head assist, head rail, or foot rail.
Mounting slot locations utilized when the Quarter Rail is used as a head rail are shown in “head end slots” above (opposite slots are directly across bed).
Mounting slot locations utilized when the Quarter Rail is used as a foot rail are shown in “foot end slots” above (opposite slots are directly across bed).

US0208-INS-LAB-RevF23

www.grahamfield.com

19

GF6590BH-1: Half No-Gap Head Rail

head end slot pivot point slot pivot point

head end

GF6590BH-1 Half No-Gap Head Rail

foot end

slotted head deck angle
mounting slots

The Half No-Gap Head Rail, shown above, provides full head coverage of 31.5 inches and extends to eliminate the gap between the head board and the end of the rail. The GF6590BH-1 mounted on the bed’s head and the GF6580BH-1 mounted on the bed’s foot combine to create the Patriot split rail system.
Half No-Gap Head Rail mounting slot locations are shown in “mounting slots” above (opposite slots are directly across bed).

GF6570B-1: Full Length Rail

head end pivot point
foot end slot

head end slot head end

GF6570B-1 Full-Length Rail

foot end

mounting slots

The Full Length rail, shown above, is a nominal, telescoping full length rail that provides maximum length rail perimeter coverage.
Full Length Rail mounting slot locations are shown in “mounting slots” above (opposite side slots are directly across bed).

US0208-INS-LAB-RevF23

www.grahamfield.com

20

LUMEX UNIVERSAL BED RAILS If you install Lumex universal bed rails, follow the installation instructions that accompany them; the following instructions are provided to describe the differences between the installation of bed rail crossbraces on Patriot grid beds and spring beds.
WARNING: Do not use the bed rails as handles for getting into or out of bed; this could result in personal injury and damage to the bed rails.
GF6570A-1: Full Length Side Rail

HEADBOARD FOOTBOARD

GF6570A-1 Full-Length Side Rail

A
Spring Buttons
G1

A
G4

Position spring-loaded crossbraces #A into slots G1 and G4 on both sides of bed with spring buttons facing inward as shown above.

US0208-INS-LAB-RevF23

www.grahamfield.com

21

7 SERVICE PARTS, ALL MODELS
Service parts for all bed models are shown below and on the following two pages. See pictures and tables for appropriate service parts. BED COMPONENTS
HEAD
FOOT

Part number
690-7100-901 690-7105-902 690-7104-902 690-7001-000 690-7601-000 690-7004-000 690-7604-000

Description
Head section, includes hi/lo rod Foot section, semi-electric, includes motor Foot section, full-electric, includes motors End set, semi-electric, walnut panels End set, semi-electric, plastic panels End set, full-electric, walnut panels End set, full-electric, plastic panels

Semi-electric

US0208 X X

US0208PL X X

X X

Full-electric

US0458 US0458PL

X

X

X

X

X X

US0208-INS-LAB-RevF23

www.grahamfield.com

22

BED END COMPONENTS
6
FOOT

HEAD
5
1 8

2 3
7 4

Item Part number
1 690-7001-901 690-7601-901 690-7004-901 690-7604-901
2 690-7001-902 690-7601-902 690-7004-902 690-7604-902
3 999-0301-904 554-2001-221
4 100-4200-012 5 554-2001-015
690-5001-025
690-5004-015
690-5004-025
6 554-2001-059 690-5004-059
7 600-2001-912 600-2001-916 999-0353-000
8 600-2001-910
9 690-1000-100

Description
Head bed end, semi-electric, walnut panels Head bed end, semi-electric, plastic panels Head bed end, full-electric, walnut panels Head bed end, full- electric, plastic panels Foot bed end, semi-electric, walnut panels Foot bed end, semi-electric, plastic panels Foot bed end, full-electric, walnut panels Foot bed end, full-electric, plastic panels Caster, set of 4: 2 locking & 2 non-locking Caster, locking, each Caster socket, each End panel, head/foot, semi-electric, walnut panels End panel, head/foot, semi-electric, plastic panels End panel, head/foot, full-electric, walnut panels End panel, head/foot, full-electric, plastic panels Capping, bed end, head/foot, semi- electric Capping, bed end, head/foot, full-electric Foot elbow, full-electric Foot elbow with crank, semi-electric Foot crank only, semi-electric Elbow, head end, semi-electric & fullelectric End locking hardware, set of 4 (not shown)

Semi-electric

Full-electric

US0208 X
X
X X X X

US0208PL US0458 US0458PL

X X X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

US0208-INS-LAB-RevF23

www.grahamfield.com

23

BED SERVICE PARTS
FOOT

HEAD

1

4

2

3

Item Part number Description

Semi-electric, H7920SE

Full-electric, H7920FE

US0208 / US0208PL US0458 / US0458PL

1 690-2001-913 Motor and pendant hand control,

X

semi-electric

690-2001-411 Pendant hand control, semi-

X

electric

690-3001-943 Motor and pendant hand control,

X

full-electric

690-2001-414 Pendant hand control, full-electric

X

2 690-7001-944 Motor and bracket, hi/lo

X

690-3001-945 Motor, hi/lo, full-electric

X

3 554-2018-901 Hi/lo rod assembly

X

X

4 690-2001-412 Motor slide covers

X

X

5 690-1000-100 End locking hardware, set of 4 (not

X

X

shown)

Info: US0208 and US0208PL are identified on the foot section component label as

Patriot Semi-Electric Bed Model H7920SE.

Info: US0458 and US0458PL are identified on the foot section component label as

Patriot Full-Electric Bed Model H7920FE.

US0208-INS-LAB-RevF23

www.grahamfield.com

24

8 MAINTENANCE AND SAFETY CHECKS

Perform the following as needed or between patient placements, whichever happens sooner:

Electronics and Motors
Bed frames and sleeping surface
Cleaning Lubrication and mechanical

Check all controls to ensure that all functions work properly.

Foot control Head control

Hi/Lo (if applicable)

Check all cables for damaged or frayed wires.

Power cord Pendant hand control cord

Check to ensure that all plugs are fully inserted or attached.

Check to ensure that all wires are routed and attached properly so not to interfere with any moving parts.

Inspect motor casings for excessive wear and cracks.

Inspect motor slide caps for excessive wear and deformation.

Visually check all welds.

Head section

Foot section

Main Frame

Check joints between sleeping surface sections for loose fasteners.

Inspect frames and sleeping surface for bending and excessive wear.

The metal parts of the bed are covered with a powder coating. Clean all coated parts with mild detergent and warm water. Periodically raise head and foot sections of the bed and remove dust from frame. Also, periodically remove mattress and clean mattress deck.

Lubricate all caster roller and swivel bearings with light machine oil.

Check all bolts and tighten as needed.

WARNING: The bed’s electronic system contains no serviceable parts. Do not open the motors, cables, or pendant hand control. Only a Graham-Field authorized distributor or factory-trained personnel may perform service or adjustments on these components.

US0208-INS-LAB-RevF23

www.grahamfield.com

25

9 LIMITED WARRANTY

SCOPE OF WARRANTY

GF Health Products, Inc. (“GF”) warrants to the Original Purchaser only that it will replace or repair components, at GF’s sole discretion, that are defective in material or workmanship under normal use and service. All warranties are conditioned upon the proper use of the products strictly in accordance with good commercial practice and applicable GF instructions and manuals, including proper use and maintenance. To the extent that a third party warrants a component, GF conveys all of its rights under that warranty to the Original Purchaser, to the extent permitted. Original Purchaser is one who purchases this product new and unused from GF or a Certified GF Dealer/Distributor.

This limited warranty shall only apply to defects that are reported in accordance with the provisions set forth in this warranty
document, within the applicable warranty period and which, upon examination by GF or its authorized representative, prove to be a warranty item. (See Obtaining Warranty Service below) This limited warranty is not transferable. The warranted components and time periods are set forth below:
Lumex Patriot US0208 / US0208PL Semi-Electric Homecare Bed: . . . . 2 (two) years Lumex Patriot US0458 / US0458PL Full-Electric / Low Bed:. . . . . . . . . . . 2 (two) years

Labor is not included in the warranty.

The warranty period is as designated above. If a part is replaced under warranty, the original warranty period will not be

affected. All other replacement parts will be subject to the warranty period specified.

The applicable warranty period shall commence from date of shipment to the Original Purchaser, unless there is an expiration date on the component in which case the warranty shall expire on the earlier of warranty period or the expiration date.

OBTAINING WARRANTY SERVICE Contact the Dealer/Distributor from whom the product was purchased. If there is not a Dealer/Distributor, you must contact GF
directly by calling 770-368-4700, sending a fax request to 770-368-4932 or by e-mailing a request to cs@grahamfield.com. The Customer Service Representative will provide specific directions. Failure to abide by the specific directions will result in denial of the warranty claim. The warranty does not cover and GF shall not be liable for the following: 1) Defects, damage, or other conditions caused, in whole or in part, by misuse, abuse, negligence, alteration, accident, freight damage, tampering or failure to seek and obtain repair or replacement in a timely manner; 2) Products which are not installed, used, or properly cleaned and maintained as required in the official manual for the applicable product; 3) Products considered to be of a non-durable nature including, but not limited to: filters, fuses, gaskets, lubricants, and charts;
4) Accessories or parts not provided by GF;
5) Matching of color, grain or texture except to commercially acceptable standards; 6) Changes in color caused by natural or artificial light: 7) Charges by anyone for adjustments, repairs, replacement parts, installation or other work performed upon or in connection with
such products which are not expressly authorized in writing, in advance, by GF;
8) Any labor or shipping charges incurred in the replacement part installation or repair; 9) Costs and expenses of regular maintenance and cleaning; and
10) Representations and warranties made by any person or entity other than GF.
ENTIRE WARRANTY, EXCLUSIVE REMEDY AND CONSEQUENTIAL DAMAGES DISCLAIMER TO THE GREATEST EXTENT PERMITTED BY LAW, THIS WARRANTY IS GF’S ONLY WARRANTY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. EXCEPT IN CASES WHERE IMPLIED WARRANTIES MAY NOT BE VALIDLY WAIVED, GF MAKES NO IMPLIED WARRANTIES OF ANY KIND INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IF ANY MODEL OR SAMPLE WAS SHOWN TO THE CUSTOMER, SUCH MODEL OR SAMPLE WAS USED MERELY TO ILLUSTRATE THE GENERAL TYPE AND QUALITY OF THE PRODUCT AND NOT TO REPRESENT THAT THE PRODUCT WOULD NECESSARILY CONFORM TO THE MODEL OR SAMPLE IN ALL RESPECTS. THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF THE DEFECTIVE PARTS. GF SHALL NOT BE LIABLE FOR AND HEREBY DISCLAIMS ANY DIRECT, SPECIAL, INDIRECT, INCIDENTAL, EXEMPLARY OR CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO: DAMAGES FOR LOSS OF PROFITS OR INCOME, LOSS OF USE, DOWNTIME, COVER, OR EMPLOYEE OR INDEPENDENT CONTRACTOR WAGES, PAYMENTS AND BENEFITS. CERTAIN STATES AND COUNTRIES MAY CONFER ADDITIONAL RIGHTS REGARDING WARRANTIES AND IN THOSE INSTANCES, GF’S LIABILITY AND THE LIABILITY OF GF’S SUPPLIERS, SHALL BE LIMITED TO THE FULLEST EXTENT PERMITTED BY LAW.

The warranties contained herein, together with GF’s current Terms and Conditions, contain all the representations and warranties with respect to the subject matter of this document, and supersede all prior negotiations, agreements and understandings with respect thereto. The recipient of this document hereby acknowledges and represents that it has not relied on any representation, assertion, guarantee, warranty, collateral contract or other assurance, except those set out in this document.

For additional information on this product or this warranty, please contact a GF Customer Service Representative.

NOTES:

Additional terms and conditions may apply. See GF’s General Terms and Conditions on its website: www.grahamfield.com.

Freight claims must be notated on the appropriate shipping documents and must be made with immediacy. International,

federal and state regulations govern specific requirements for freight claims. Failure to abide by those regulations may

result in a denial of the freight claim. GF will assist you in filing the freight claim.

Claims for any short shipment must be made within three (3) days of the invoice date.

US0208-INS-LAB-RevF23

www.grahamfield.com

26

10 INDEX
A Assembly instructions 6 B Bed end assembly 9 Bed end locking hardware, install 10 Bed extension kit, 84″ 17 Bed height, low, full-electric 8 Bed height, standard, full-electric 8 Bed length adjustment 13 Bed operation 15 Bed rails 18 Bed rail safety 18 C Caster position (full-electric bed only) 8 CAUTION statement, significance 3,?4 Crank operation (semi-electric bed only) 16 D Deck height (high position) 17 Deck height (low position) 17 F Full- electric 13
G GF6570A-1 Full Length Side Rail 21 GF6570B-1 Full Length Rail 20 GF6580BH-1 Quarter Rail 19 GF6590BH-1 Half No-Gap Head Rail 20 H Head and foot assembly instructions 6 Hi/lo rod assembly 13 I Info statement, significance 3 Introduction 3 L Lumex universal bed rails 21 M Maintenance, bed frame and sleeping surface 25 Maintenance, cleaning 25 Maintenance, electronics 25 Maintenance, lubrication and mechanical 25 Maintenance and safety checks 25 Motor assembly 7 Motor assembly troubleshooting 8 Motor slide caps, install 8 Motor slide caps, remove 7

N NOTICE statement, significance 3 P Patriot Liberty bed rail design 19 Pendant hand control operation, full-electric 15 Pendant hand control operation, semi-electric 15 Power failure; battery operation 15 S Service parts, all models 22 Service parts, bed components 22 Service parts, bed end components 23 Specification, construction 17 Specification, weight 17 Specifications, dimensions 17 T Thermal motor protection 5 Trendelenburg position 16 Trendelenburg position, reverse 16 W WARNING statement, significance 3 Warranty 26 Weight capacity, maximum 3

US0208-INS-LAB-RevF23

www.grahamfield.com

27

Manufactured By: GF Health Products, Inc. One Graham-Feild Way,Atlanta GA 30340
© 2008, GF Health Products, Inc. All Rights Reserved. Lumex is a registered trademark of GF Health Products, Inc. US0208-INS-LAB-RevF23

+1 770.368.4700
Information contained herein is subject to change without notice. The most current and complete product information can be found on our website.
www.grahamfield.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals