Specifications:

  • Model: DSR-310BK
  • Type: Built-In Ozone Dish Sterilizer
  • Power Supply: 220V / 50Hz
  • Power Consumption: 310W
  • Weight: 26 kg
  • Dimensions: (H)595mm x (W)595mm x (D)500mm

Product Overview:

The DSR-310BK uses UV and ozone to sterilize tableware
effectively exterminating harmful bacteria. It then dries the
tableware using infrared rays, meeting two-star standards specified
in GB17988-2008.

Installation Guide:

1. Installation by Qualified Technicians:
Ensure installation is done by professionals to prevent electrical
hazards.

2. Socket Requirements: Use a socket with a
rated current loading of at least 10A and connect to a circuit with
an earth-leakage circuit breaker. Do not share the socket with
other appliances.

3. Grounding: Properly ground the socket to
avoid hazards. Do not connect the earth wire to water pipes, gas
pipes, lightning arresters, or telephone lines.

4. Weight Distribution: Avoid putting weight
pressure on the appliance after installation to prevent damage to
interior parts.

Installation Instructions:

  1. Follow the provided diagram to create space in a cabinet for
    embedding the sterilizer. Fix the sterilizer using four wood
    screws.

  2. The supporting base should have a loading capacity greater than
    60kg.

  3. Ensure the sterilizer sits securely on a flat surface. The
    drawer should move smoothly on the slide rail without juddering.
    Close the drawer completely for an airtight seal.

FAQ:

Q: What is the power supply requirement for the DSR-310BK?

A: The product operates on a power supply of 220V at 50Hz.

Q: What are the dimensions of the DSR-310BK?

A: The dimensions of the sterilizer are (H)595mm x (W)595mm x
(D)500mm.

Q: What type of sterilization methods does the DSR-310BK

use?

A: The DSR-310BK uses UV and ozone for effective sterilization
of tableware.

“`

DSR-310BK
Built-In Ozone Dish Sterilizer

Online Warranty Registration
Please read these instructions and warranty information carefully before use and keep them handy for future reference.
USER MANUAL
P.1

4

5

6

7

8

10

Please register your warranty information now!

11

For Warranty Terms & Conditions,

11

please refer to the last page of this user manual.

12

23

P.2

P.3

GB17988-2008

1

4

1

1

1. 2. 10A
3.
4.

P.4

P.5

  1. 2. 60kg

595

595 590

505 564

595

500

100-150

590

564
P.6

505

P.7

“”

P.8

90:005 60:0030:00 500:00 “”16

90:005 60:0030:00 500:00” “16

60:005 00:0045:0000:00 60:000000″”16

5 59060 30
45 9090
P.9

1. 2. 3. 4. 5. 6. 7. 8. 20 9. 10. 11. 12. 13. 14.

  1. 2. 15W253.
    7nm 3.

·

·

/ () (mg/m3) (L) kg kg mm mm

DSR-310BK 220 V / 50 Hz 310W 40 100 26 kg 6 8 75 (H)595mm X (W)595mm X (D)500mm (H) 590mm X (W) 564 X (D) 505mm

www.germanpool.com

P.10

P.11

Content

Product Summary

14

Installation Guide

15

Installation Instructions

16

L

Product Structure

17

N

S

Operating Instructions

18

220V~ 50Hz

Safety Precautions

20

Care and Maintenance

21

Technical Specifications

21

Circuit Diagram

22

Warranty Terms & Conditions

23

P.12

P.13

Product Summary

Product Overview
This product uses UV and ozone to first sterilize tableware (capable of effectively exterminating pyogenic coccus and pathogenic enterobecteriaceae), and then dry the tableware with infrared ray. Its sterilization result reaches two-star standard specified in GB17988-2008.

Area of Application
The sterilizer is applicable to household utensils.

Supplied Accessories (Packing List)

Dish sterilizer

Wood screw

1

4

User manual 1

Warranty card 1

Installation Guide
Read this manual carefully before using the appliance. Detailed illustration on its installation, operation, maintenance and precautions will be presented in this manual to help you fully utilize its functionalities.
1. The appliance should be installed by qualified technicians. Insufficient loading and improper installation would result in short circuit or other electrical hazards.
2. To ensure safety, the rated current loading of the socket should not be less than 10A; do not share the socket with other appliances; and the socket should be connected to circuit equipped with earth-leakage circuit breaker.
3. The socket should be properly grounded. To avoid hazards, the earth wire should not hook up with water pipes, gas pipes, lightning arresters and telephone lines.
4. Do not let the appliance sustain any weight pressure after installation; otherwise it could damage the interior parts.

P.14

P.15

Installation Instructions
1. Follow the diagram below to make room in a cabinet to smoothly embed the sterilizer. Open the drawer and use four wood screws to fix the sterilizer.
2. The mounting height of dish sterilizer is discretionary, but the loading capacity of the supporting base should be greater than 60kg.
3. The dish sterilizer should lie firmly on a flat surface. Make sure the drawer does not judder when it runs on the slide rail. Fully close the drawer to form an airtight enclosure.
Installation Diagram

Product Structure
Main Body
Control Panel Screw Hole Upper rack
Upper drawer Door grip
Lower drawer

595

595 590

564

505

595

500

Control panel

Display

Main body
Lower rack Slide rail

100-150

590

564
P.16

505

Smart Key

Disinfect Key

Heat Key

P.17

Operating Instructions

1. Open/close the door
Hold the door grip to horizontally pull out or push in the door. Do not apply brute force.

Watch the video clip

2. Tableware arrangement
Vertically place the clean and dry tableware on the dish rack. The spacing between the dishes should be sufficiently wide, otherwise the disinfection and heat drying result will be affected.

3. Auto power off protection
Upon opening the drawer, the sterilizer enters inactive mode and all functionalities will be suspended. Only by closing the drawer will resume operation.

4. Function Key

Display

Smart Key

Disinfect Key

Heat Key

System Initialization:
Make sure the appliance is properly installed in place. Close the drawer before connecting it to AC source. Plugging into the socket will emit a ticking sound, indicating the power is on and the machine enters standby mode.
P.18

Operating Instructions
Disinfection function:
On standby mode, press the “Disinfect” button. The corresponding indicator lights up and the timer reads 90:00. The disinfection duration can be set within 5 seconds. Press the button once again, the timer reads 60:00. Pressing 3 times the timer reads 30:00. The display turns off upon the 4th press. After setting the timer, if no other instructions are given within 5 seconds, the sterilizer will start running. When the timer ends at 00:00, disinfection is complete and 16 ticking sounds will be emitted.
Heat-Dry function:
On standby mode, press the “Heat” button. The corresponding indicator lights up and the timer reads 90:00. The heat-dry duration can be set within 5 seconds. Press the button once again, the timer reads 60:00. Pressing 3 times the timer reads 30:00. The display turns off upon the 4th press. After setting the timer, if no other instructions are given within 5 seconds, the sterilizer will start running. When the timer ends at 00:00, heat-drying is complete and 16 ticking sounds will be emitted.
Smart mode:
On standby mode, press the “Smart” button. The corresponding indicator lights up and the timer reads 60:00. If no other instructions are given within 5 seconds, the sterilizer will enter the Auto mode. When the timer ends at 00:00, the disinfection is complete. After a short while, the device will enter the standby mode with the timer starting to count from 45:00 to 00:00. Then the heat-dry function will be activated with the timer starting to count down from 60:00. When the timer ends at 00:00, heat-drying is complete and 16 ticking sounds will be emitted.
Integrated functions:
On standby mode, press the “Disinfect” button to set the timer. Then quickly press the “Heat” button within 5 seconds to integrate the disinfection and heat-dry function. Reversing the sequence of pressing the 2 buttons will yield the same result. The timer can be set at either 90, 60 or 30 minutes.
When the sterilizer runs on the integrated mode, the disinfection function will precede the heat-dry function. When disinfection is complete, the sterilizer will enter standby mode for 45 minutes before proceeding to heat- dry operation. Disinfection and heat-drying cannot run simultaneously. The “disinfect” indicator and “heat” indicator cannot light up simultaneously as well. To attain optimal performance, a combination of 90-minute disinfection and 90-minute heat-drying is recommended.
P.19

Safety Precautions
1. Hold the plug to unplug the sterilizer. Do not pull the cord to unplug the device. 2. If the power cord is damaged or other malfunctions occur, the appliance must be replaced or
repaired by the manufacturer or qualified technicians. 3. Make sure the supply voltage is consistent with the rated voltage of the machine. Otherwise,
damage to the appliance may result. 4. Except for qualified technicians, do not attempt to disassemble or repair the appliance. 5. Do not spray water onto the appliance, otherwise short circuit or electric shock may result. 6. Do not put lacquerware, thermally unstable plastic utensils or non-tableware (such as towels and
shoes) into the dish sterilizer. 7. Water remained on the tableware should be discarded before putting it into the sterilizer. 8. To avoid scald or the leakage of ozone, the drawer should remain close for 20 minutes after
disinfection (heat drying) completes. 9. To avoid scald, the appliance will automatically enter inactive mode when the drawer door is open.
It is not a sign of malfunction. 10. When disinfection begins, the door will be locked. Do not tug the door. 11. Make sure the earth wire of the power socket is securely grounded. 12. Do not let children or physically unfit person operate the dish sterilizer, otherwise scald, electric
shock or other accidents may result. 13. Do not plug or unplug the unit with a wet hand. 14. Do not place small objects outside the utensil basket to prevent them from dropping onto the
lower rack.
Warnings!
1. If leakage of ozone is detected or the light from germicidal tube can be seen through opaque objects at any angle during operation, stop using the appliance immediately and contact qualified technicians for repair.
2. If the germicidal tube is damaged, contact Repairs and Customer Service Center to replace it with a new one having 15W power and a wavelength of 253.7nm.
3. The disinfection and heat-dry function can only be performed when the door is close. Otherwise, leakage of ozone and UV radiation, or scald may result.
P.20

Care and Maintenance

Clean and maintain the sterilizer regularly according to the frequency of usage and conditions of the surrounding environment so that optimal disinfection and heat drying performance can be maintained and a longer service life can be achieved.

Watch the video clip

· Turn off and unplug the appliance and allow it to cool down before cleaning
and maintenance.
· Wear gloves while performing cleaning and maintenance to avoid potential injuries.
1. Use a soft cloth dipped in neutral detergent to remove dirt on the door, dish rack and inner tank. Wipe clean the residual detergent with another wet cloth and finally rub them with a dry cloth.
2. Regularly remove stagnant water accumulated at the bottom of the inner tank to avoid water overflow.
3. Never clean the exterior with petrol, alcohol, cleaning powder or other solvents. Otherwise it can discolour the main body or damage the surface coating.

Technical Specifications

Model Rated voltage/Frequency Power (Max) Ozone concentration (mg/m3) Capacity (L) Net weight (kg) Loading capacity (kg) Heat-drying temperature () Main Body Dimensions (mm) Installation Dimensions (mm)

DSR-310BK 220 V / 50 Hz 310W 40 100 26 kg Upper:6 Lower:8 75 (H)595mm X (W)595mm X (D)500mm (H) 590mm X (W) 564 X (D) 505mm

Specifications are subject to change without prior notice. If there is any inconsistency or ambiguity between the English version and the Chinese version, the Chinese version shall prevail. Refer to www.germanpool.com for the most up-to-date version of the Operating Instructions.

P.21

Circuit Diagram

Thermal Protector

Infraturebde ray

Electromagnetic Electromagnetic

lock

lock

UV tube
S
Starter

E lBeacltlraosnti c

Circuit Board

Gate controlled switch

Control Panel

L brown N blue
220V~ 50Hz

P.22

()

Warranty Terms & Conditions
Under normal operations, the product will gurantee a 1-year full warranty provided by German Pool (effective from the date of purchase).

  1. www.germanpool.com/ warranty
  • This warranty is not valid until customer registration information is received by our Service Centre within 10 days of purchase via one of the following means:
  1. Visit our website and register online: www.germanpool.com/ warranty
  2. Complete all the fields on the attached Warranty Card and mail it back to our Customer Service Centre.

Please fill out the form below. This information and the original purchase invoice will be required for any repairs. Warranty will be invalidated if information provided is found to be inaccurate.

Model No. : DSR-310BK

Serial No. :

Invoice No. :

Purchased From :

Purchase Date :

  1. 2. – – () –
    3. – – – –

1-3

145

10

3

+852 2333 6249

+853 2875 2699

+852 2356 9798

+853 2875 2661

repairs@germanpool.com

1. Customer who fails to present original purchase invoice will not be eligible for free warranty service.
2. Customer should always follow the operating instructions. This warranty does not apply to: – labour costs for on-site installation, check-up, repair, replacement of parts and other transportation costs; – damages caused by accidents of any kind (including material transfer and others); – operating failures resulting from applying incorrect voltage, improper usage, and unauthorized installations or repairs.
3. This warranty is invalid if: – the purchase invoice is modified by an unauthorized party; – the product is used for any commercial or industrial purposes; – the product is repaired or modified by unauthorized personnel, or unauthorized parts are installed; – the serial number is modified, damaged or removed from the product.
4. German Pool will, at its discretion, repair or replace any defective part.
5. This warranty will be void if there is any transfer of ownership from the original purchaser.

Customer Service & Repair Centre

Hong Kong, China

Macau, China

10/F, Kowloon Godown 1-3 Kai Hing Road, Kowloon Bay, Kowloon, Hong Kong Tel : +852 2333 6249 Fax : +852 2356 9798 Email : repairs@germanpool.com

3/F, Edificio Industrial Pou Fung, 145 Rua de Francisco Xavier Pereira, Macau Tel : +853 2875 2699 Fax : +853 2875 2661

This warranty is valid only in Hong Kong and Macau P.23

( ) German Pool (Hong Kong) Limited

Hong Kong, China 116 2113
Room 113, Newport Centre Phase II, 116 Ma Tau Kok Road, Tokwawan, Kowloon, Hong Kong. Tel: +852 2773 2888 Fax: +852 2765 8215

Mainland China 8
8th, Xinxiang Road, Wusha Industrial Park, Daliang, Shunde, Foshan, Guangdong, China Tel: +86 757 2980 8308 Fax: +86 757 2980 8318

Macau, China 145 3
3/F, Edificio Industrial Pou Fung, 145 Rua de Francisco Xavier Pereira, Macau Tel: +853 2875 2699 Fax: +853 2875 2661

HONG KONG TOP BRAND TEN YEAR ACHIEVEMENT AWARD
© © All rights reserved. Copying, reproducing or using the contents of this manual is not allowed without prior authorization from German Pool, violators will be prosecuted.

P.24

DSR-310BK-M-20(3.1)

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

GERMAN POOL User Manuals

Related Manuals