**** Please read this operating manual carefully before starting the device. Keep it in a safe place for future reference.
**** SAFETY INSTRUCTIONS
WARNING!
- Do not operate the appliance if it is visibly damaged.
- Do not block the gaps of the cool box with things like pin, wire, etc.
- Do not expose the appliance to rain or soak it in water.
- Do not place the appliance near naked flames or other heat sources (heaters, direct sunlight, gas ovens etc.)
- Do not store any explosive substances like spray cans with a flammable propellant.
- Ensure the supply cord is dry and not trapped or damaged. Do not locate multiple portable socket-outlets or portable power supplies at the rear of the appliance.
- Check the voltage specification on the type plate corresponds to that of the energy supply. The appliance is only to be used with the power supply unit provided with the appliance.
- Do not use electrical appliances inside the food storage compartments of the appliance, unless they are of the type recommended by the manufacturer.
- Once unpacked and before turning on, the appliance must be placed on a level surface for more than 6 hours.
- Make sure that the appliance stays horizontally when it is running. The tilt angle must be less than 5° for long time running and be less than 45° for short time running.
- Keep the ventilation openings in the unit casing or in the built-in structure free of obstacles. (Around the compressor ≥ 100mm).
- Keep the appliance stable on the ground or in the car; Do not drain upside down.
CAUTION!
- Repairs may only be carried out by qualified personnel. Incorrect repair may cause danger. The lamp and supply cord must be replaced by the manufacturer or qualified persons.
- Children aged 3-8 years are only allowed to load and unload refrigerating appliances.
- Children shall not play with the appliance.
- Cleaning and user maintenance shall not be made by children without supervision.
- The appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the device in a safe way and understand the hazards.
NOTICE!
- Disconnect the power supply before each cleaning and maintenance and after every use.
- Do not use sharp tools to defrost; Do not damage the refrigerant circuit.
- Check if the cooling capacity of the appliance is suitable for storing the food or medicine.
- Food may only be stored in its original packaging or in suitable containers.
- If the appliance is left empty for long periods, switch off, defrost, clean, dry, and leave the lid open to prevent mould developing within the appliance.
- The cool box contains a flammable gas inside the compressor.
- The appliance is designed for recreational camping.
IF YOU WISH TO FINALLY DISPOSE OF THE DEVICE
- Remove cables, lid, tie-down brackets from body with compressor and dispose according to local regulations. Ask your local recycling centre for details about how to do this in accordance with the applicable disposal regulations.
- Place the packaging material in the appropriate recycling waste bins wherever possible.
PRODUCT FEATURES
- High-efficiency DC compressor and conversion module.
- CFC free and great heat insulation.
- Lowest cooling to -20°C/-4°F (based on 25°C/77°F room temperature).
- Intelligent battery protection system prevents your vehicle from running out of battery.
- LED display control panel for temperature setting, USB charging port: SV/lA.
- Detachable lithium battery: 15600mAh/11.1V.
- Specific parts: interior drain plug, oversized wheels, telescopic handle, cupholders (in the lid), interior LED light, cutting board and bottle opener.
PRODUCT STRUCTURE
Note: There are buttons on both sides of the telescopic handle, press them at the same time to pull the rod. The cutting board can be moved by turning the knob on the top cover. Clean and dry the cutting board after every use.
REVERSE LID OPENING DIRECTION
The lid opening direction can be changed according to actual needs, please
follow the instructions below:
LID DISASSEMBLY:
LID INSTALLATION:
FUNCTIONS AND OPERATION
-
Note: the right compartment is on the side where the compressor is.
-
Power supply: Connect to DC 12V/24V or AC 100~240V (using dedicated adapter)
-
Display Screen Initialization: When the cool box is switched on the buzzer will make a long beep, and the display will be on for two seconds then enter the standby mode.
-
Power On/Off: Press to switch ON, long press for three seconds to switch OFF.
-
Temperature Setting: Under the running state, long press and at the same time for three seconds to switch ON/OFF the left compartment, long press and at the same time for three seconds to switch ON/OFF the right compartment. Two compartments cannot be switched off at the same time. When both left and right compartments are set in running state, press or to enter left compartment temperature setting, press to increase temperature, press to decrease temperature, and press to switch between left or right compartment. The setting will be saved after stop operating for four seconds
(Note: the temperature displayed is the current temperature of the compartments, it will take a while to reach the set temperature.)
Temperature setting range: -20~20°C (-4~68°F) -
Cooling Mode: Under the running state, press to switch to MAX (fast cooling) and ECO (Energy saving Mode). (Factory setting is MAX.)
• Battery Protection Mode: under the running state, long press for three seconds until screen flashes, then press again to select protection mode H (High), M (Medium) and L (Low).
(Factory setting is H).
-
VOLTAGE REFERENCE:
INPUT
MODE| DC 12V| DC 24V
---|---|---
CUT-OFF| CUT-IN| CUT-OFF| CUT-IN
L| 8.5V| 10.9V| 21.3V| 22.7V
M| 10.1V| 11.4V| 223V| 23.7V
H| 11.1V| 12.4V| 24.3V| 25.7V
-
the voltage is a theoretical value, there may be a deviation in different scenarios.
-
H should be set when the product is connected to car power, and M or L should be set when it is connected to a portable battery or other back-up battery.
-
Temperature Unit Setting: switch off the cool box, long press for three seconds until E1 displays, then switch to E5 by pressing again. Under E5 mode, press or to select Celsius or Fahrenheit.
(*Factory setting is °C.) -
Reset: Switch off the cool box, long press for three seconds until E1 displays, under E1 mode, long press at the same time for three seconds to reset it.
-
RECOMMENDED TEMPERATURES FOR COMMON FOOD:
| | | | | |
---|---|---|---|---|---|---
Drinks| Fruits| Vegetable| Ready-to- eat food| Wine| Ice cream| Meat
5°C/41 °F| 5-8°C/41-46°F| 3-10°C/37-50°F| 4°C/39°F| 10°C/50°F| -10cC/1 z- °F|
-18`C/0T
BATTERY OPERATION
*(NOT INCLUDED)
** Battery ON/OFF: A long press on the power button will switch the battery
ON/OFF. When the battery is OFF, a short press on the power button will show
how much battery power is left.
Model: Arctic Frost Rechargeable Battery (590202) / FSAK-002
Capacity: 15600mAh/l 73Wh Rated Voltage: 11.1V
Charging Limited Voltage (DC): 12.6V Charging Limited
Current (DC): 3A
- Power Indicator (Green: charging; Blue: discharging)
- Battery Indicator (show current battery)
- Power Button
- DC Charging Port
Warning: do not disassemble the battery!
- Battery charging (for reference only):
Note: It is suggested to switch off the cool box when charging the
battery (the power supply may mainly power the compressor when the cool box is
running).
If connecting to a solar panel, please place the cool box in a cool place to
dissipate heat. The charging input power should be higher than the working
power of the cool box (about 40-45W), or switch off the refrigerator,
otherwise the battery will run out.
It is suggested to use 100W solar panel.
MAX Solar Input Voltage: SOV; MAX Solar Input Current: 1OA.
Note: the output of the solar panel is unstable, so it cannot power the
cool box directly. When using a solar panel, the battery should be put into
the cool box.
- Discharging time (for reference only): In the low battery protection mode, the battery can last about 4 hours after being fully charged. When the temperature of the cool box is set between 2~8°C (ambient temperature 25°C), it can last 12 hours after the internal temperature stabilizes. Remove or switch off the battery to prevent self-discharge when not in use.
CARE AND MAINTENANCE
Cleaning:
- Switch off and unplug the device first to avoid electric shock.
- Use a wet cloth to clean the device and then wipe with a dry cloth.
- Do not soak the cool box in water or clean it under running water.
- Do not use abrasive cleaning agents during cleaning as these can damage the device.
Storage:
If the device will not be in use for a long time, please follow these
instructions:
- Switch off and unplug the device.
- Take out all the items stored in the device.
- Wipe off excess water with a soft rag.
- Put the cool box in a cool and dry place.
- Leave the lid slightly open to prevent odors from forming.
- Recommended storage environment: Ambient temperature: 25°C, ambient humidity: ≤ 75%.
Defrosting:
- Humidity can form frost in the interior of the cooling device or on the evaporator. This reduces the cooling capacity. Defrost the device in good time to avoid this.
- Switch off and unplug the device first to avoid electric shock.
- Take out all the items stored in the device.
- Keep the lid open.
- Wipe off the defrosted water.
** Never use hard or pointed tools to remove ice or to free objects frozen
onto the device.
Replacing the AC plug fuse (220-240V)**
- Unplug the cable from the mains socket and the cool box charging port.
- Pry open the fuse cover with a small flat head screwdriver in the center of the cable plug. Replace fuse with a new one that has the same rating (BS 1362 13A).
- Re-assemble the cable plug in the reverse order.
Replacing the cool box fuse (15A)
- Unplug the cable from the mains or 12V socket and the cool box charging port.
- Pry open the fuse cover with a small flat head screwdriver in the cool box charging port. Replace fuse with a new one that has the same rating (ATO regular blade fuse 15A).
- Re-assemble the charging port in the reverse order.
TROUBLESHOOTING
Issues | Cause/Suggestions |
---|---|
Cool box does not work | • Check if the switch is on. |
• Check if the plug and socket are properly connected. Check if the fuse has
been burnt.
• Check if the power supply is malfunctioned.
• Switching the cool box on/off frequently may cause start delay of the
compressor.
Cool box compartments are too warm| • The lid is opened frequently
• A large amount of warm or hot food was stored recently.
• The cool box has been disconnected for a long time
Food is frozen| • The temperature was set too low
There is “water flow” noise from inside the cool box| • It is a normal
phenomenon, caused by the flow of refrigerant.
There are waterdrops around the cool box casing or lid gap| • It is a normal
phenomenon, the moisture will condense to water when it touches a cold surface
of the cool box.
The compressor is slightly noisy when starting| • It is a normal phenomenon,
the noise will be reduced after the compressor works stably.
Code Fl displayed| • Possible cause: low voltage to cool box. Adjust the
battery protection from High to Medium or from Medium to Low.
Code F2 displayed| • Possible cause: condenser fan is overloaded. Disconnect
power to cool box for 5 minutes and re-start. If the code shows again, contact
manufacturer for service.
Code F3 displayed| • Possible cause: the compressor starts too frequently.
Disconnect power to cool box for 5 minutes and re-start. If the code shows
again, contact manufacturer for service.
Code F4 displayed| • Possible cause: compressor not kicking in. Disconnect
power to cool box for 5 minutes and re-start. If the code shows again, contact
manufacturer for service.
Code F5 displayed| • Possible cause: overheating of the compressor and
electronics. Disconnect power to cool box for 5 minutes and re-start. If the
code shows again, contact manufacturer for service.
Code F6 displayed| • Possible cause: no parameter can be detected by the
controller. Disconnect power to cool box for 5 minutes and re-start. If the
code shows again, contact manufacturer for service.
Code F7 or F8 displayed| • Possible cause: temperature sensor is faulty.
Contact manufacturer for service.
*For models with FSAK-002 detachable battery, if code Fl displayed, unplug or turn off the battery, or connect to DC12/24V/AC100-240V (using the adapter) power supply to power the compressor and battery in time to avoid long-term micro-current draining the battery.
GUARANTEE
The statutory guarantee period applies.
If the product is defective, please contact the manufacturer (see the back of
the instruction manual) or your retailer.
We strive to have spare parts available for up to 10 years.
For more information please see www.outwell.com
For repair and guarantee processing, please include the following documents
when you send in the device:
- A copy of the receipt with purchasing date
- A reason for claim or description of the fault.
TECHNICAL INFORMATION
Model | Arctic Frost 35 590197 /TWW35 |
---|---|
Climatic Category | T, ST, N , SN |
Rated Voltage AC(Adaptor) | 100V – 240V 50-60Hz |
Rated Voltage DC | 12V/24V **** |
Rated Current for AC(Adaptor) | 1.2A – 0.5A |
Rated Current for DC | 5.0A(12V) / 2.5A(24V) |
Protective Classification
of Electric Shock Resistance|
Refrigerant| R134a(40g)
Foam Vesicant| C51-110
Inside volume| 38.8L
Model | Arctic Frost 45 590199 / TWW55 |
---|---|
Climatic Category | T, ST, N , SN |
Rated Voltage AC(Adaptor) | 100V – 240V 50-60Hz |
Rated Voltage DC | 12V/24V **** |
Rated Current for AC(Adaptor) | 1.2A – 0.5A |
Rated Current for DC | 5.0A(12V) / 2.5A(24V) |
Protective Classification
of Electric Shock Resistance|
Refrigerant| R134a(40g)
Foam Vesicant| C51-110
Inside volume| 38.8L
Model | Arctic Frost 45 590199 / TWW45 |
---|---|
Climatic Category | T, ST, N , SN |
Rated Voltage AC(Adaptor) | 100V – 240V 50-60Hz |
Rated Voltage DC | 12V/24V **** |
Rated Current for AC(Adaptor) | 1.2A – 0.5A |
Rated Current for DC | 5.0A(12V) / 2.5A(24V) |
Protective Classification
of Electric Shock Resistance|
Refrigerant| R134a(40g)
Foam Vesicant| C51-110
Inside volume| 38.8L
Oase Outdoors ApS
EU: Kornvej 9, DK-7323 Give, Denmark. UK: One Glass Wharf, Bristol, BS2 0ZX
outwell.com
Outwell® is a reg. trademark of Oase Outdoors
EU: Kornvej 9, DK-7323 Give, Denmark
UK: One Glass Wharf, Bristol, BS2 0ZX
© 11/2022 Oase Outdoors ApS. Made in China
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>