VISTA 1054WM Linear LED Floodlight Installation Guide

August 27, 2024
VISTA

VISTA 1054WM Linear LED Floodlight

Specifications

  • Model: 1054WM
  • Product Type: Commercial Series Linear Floodlight
  • Adjustability: Luminaire throw can be adjusted up to +/- 15 degrees from horizontal
  • Mounting Options: Direct mounting to structural surface over a recessed 4-0 box or weatherproof outlet box
  • Power Supply: Requires electrical supply connection
  • Dimming Compatibility: Supports 0-10V dimming

FAQs

  • Q: Can the luminaire be adjusted vertically?
    • A: Yes, the luminaire throw can be adjusted up to +/- 15 degrees from horizontal, allowing for vertical adjustment.
  • Q: What type of dimming is supported by the luminaire?
    • A: The luminaire supports 0-10V dimming. Connect Dimming Supply (+) to Dimming Load (Purple) & Dimming Supply (-) to Dimming Load (Grey).
  • Q: How do I secure the Wall Mount Plate to the box?
    • A: Use the provided mount screws to affix the Wall Mount Plate securely to either a recessed 4-0 Box or a Weatherproof Outlet Box.

PRODUCT INFORMATION

IMPORTANT NOTE:

  • Luminaire must be installed and grounded by the National Electrical Code (NEC) and local codes.
  • Luminaire is UL-listed for above-grade installation only.
  • Always use UL-recognized wire connectors for connections.
  • MAINTENANCE: To assure proper operation and efficiency, the lens must be kept clean and free of dirt, dust, leaves, trash, and mineral deposits from water. A regularly scheduled maintenance program is recommended.
  • SAFETY WARNING: Luminaire can become hot. Take care when locating luminaires.
  • NOTE : Save these instructions for future reference.

MOUNTING INSTRUCTIONS

DIRECT LUMINAIRE MOUNTING TO STRUCTURAL SURFACE OVER RECESSED 4-0 BOX (by others):

NOTE: The Luminaire can be mounted such that the direction of illumination will be up or down. The Luminaire throw can be adjusted up to +/- 15 degrees from horizontal.
NOTE: The Wall Mount Plate has four mounting holes, two of which will be unused when mounting over a recessed 4-0 BOX. Determine which holes will be unused and plug them by following the image and step 2 below.

  1. Make sure the electrical supply is off at the circuit breaker before starting luminaire installation or servicing the luminaire.
  2. Install two 8-32 Mount Screws (by Vista) through the Wall Mount Plate and 4-0 Gasket, in the two holes to be un-used, and affix with two Washers (by Vista) and 8-32 Hex Stand-Offs (by Vista). Firmly tighten by hand.
  3. Route luminaire Load conductors (by Vista) into recessed 4-0 Box (by others). Using NEC-approved wiring methods, attach Supply conductors (by others) to the luminaire Load conductors observing polarity: Supply (+) to Load (black), Supply (-) to Load (White), and Supply (Ground) to Load (Green). If 0-10V dimming is used connect the Dimming Supply (+) to the Dimming Load (Purple) & Dimming Supply (-) to Dimming Load (Grey).
  4. Affix the Wall Mount Plate to the 4-0 box using the remaining two 8-32 Mount Screws (by Vista). Tighten.
  5. Adjust the aim of the luminaire, up to +/- 15 degrees from horizontal, and firmly re-tighten the Aiming Adjustment Screw.
  6. Lock the desired aim of the luminaire by firmly tightening the two Set Screws on both sides of the Wall Mount Plate.
  7. Supply power to the luminaire and check for proper operation.

DIRECT LUMINAIRE MOUNTING TO STRUCTURAL SURFACE OVER WEATHERPROOF OUTLET BOX (by others):

NOTE: The Luminaire can be mounted to a standard 4” diameter Weatherproof Outlet Box with a 3 1/2” Bolt Circle Diameter (BCD) using four 10-24 Mounting Screws.
NOTE: The Luminaire can be mounted such that the direction of illumination will be up or down. The Luminaire throw can be adjusted up to +/- 15 degrees from horizontal.

  1. Make sure the electrical supply is off at the circuit breaker before starting luminaire installation or servicing the luminaire.
  2. Route luminaire Load conductors (by Vista) into Weatherproof Outlet boxes (by others). Using NEC-approved wiring methods, attach Supply conductors (by others) to the luminaire Load conductors observing polarity: Supply (+) to Load (black), Supply (-) to Load (White), and Supply (Ground) to Load (Green). If 0-10V dimming is used connect the Dimming Supply (+) to the Dimming Load (Purple) & Dimming Supply (-) to the Dimming Load (Grey).
  3. Affix the Wall Mount Plate to the Weatherproof Outlet Box (by others) using the four 10-24 Mount Screws (by Vista). Tighten.
  4. Adjust the aim of the luminaire, up to +/- 15 degrees from horizontal, and firmly re-tighten the Aiming Adjustment Screw.
  5. Lock the desired aim of the luminaire by firmly tightening the two Set Screws on both sides of the Wall Mount Plate.
  6. Supply power to the luminaire and check for proper operation.