VISTA 1054WM Linear LED Floodlight
Specifications
- Model: 1054WM
- Product Type: Commercial Series Linear Floodlight
- Adjustability: Luminaire throw can be adjusted up to +/- 15 degrees from horizontal
- Mounting Options: Direct mounting to structural surface over a recessed 4-0 box or weatherproof outlet box
- Power Supply: Requires electrical supply connection
- Dimming Compatibility: Supports 0-10V dimming
FAQs
- Q: Can the luminaire be adjusted vertically?
- A: Yes, the luminaire throw can be adjusted up to +/- 15 degrees from horizontal, allowing for vertical adjustment.
- Q: What type of dimming is supported by the luminaire?
- A: The luminaire supports 0-10V dimming. Connect Dimming Supply (+) to Dimming Load (Purple) & Dimming Supply (-) to Dimming Load (Grey).
- Q: How do I secure the Wall Mount Plate to the box?
- A: Use the provided mount screws to affix the Wall Mount Plate securely to either a recessed 4-0 Box or a Weatherproof Outlet Box.
PRODUCT INFORMATION
IMPORTANT NOTE:
- Luminaire must be installed and grounded by the National Electrical Code (NEC) and local codes.
- Luminaire is UL-listed for above-grade installation only.
- Always use UL-recognized wire connectors for connections.
- MAINTENANCE: To assure proper operation and efficiency, the lens must be kept clean and free of dirt, dust, leaves, trash, and mineral deposits from water. A regularly scheduled maintenance program is recommended.
- SAFETY WARNING: Luminaire can become hot. Take care when locating luminaires.
- NOTE : Save these instructions for future reference.
MOUNTING INSTRUCTIONS
DIRECT LUMINAIRE MOUNTING TO STRUCTURAL SURFACE OVER RECESSED 4-0 BOX (by others):
NOTE: The Luminaire can be mounted such that the direction of
illumination will be up or down. The Luminaire throw can be adjusted up to +/-
15 degrees from horizontal.
NOTE: The Wall Mount Plate has four mounting holes, two of which will be
unused when mounting over a recessed 4-0 BOX. Determine which holes will be
unused and plug them by following the image and step 2 below.
- Make sure the electrical supply is off at the circuit breaker before starting luminaire installation or servicing the luminaire.
- Install two 8-32 Mount Screws (by Vista) through the Wall Mount Plate and 4-0 Gasket, in the two holes to be un-used, and affix with two Washers (by Vista) and 8-32 Hex Stand-Offs (by Vista). Firmly tighten by hand.
- Route luminaire Load conductors (by Vista) into recessed 4-0 Box (by others). Using NEC-approved wiring methods, attach Supply conductors (by others) to the luminaire Load conductors observing polarity: Supply (+) to Load (black), Supply (-) to Load (White), and Supply (Ground) to Load (Green). If 0-10V dimming is used connect the Dimming Supply (+) to the Dimming Load (Purple) & Dimming Supply (-) to Dimming Load (Grey).
- Affix the Wall Mount Plate to the 4-0 box using the remaining two 8-32 Mount Screws (by Vista). Tighten.
- Adjust the aim of the luminaire, up to +/- 15 degrees from horizontal, and firmly re-tighten the Aiming Adjustment Screw.
- Lock the desired aim of the luminaire by firmly tightening the two Set Screws on both sides of the Wall Mount Plate.
- Supply power to the luminaire and check for proper operation.
DIRECT LUMINAIRE MOUNTING TO STRUCTURAL SURFACE OVER WEATHERPROOF OUTLET BOX (by others):
NOTE: The Luminaire can be mounted to a standard 4” diameter Weatherproof
Outlet Box with a 3 1/2” Bolt Circle Diameter (BCD) using four 10-24 Mounting
Screws.
NOTE: The Luminaire can be mounted such that the direction of
illumination will be up or down. The Luminaire throw can be adjusted up to +/-
15 degrees from horizontal.
- Make sure the electrical supply is off at the circuit breaker before starting luminaire installation or servicing the luminaire.
- Route luminaire Load conductors (by Vista) into Weatherproof Outlet boxes (by others). Using NEC-approved wiring methods, attach Supply conductors (by others) to the luminaire Load conductors observing polarity: Supply (+) to Load (black), Supply (-) to Load (White), and Supply (Ground) to Load (Green). If 0-10V dimming is used connect the Dimming Supply (+) to the Dimming Load (Purple) & Dimming Supply (-) to the Dimming Load (Grey).
- Affix the Wall Mount Plate to the Weatherproof Outlet Box (by others) using the four 10-24 Mount Screws (by Vista). Tighten.
- Adjust the aim of the luminaire, up to +/- 15 degrees from horizontal, and firmly re-tighten the Aiming Adjustment Screw.
- Lock the desired aim of the luminaire by firmly tightening the two Set Screws on both sides of the Wall Mount Plate.
- Supply power to the luminaire and check for proper operation.
CONTACT INFORMATION
- www.VistaPro.com
- email@vistapro.com
- Fax: (888) 670-VISTA (8478)
- 1625 Surveyor Avenue
- Simi Valley, CA 93063
- 805-527-0987
- (800) 766-VISTA (8478)
Vista Professional Outdoor Lighting reserves the right to modify the design and/or construction of fixtures shown in this document without further notification.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>