Step 1: Preparing for Installation
Ensure the electrical supply is switched off at the circuit breaker before proceeding with the installation or servicing of the luminaire.
Step 2: Mounting the Luminaire
- Thread the Luminaire Supply Conductor cable through the Cord Seal and the Yoke Mount Bushing into the Junction Box.
- Tighten the Yoke Mount Bushing securely.
Step 3: Connecting the Conductors
Route the luminaire supply conductors into a wet location rated J-Box and connect them to the conduit supply conductors observing polarity (line to black, neutral to white, ground to green).
Step 4: Securing the Junction Box
Secure the Junction Box Lid onto the Junction Box using the provided screws. Ensure they are tightened properly.
Step 5: Adjusting and Securing
Adjust the aim of the fixture as needed and re-tighten the Yoke Aiming Hex Nut(s) underneath the Yoke Decorative Caps.
Step 6: Final Steps
- Re-assemble the Decorative Caps onto the Yoke.
- Tighten the Yoke Locking Set Screws to secure the aiming.
- Supply power to the luminaire and check for proper operation.
Frequently Asked Questions
- Q: Can this luminaire be used in outdoor environments?
- A: Yes, this luminaire is suitable for wet locations with its IP65 rating.
- Q: How do I ensure proper wiring connections?
- A: Connect the supply and luminaire conductors following approved wiring methods and observing polarity (line to black, neutral to white, ground to green).
IMPORTANT NOTE:
- Luminaire must be installed and grounded in accordance with the National Electrical Code (NEC) and local codes.
- Luminaire is UL listed for above grade installation only.
- Always use UL recognized wire connectors for connections.
- MAINTENANCE: To assure proper operation and efficiency, lens must be kept clean and free of dirt, dust,leaves, trash and mineral deposits from water. A regular scheduled maintenance program is recommended.
- SAFETY WARNING: Luminaire can become hot. Take care when locating luminaires.
- NOTE: Save these instructions for future reference.
Installation Instruction
LUMINAIRE MOUNTING (YOKE) TO JUNCTION BOX(ES)
- Make sure electrical supply is off at circuit breaker before starting luminaire installation or servicing luminaire.
- Thread Luminaire Supply Conductor cable through the Cord Seal, the Yoke Mount Bushing through Yoke center hole and into Junction Box Ld. Tighten the Yoke Mount Bushing fully.
- Route luminaire supply conductors into wet location rated J-Box (by others). Attach conduit supply conductors (by others) to the luminaire conductors observing polarity, line to black, neutral to white, and ground to green. Connect the supply / luminaire conductors using approved wiring methods.
- Secure the Junction Box Lid onto the Junction Box using the Junction Box Lid Screws. Tighten.
- Adjust the aim of the fixture and firmly re-tighten the Yoke Aiming Hex Nut(s) underneath the Yoke Decorative Caps.
- Re-assemble the Decorative Caps onto the Yoke.
- Tighten the Yoke Locking Set Screws to secure the aiming.
- Supply power to the luminaire and check for proper operation.