VISTA 1051YM Linear LED Floodlight Instruction Manual

June 1, 2024
VISTA

VISTA 1051YM Linear LED Floodlight

VISTA-1051YM-Linear-LED-Floodlight-product

Specifications

  • Model Numbers: 1051YM, 1052YM, 1054YM
  • Series: Architectural Series
  • Power Supply: Electrical
  • Mounting Type: Yoke Mounting to Junction Box
  • Color: Black
  • Material: Aluminum
  • IP Rating: IP65 (Suitable for wet locations)

Product Usage Instructions

Step 1: Preparing for Installation

Ensure the electrical supply is switched off at the circuit breaker before proceeding with the installation or servicing of the luminaire.

Step 2: Mounting the Luminaire

  1. Thread the Luminaire Supply Conductor cable through the Cord Seal and the Yoke Mount Bushing into the Junction Box.
  2. Tighten the Yoke Mount Bushing securely.

Step 3: Connecting the Conductors

Route the luminaire supply conductors into a wet location rated J-Box and connect them to the conduit supply conductors observing polarity (line to black, neutral to white, ground to green).

Step 4: Securing the Junction Box

Secure the Junction Box Lid onto the Junction Box using the provided screws. Ensure they are tightened properly.

Step 5: Adjusting and Securing

Adjust the aim of the fixture as needed and re-tighten the Yoke Aiming Hex Nut(s) underneath the Yoke Decorative Caps.

Step 6: Final Steps

  1. Re-assemble the Decorative Caps onto the Yoke.
  2. Tighten the Yoke Locking Set Screws to secure the aiming.
  3. Supply power to the luminaire and check for proper operation.

Frequently Asked Questions

  • Q: Can this luminaire be used in outdoor environments?
    • A: Yes, this luminaire is suitable for wet locations with its IP65 rating.
  • Q: How do I ensure proper wiring connections?
    • A: Connect the supply and luminaire conductors following approved wiring methods and observing polarity (line to black, neutral to white, ground to green).

IMPORTANT NOTE:

  • Luminaire must be installed and grounded in accordance with the National Electrical Code (NEC) and local codes.
  • Luminaire is UL listed for above grade installation only.
  • Always use UL recognized wire connectors for connections.
  • MAINTENANCE: To assure proper operation and efficiency, lens must be kept clean and free of dirt, dust,leaves, trash and mineral deposits from water. A regular scheduled maintenance program is recommended.
  • SAFETY WARNING: Luminaire can become hot. Take care when locating luminaires.
  • NOTE: Save these instructions for future reference.

Installation Instruction

LUMINAIRE MOUNTING (YOKE) TO JUNCTION BOX(ES)

  1. Make sure electrical supply is off at circuit breaker before starting luminaire installation or servicing luminaire.
  2. Thread Luminaire Supply Conductor cable through the Cord Seal, the Yoke Mount Bushing through Yoke center hole and into Junction Box Ld. Tighten the Yoke Mount Bushing fully.
  3. Route luminaire supply conductors into wet location rated J-Box (by others). Attach conduit supply conductors (by others) to the luminaire conductors observing polarity, line to black, neutral to white, and ground to green. Connect the supply / luminaire conductors using approved wiring methods.
  4. Secure the Junction Box Lid onto the Junction Box using the Junction Box Lid Screws. Tighten.
  5. Adjust the aim of the fixture and firmly re-tighten the Yoke Aiming Hex Nut(s) underneath the Yoke Decorative Caps.
  6. Re-assemble the Decorative Caps onto the Yoke.
  7. Tighten the Yoke Locking Set Screws to secure the aiming.
  8. Supply power to the luminaire and check for proper operation.

Product Overview

VISTA-1051YM-Linear-LED-Floodlight-fig-1

Contact

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

VISTA User Manuals

Related Manuals