Metropolitan Product Name Prima Vista 4-Light Aged Antique Bra N7353-790 4-Light Aged Antique Brass Semi-Flush Mount Instruction Manual

October 30, 2023
Metropolitan Product Name Prima Vista 4-Light Aged Antique Bra

INSTALLATION INSTRUCTIONS
Item#N7353-790 (New. 10/14/2021) 

N7353-790 4-Light Aged Antique Brass Semi-Flush Mount

WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER.

|
---|---

PREPARATION

(Fig. 1 & Fig. 4)

  1. Shut off power at the fuse box or circuit breaker box and remove the old fixture including the mounting hardware.
  2. Carefully unpack your new fixture and lay out all the parts in a clean area. Take care not to misplace any small parts necessary for installation.
  3. The arms have been placed to lay flat for shipping. Adjust arms to proper position. (See Fig. 4)

ASSEMBLING THE FIXTURE

(Fig. 1 & Fig. 2)

  1. Thread stem (G) onto all thread (H) of socket assembly (L).
  2. Thread swivel (E) of upper assembly onto stem (G).
  3. Carefully place bolts (F) through holes on top of frame assembly (J). Then tighten with plastic washer and finial (K).
  4. Place mounting plate (A) to junction box (Not included) using mounting screws (B) (Size: #8-32N*L1”). The side of mounting plate marked “GND” must face out.
  5. The support cable is provided to support weight of fixture while wiring. Align fixture to mounting plate (A) and attach hook (M) on end of support cable (N) into a slot located on mounting plate (A).
    Carefully allow support cable (N) to support weight of fixture while wiring.

CONNECTING THE WIRES

(Fig. 3)

  1. Connect the electrical wires as shown in Fig. 3, making sure that all wire connectors are secured. If your junction box has a ground wire (green or bare copper), connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the mounting plate (A) using the green screw provided.
  2. Tuck wire connections neatly into junction box.

COMPLETING THE INSTALLATION

(Fig. 1)

  1. Place canopy (C) to mounting plate (A) and secure with screws (D).
  2. Install (4) four candelabra base bulbs (I) up to 60 watts each or CFL or LED equivalent (not included) in accordance with the fixture specification.
    —DO NOT EXCEED THE MAXIMUM WATTAGE RATING!

Your installation is now complete. Return power to the junction box and test the fixture.
Note: Illustration (Fig. 1) on this manual is for installation purposes only. It may or may not be identical to the fixture purchased.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals