TONOR TW720 UHF Wireless Microphone Instruction Manual
- August 26, 2024
- TONOR
Table of Contents
- Thank you
- Package Including
- OPERATING ENVIRONMENTS & NOTES
- SPECIFICATIONS
- MICROPHONE OPERATION INSTRUCTION
- TROUBLESHOOTING
- EU Declaration of conformity
- Conditions and restrictions for using frequencies
- WARRANTY
- FCC Statement
- ISED Statement
- FCC Radiation Exposure Statement
- Operating Frequency
- CUSTOMER SUPPORT
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TONOR TW720 UHF Wireless Microphone
Thank you
Thank you for purchasing TONOR wireless microphone. This manual is intended to help you understand all about this microphone and how to use it. TONOR always strives for the ultimate user experience. All our knowledge and passion for audio technology are incorporated into building microphones with high performance for you. The TONOR microphone is high quality and easy to use to achieve the best user experience.
Enjoy your microphone!
TONOR Team
Package Including
OPERATING ENVIRONMENTS & NOTES
- When using this device, keep it away from water.
- Use the device in ventilated environment, keep it away from fire.
- Since it’s a wireless device, please keep it away from other interfering sources.
- Don’t take apart the device.
- Please use the standard power supply, high voltage may damage the device.
- When the battery is low, the mic or receiver will automatically shut down. Please charge it.
- Recommended to use the original charging cable for all charging equipment. Or use a Type-A to Type-C charging cable.
- Not recommended to use equipment while charging.
SPECIFICATIONS
- Frequency Range: 540-570MHz
- Channels: 25ch/each channel
- RF Power : 10dBm
- Frequency Response: 50Hz-18kHz
- T.H.D : ≤0.5%
- Mic Battery: Lithium battery 3.7V/1200mAh
- Mic Charging Time : 2-3 hours
- Mic Battery Life: 7-9 hours
- Receiver Battery: Lithium battery 3.7V/1500mAh
- Receiver Charging Time ; 2-3 hours
- Receiver Battery Life : 7-9 hours
- Working Distance: Up to 100m
MICROPHONE OPERATION INSTRUCTION
- LCD Display
- Power Button with LED Indicator
- Click to turn on. Long press for 2 seconds to turn off.
- Click to be mute when it is power on. And the LED light is red.
- LED Indicator
- Power on state: Blue light means power on. Light off means mute.
- Power off state: Red light means charging and light off when completed.
- Power on state: Purple light means charging and red light means mute.
- TYPE-C Charging Interface
- VOL:
- Click to adjust the volume in U01 to U05 cycle.
- Press and hold for 4 seconds to lock the microphones and the current receiver. At this time, the screen displays “—-” to indicate successful locking. When using multiple sets, each set needs to be operated once.
- SET
- Click to adjust the frequency in CH01 to CH25 cycle.
- Press and hold for 5 seconds to switch between MIC1/MIC2. Please ensure that the two microphones are MIC1 and MIC2 for normal use.
TROUBLESHOOTING
Turn on all the microphones, but one of them has on sound.
Confirm that the two microphones are MIC1 and MIC2 respectively. If not,
please press and hold the SET button for about 5 seconds to switch MIC1 and
MIC2. Then wait for the microphone and receiver to connect automatically.
Received signal with noise or interference
Change to other frequencies.
Check whether the receiving distance exceeds the maximum range.
Microphone or receiver cannot be turned on
Check whether microphone or receiver is full charged.
How to use multiple sets together
a. Make sure all devices are turned off.
b. Turn on the first set of receiver and microphone.
c. Then press and hold the VOL button of MIC1 and MIC2 for 4 seconds to
lock the microphones and receiver. The microphone screen displays “—-” to
indicate successful locking.
d. Turn off the first set of microphones and receiver.
e. Open the second set and repeat step 1 to step 4, and so on.
f. After all set are locked, turn on multiple sets at the same time.
Then click the SET button to set the unique frequency of each microphone.
EU Declaration of conformity
- RoHS Directive (2011/65/EU)
Hereby, Fujian EastWest Lifewit Technology Co.,LTD declares that the radio equipment type TW720 is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address:
https://www.tonormic.com/pages/eu-declaration-of-conformity
Conditions and restrictions for using frequencies
Conditions and restrictions for using frequencies There may be special
conditions and restrictions for using frequencies in your country.
Before putting the product into operation, find the information for your
country at the following address:
https://www.tonormic.com/pages/permitted-frequency-bands
WARRANTY
TONOR provides 2 years of after-sales service, free replacement to products that are NOT damaged resulting from accident, alteration, misuse, negligence, or abuse. If exceeding 30 days of Amazon return policy, you can still contact us through our Shopify TONORMIC. We will serve you with full sincerity!
FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
ISED Statement
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to\ provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement
The device has been evaluated to meet general RF exposure requirement. The
device can be used in portable exposure condition without restriction.
ISED Radiation Exposure Statement
The device has been evaluated to meet general RF exposure requirement. The
device can be used installed and operated with minimum distance 0mm between
the radiator and your body.
This device operates on a no-interference, no-protection basis. Should the user seek to obtain protection from other radio services operating in the same TV bands, a radio licence is required. For further details, consult Innovation, Science and Economic Development Canada’s Client Procedures Circular CPC-2-1-28, Voluntary Licensing of Licence-Exempt Wireless Microphones in the TV Bands.
Operating Frequency
MIC1 Frequencies
CH 01| 558 .9
CH 02| 559 .2
CH 03| 559 .6
CH 04| 559 .9
CH 05| 560 .3
CH 06| 560 .6
CH 07| 561
CH 08| 561 .3
CH 09| 561 .7
CH 10| 562
CH 11| 562 .4
CH 12| 562 .7
CH 13| 563 .1
CH 14| 563 .4
CH 15| 563 .8
CH 16| 564 .1
CH 17| 564 .5
CH 18| 564 .8
CH 19| 565 .2
CH 20| 565 .5
CH 21| 565 .9
CH 22| 566 .2
CH 23| 566 .6
CH 24| 566 .9
CH 25| 567 .3
MIC2 Frequencies
CH 01| 546 .3
CH 02| 546 .7
CH 03| 547
CH 04| 547 .4
CH 05| 547 .7
CH 06| 548 .1
CH 07| 548 .4
CH 08| 548 .8
CH 09| 549 .1
CH 10| 549 .5
CH 11| 549 .8
CH 12| 550 .2
CH 13| 550 .5
CH 14| 550 .9
CH 15| 551 .2
CH 16| 551 .6
CH 17| 551 .9
CH 18| 552 .3
CH 19| 552 .6
CH 20| 553
CH 21| 553 .3
CH 22| 553 .7
CH 23| 554
CH 24| 554 .4
CH 25| 554 .7
__
| AT| BE| BG| CY| CZ| DE
---|---|---|---|---|---|---
DK| EE| EL| ES| FI| FR
HR| HU| IE| IT| LT| LU
LV| MT| NL| PL| PT| RO
SE| SI| SK| UK(NI)| |
CUSTOMER SUPPORT
https://www.tonormic.com
support@tonormic.com
FUJIAN EASTWEST LIFEWIT TECHNOLOGY CO.,LTD | RM
1201-1205, BLD 18, 2ND PHASE OF INNOVATION PARK, FUZHOU 350108, CHINA
EASTWEST ELECTRONIC COMMERCE CO US LIMITED | 3500
SOUTH DUPONT HIGHWAY, SUITE G106 DOVER, DE 19901 UNITED
STATES LIFEWIT LIMITED | UNIT 2, VINCENT HOUSE, FIRCROFT WAY, EDENBRIDGE
UNITED KINGDOM
Lifewit GmbH | Friedenstraße 5 97072 Wuerzburg Germany
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>