TONOR TW790 Wireless Microphone Instruction Manual
- August 26, 2024
- TONOR
Table of Contents
- Thank you
- Package Including
- OPERATING ENVIRONMENTS & NOTES
- SPECIFICATIONS
- MICROPHONE OPERATION INSTRUCTION
- STEPS TO PAIR
- TROUBLESHOOTING
- EU Declaration of conformity
- Conditions and restrictions for using frequencies
- WARRANTY
- FCC Statement
- ISED Statement
- Operating Frequency
- Customer Support
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TONOR TW790 Wireless Microphone
Thank you
Thank you for purchasing TONOR wireless microphone. This manual is intended to
help you understand all about this microphone and how to use it. TONOR always
strives for the ultimate user experience. All our knowledge and passion for
audio technology are incorporated into building microphones with high
performance for you. The TONOR microphone is high quality and easy to use to
achieve the best user experience.
Enjoy your microphone!
Package Including
OPERATING ENVIRONMENTS & NOTES
- When using this device, keep it away from water.
- Use the device in ventilated environment, keep it away from fire.
- Since it’s a wireless device, please keep it away from other interfering sources.
- Don’t take apart the device.
- Please use the standard power supply, high voltage may damage the device.
- When the battery is low, the mic or receiver will automatically shut down. Please charge it.
- Recommended to use the original charging cable for all charging equipment. Or use a Type-A to Type-C charging cable.
- Not recommended to use equipment while charging.
SPECIFICATIONS
- Frequency range: 538.1-597.8MHz
- Channels: 100ch/each channel
- RF power: 10 dBm
- Frequency response: 40Hz-18kHz
- T.H.D: ≤0.5%
- Mic Battery: Lithium battery 14650 3.7V/1100mAh
- Mic Charging Time: 3-4 hours
- Mic Battery Life: 10 hours
- Receiver powered: DC 13.5V, 1000mA
- Working distance: Up to 80m
MICROPHONE OPERATION INSTRUCTION
- Volume +
- When adjusting the volume, the screen will display from U00 to U16.
- Volume –
- When adjusting the volume, the screen will display from U00 to U16.
- Note that when the volume is adjusted to U00, it will return to U12 for hearing protection next time it is turned on.
- Frequency Number
- CHA from CH000 to CH099. CHB from CH100 to CH 199.
- Current Frequency
- Microphone real-time battery level
- IR Infrared Pairing Window
- Power Switch with LED Indicator
- Press and hold for two seconds to turn on and off the microphone.
- The power indicator light is always green when the mic is turned on.
- Wireless Charging Point
STEPS TO PAIR
- Turn on the microphone and receiver.
- Recommended Automatic setting: Press and hold the set button for 2 seconds for CHA to automatically search for the best frequency. When the receiver selects the frequency, align the microphone IR window with the receiver IR window within 20cm. Click the set button, and wait for 3 seconds. When the frequencies of the microphone and receiver are consistent, pairing is successful. If unsuccessful, click the set button again and wait 3 seconds to pair again.
- Optional Manual setting: Click receiver up button 5 or down button 7 to choose the free frequency needed for CHA. Align the CHA IR window with the receiver IR window for CHA within 20cm. Click set button for CHA to pair. When the frequencies of the microphone and receiver are consistent, pairing is successful. If unsuccessful, click the set button again and wait 3 seconds to pair again.
- Repeat 2 or 3 step for others to finish pairing for CHB.
- The pairing steps of CHB are the same as CHA. When operating CHB, just follow the buttons on CHB.
- Multiple sets used together:
- Make sure all devices are turned off. Then turn on the first set of receivers and pair CHA and CHB according to step 2. Keep the paired microphone and receiver turned on.
- Later turn on the second set of receivers and repeat step 2, and so on. Please keep paired devices turned on until all devices are paired. It is recommended that up to 6-7 sets be used at the same time.
TROUBLESHOOTING
Turn on all the microphones, but one of them has on sound.
Reconnect the microphone and receiver according to the STEPS TO PAIR.
Received signal with noise or interference.
Change to other frequencies.
Check whether the receiving distance exceeds the maximum range.
Microphone cannot be turned on.
Check whether microphone is fully charged.
EU Declaration of conformity
RoHS Directive (2011/65/EU)
Hereby, Fujian EastWest Lifewit Technology Co.,LTD declares that the radio
equipment type TW790 is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the
following internet address:
https://www.tonormic.com/pages/eu-declaration-of-conf
Conditions and restrictions for using frequencies
Conditions and restrictions for using frequencies There may be special
conditions and restrictions for using frequencies in your country.
Before putting the product into operation, find the information for your
country at the following address: https://www.tonormic.com/pages/permitted-
frequency-bands
WARRANTY
TONOR provides 2 years of after-sales service, free replacement to products that are NOT damaged resulting from accident, alteration, misuse, negligence, or abuse. If exceeding 30 days of Amazon return policy, you can still contact us through our Shopify TONORMIC. We will serve you with full sincerity!
FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
ISED Statement
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
This device operates on a no-interference, no-protection basis. Should the user seek to obtain protection from other radio services operating in the same TV bands, a radio licence is required For further details, consult Innovation, Science and Economic Development Canada’s Client Procedures Circular CPC-2-1-28, Voluntary Licensing of Licence-Exempi Mireles Microphones in the I/Bands.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement
The device has been evaluated to meet general RF exposure requirement. The
device can be used in portable exposure condition without restriction.
ISED Radiation Exposure Statement
The device has been evaluated to meet general RF exposure requirement. The
device can be used installed and operated with minimum distance 0mm between
the radiator and your body.
Operating Frequency
CHA/100CH
CH000| 538.1| CH025| 545.6| CH050| 553.1| CH075| 560.6
CH001| 538.4| CH026| 545.9| CH051| 553.4| CH076| 560.9
CH002| 538.7| CH027| 546.2| CH052| 553.7| CH077| 561.2
CH003| 539| CH028| 546.5| CH053| 554| CH078| 561.5
CH004| 539.3| CH029| 546.8| CH054| 554.3| CH079| 561.8
CH005| 539.6| CH030| 547.1| CH055| 554.6| CH080| 562.1
CH006| 539.9| CH031| 547.4| CH056| 554.9| CH081| 562.4
CH007| 540.2| CH032| 547.7| CH057| 555.2| CH082| 562.7
CH008| 540.5| CH033| 548| CH058| 555.5| CH083| 563
CH009| 540.8| CH034| 548.3| CH059| 555.8| CH084| 563.3
CH010| 541.1| CH035| 548.6| CH060| 556.1| CH085| 563.6
CH011| 541.4| CH036| 548.9| CH061| 556.4| CH086| 563.9
CH012| 541.7| CH037| 549.2| CH062| 556.7| CH087| 564.2
CH013| 542| CH038| 549.5| CH063| 557| CH088| 564.5
CH014| 542.3| CH039| 549.8| CH064| 557.3| CH089| 564.8
CH015| 542.6| CH040| 550.1| CH065| 557.6| CH090| 565.1
CH016| 542.9| CH041| 550.4| CH066| 557.9| CH091| 565.4
CH017| 543.2| CH042| 550.7| CH067| 558.2| CH092| 565.7
CH018| 543.5| CH043| 551| CH068| 558.5| CH093| 566
CH019| 543.8| CH044| 551.3| CH069| 558.8| CH094| 566.3
CH020| 544.1| CH045| 551.6| CH070| 559.1| CH095| 566.6
CH021| 544.4| CH046| 551.9| CH071| 559.4| CH096| 566.9
CH022| 544.7| CH047| 552.2| CH072| 559.7| CH097| 567.2
CH023| 545| CH048| 552.5| CH073| 560| CH098| 567.5
CH024| 545.3| CH049| 552.8| CH074| 560.3| CH099| 567.8
CH100| 568.1| CH125| 575.6| CH150| 583.1| CH175| 590.6
CH101| 568.4| CH126| 575.9| CH151| 583.4| CH176| 590.9
CH102| 568.7| CH127| 576.2| CH152| 583.7| CH177| 591.2
CH103| 569| CH128| 576.5| CH153| 584| CH178| 591.5
CH104| 569.3| CH129| 576.8| CH154| 584.3| CH179| 591.8
CH105| 569.6| CH130| 577.1| CH155| 584.6| CH180| 592.1
CH106| 569.9| CH131| 577.4| CH156| 584.9| CH181| 592.4
CH107| 570.2| CH132| 577.7| CH157| 585.2| CH182| 592.7
CH108| 570.5| CH133| 578| CH158| 585.5| CH183| 593
CH109| 570.8| CH134| 578.3| CH159| 585.8| CH184| 593.3
CH110| 571.1| CH135| 578.6| CH160| 586.1| CH185| 593.6
CH111| 571.4| CH136| 578.9| CH161| 586.4| CH186| 593.9
CH112| 571.7| CH137| 579.2| CH162| 586.7| CH187| 594.2
CH113| 572| CH138| 579.5| CH163| 587| CH188| 594.5
CH114| 572.3| CH139| 579.8| CH164| 587.3| CH189| 594.8
CH115| 572.6| CH140| 580.1| CH165| 587.6| CH190| 595.1
CH116| 572.9| CH141| 580.4| CH166| 587.9| CH191| 595.4
CH117| 573.2| CH142| 580.7| CH167| 588.2| CH192| 595.7
CH118| 573.5| CH143| 581| CH168| 588.5| CH193| 596
CH119| 573.8| CH144| 581.3| CH169| 588.8| CH194| 596.3
CH120| 574.1| CH145| 581.6| CH170| 589.1| CH195| 596.6
CH121| 574.4| CH146| 581.9| CH171| 589.4| CH196| 596.9
CH122| 574.7| CH147| 582.2| CH172| 589.7| CH197| 597.2
CH123| 575| CH148| 582.5| CH173| 590| CH198| 597.5
CH124| 575.3| CH149| 582.8| CH174| 590.3| CH199| 597.8
| AT| BE| BG| CY| CZ| DE
---|---|---|---|---|---|---
DK| EE| EL| ES| FI| FR
HR| HU| IE| IT| LT| LU
LV| MT| NL| PL| PT| RO
SE| SI| SK| UK(NI)| |
FUJIAN EASTWEST LIFEWIT TECHNOLOGY CO.,LTD | RM
1201-1205, BLD 18, 2ND PHASE OF INNOVATION PARK, FUZHOU 350108, CHINA
EASTWEST ELECTRONIC COMMERCE CO US LIMITED | 3500
SOUTH DUPONT HIGHWAY, SUITE G106 DOVER, DE 19901 UNITED STATES
LIFEWIT LIMITED | UNIT 2, VINCENT HOUSE, FIRCROFT WAY, EDENBRIDGE UNITED
KINGDOM
Life wit GmbH | Friedenstraße 5 97072 Wuerzburg Germany
Customer Support
https://www.tonormic.com
support@tonormic.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>