Westinghouse WH24.07 Vintage 52 Inch Ceiling Fan Owner’s Manual

August 21, 2024
Westinghouse

Westinghouse WH24.07 Vintage 52 Inch Ceiling Fan

Specifications:

  • Model: ETL-ES-Vintage-WH24.07
  • Product Name: Vintage
  • Net Weight: 16.10 LBS (7.30 KGS)

Product Usage Instructions

Safety Tips:

  • Installation work and electrical wiring must be done by qualified person(s) by all applicable codes and standards (ANSI/NFPA 70), including fire-rated construction.
  • Use this unit only in the manner intended by the manufacturer. Contact the manufacturer for any questions.
  • After making wire connections, push connections into outlet box with wire nuts pointing up. Spread wires apart with grounded and equipment-grounding conductor on one side and ungrounded conductor on the other side.
  • Before installing the fan, switch off power at the service panel and lock service disconnecting means to prevent accidental power switching.

Vaulted Ceiling Installation:

  • Low Ceilings: Follow instructions for normal ceilings.
  • Normal Ceilings: Install mounting bracket to outlet box in ceiling using the screws and washers provided with the outlet box.

Note : For pitched ceiling installation, refer to westinghouselighting.com for specially designed canopy kit options.

Combo-Blade:

Combo-Blades feature two high-quality finishes on one blade. Select the one that complements your decor or change the style with a flip of the blade.
Note : Combo-Blade finishes vary depending on the model.

Mounting Instructions:

  1. Use a metal outlet box suitable for fan support (must support 35 lbs).
  2. Before attaching the fan to the outlet box, ensure the box is securely fastened by at least two points to a structural ceiling member.
  3. Carefully lift fan assembly onto mounting bracket.
  4. Rotate the fan until the notch on the downrod ball engages the ridge on the mounting bracket for hands-free wiring.

FAQ:

Q: Do I need to consult an electrician for installation?
A: Yes, installation work and electrical wiring must be done by qualified person(s) following all applicable codes and standards.

Vintage
Please write model number here for future reference: Por favor, incluya el número del modelo aquí para futura referencia:

Net Weight : 16.10 LBS
Peso Neto : 7.30 KGS

SAFETY TIPS

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR PERSONAL INJURY, MOUNT TO OUTLET BOX MARKED ‘ACCEPTABLE FOR FAN SUPPORT OF 35 LBS (15.9 KG) OR LESS’ AND USE MOUNTING SCREWS PROVIDED WITH THE OUTLET BOX AND/OR SUPPORT DIRECTLY FROM BUILDING STRUCTURE. MOST OUTLET BOXES COMMONLY USED FOR THE SUPPORT OF LUMINARIES ARE NOT ACCEPTABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED. CONSULT A QUALIFIED ELECTRICIAN IF IN DOUBT.

  1. Installation work and electrical wiring must be done by a qualified person(s) by all applicable codes and standards (ANSI/NFPA 70), including fire-rated construction.
  2. Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.
  3. After making the wire connections, gently push connections into the outlet box with wire nuts pointing up. The wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.
  4. Before you begin installing the fan, switch the power off at the service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
  5. Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
  6. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
  7. Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade.
  8. To reduce the risk of fire, electric shock, or personal injury, this fan must be mounted to an outlet box marked suitable for fan support, and use the mounting screws provided with the outlet box. (Mounting must support at least 35 lbs.)
  9. WARNING! Do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating blades.
  10. Attach the mounting bracket using only the hardware supplied with the outlet box. Fan is only to be mounted to an outlet box marked “Acceptable for Fan Support”.
  11. WARNING! To reduce the risk of fire or electric shock, do not use this fan with any solid-state fan speed control device, or variable speed control.
  12. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
  13. NEVER place a switch where it can be reached from a tub or shower.
  14. The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
  15. Before servicing or cleaning unit, switch the power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
  16. All set screws must be checked and re-tightened where necessary before installation.
  17. The appliance is not intended for use by young children or infirmed persons without supervision. Young children should be supervised to ensure they do not play with the appliance.

TOOLS REQUIRED

  • Phillips Screwdriver
  • Wire Cutters
  • Pliers
  • Step Ladder

FEATURES

  • FLUSH MOUNT INSTALLATION
    • For low ceilings
  • DOWNROD INSTALLATION
    • For normal ceilings
  • VAULTED CEILING INSTALLATION
    • May require a longer downrod

Note : For pitched ceiling installation, please refer to westinghouselighting.com for specially designed canopy kit options.

COMBO-BLADE
Combo-Blades feature two high quality finishes on one blade. Select the one that best complements your decor, or change the style with just a flip of the blade.
NOTE : Combo-Blade finishes vary, depending upon model.

PREPARING FOR INSTALLATION

  • Unpack and inspect fan carefully to be certain all contents are included. Turn off power at fuse box to avoid possible electrical shock
  • Use metal outlet box suitable for fan support (must support 35 lbs). Before attaching fan to outlet box, ensure the outlet box is securely fastened by at least two points to a structural ceiling member (a loose box will cause the fan to wobble).
  • Remove the screws and star washers from the two mating holes (1) on the canopy. Loosen (do not remove) the screws in the mating slots (2) on the canopy. Rotate the mounting bracket and remove from the canopy.

MOUNTING BRACKET INSTALLATION

Install mounting bracket to outlet box in ceiling using the screws and washers provided with the outlet box

NORMAL DOWNROD OPTION

Remove clamp pin (1) and cross pin (2) from downrod (3).

NORMAL DOWNROD OPTION

Feed motor lead wires through downrod/canopy assembly and insert downrod into downrod yoke. Make sure to align hole in downrod with the hole in downrod yoke. Install yoke cross pin (1) through yoke and downrod. Insert clamp pin (2) into cross pin until it snaps into place. Tighten set screws (3) in yoke. SEE APPENDIX FOR ALTERNATE INSTALLATION OPTIONS.

MOUNTING

  • Carefully lift fan assembly onto mounting bracket. Rotate fan until notch on downrod ball (1) engages the ridge on the mounting bracket (2). This will allow for hands free wiring.
  • With bracket holding fan assembly, make electrical connections using the following step for wiring instructions.

WIRING OPTIONS

  • Follow diagram above to make wiring connections for fan pull chain control.
  • Follow diagram above to make wiring connections for wall control operation.

SECURE TO CEILING

For flush mount fans, carefully lift fan from the mounting bracket, making sure not to break any wire connections. For downrod fans, slide the canopy up to the mounting bracket.
The canopy has two mating slots (1) and two mating holes (2). Position both slots on canopy directly under and in line with two screws in the mounting bracket (3). Lift the canopy, allowing the two screws and star wahers to slide into the mating slots. Rotate the canopy clockwise until both screws from the mounting bracket drop into the slot recesses. Tighten screws securely. Install two screws and star washers into the mating holes of the canopy and tighten to secure the canopy to the mounting bracket.

BLADE INSTALLATION

  • Attach blade brackets to blades using the blade bracket screws (1) and fabric washers (2).
  • Check the motor for plastic shipping stabilizer tabs (1), and remove them if they are present. Attach blade assembly to motor using the noise-dampening motor gaskets (2) and motor screws provided. Tighten screws securely.
    NOTE : Some models do not utilize motor gaskets, washers, or stabilizer tabs

LIGHT FIXTURE INSTALLATION

  • Find the two wires from the switch housing with the tag that says FOR LIGHT. Connect the blue wire from the switch housing to the black wire from the light kit, and connect the white wire from the switch housing to the white wire from the light kit. Attach light kit to the switch housing using three small screws provided.
  • Install shades to light kit by finger-tightening the screws for each shade holder as shown. Do not overtighten screws. Install light bulbs (included).
  • Assemble decorative fob and extension chains from hardware bag to fan pull chains by inserting end of chain into chain coupling. Confirm chains are held by lightly pulling both chains in coupling.

Appendix for alternate installation options

  • FLUSH MOUNT OPTION (see page #: 16)
  • EXTENDED DOWNROD OPTION (see page #: 17)

FLUSH MOUNT OPTION

  • Guide motor wires through the base of the canopy as shown and attach the canopy directly to top of motor housing with flush mount screws and lock washers provided. Tighten screws securely
  • For flush mount option, raise fan assembly and place it onto hook from the mounting bracket into a closed hole on the canopy. This will allow for hands-free wiring. PROCEED DIRECTLY TO PAGE 11 FOR WIRING OPTIONS.

EXTENDED DOWNROD OPTION

  • Loosen downrod ball (1) from downrod (2) by removing set screw (3).
  • Slide downrod ball (1) off of downrod and remove pin (2).

Re-install pin into the extended downrod, and slide the downrod ball up to the top of the downrod. Re-install set screw to secure ball to the downrod. Note: Some extended downrods have a pre-drilled set-screw hole. If a pre-drilled hole is present in the extended downrod, tighten the set screw into the pre- drilled hole in the extended downrod. If no pre-drilled hole exists in the extended downrod, tighten the set screw against the downrod to secure the downrod ball.
Feed motor lead wires through downrod/canopy assembly and insert downrod into downrod yoke. Make sure to align hole in downrod with the hole in downrod yoke. Install yoke cross pin (1) through yoke and downrod. Insert clamp pin (2) into cross pin until it snaps into place. Tighten set screws (3) in yoke. PROCEED TO PAGE 10, STEP 7.

OPERATION AND MAINTENANCE

Operation

  • Turn on the power and check operation of fan. The pull chain controls the fan speeds as follows: 1 pull – high; 2 pulls – medium; 3 pulls – low; 4 pulls – off. Speed settings for warm or cool weather depend on factors such as room size, ceiling height, number of fans and so on. The slide switch controls direction, forward or reverse.
  • Warm weather/down position – (Forward) Fan turns counterclockwise direction. A downward air flow creates a cooling effect as shown in illustration A. This allows you to set your air conditioner on a higher temperature setting without affecting your comfort.
  • Cool weather/up position – (Reverse) Fan turns clockwise direction. An upward airflow moves warm air off the ceiling area as shown in illustration
  • B. This allows you to set your heating unit on a lower setting without affecting your comfort.
    NOTE : Turn off and wait for fan to stop before changing the setting of the forward/reverse slide switch.

Maintenance

  1. Because of the fan’s natural movement, some connections may become loose. Check the support connections, brackets, and blade attachments twice a year. Make sure they are secure.
  2. Clean your fan periodically to help maintain its new appearance over the years. Do not use water when cleaning. This could damage the motor, or the wood, or possibly cause electrical shock.
  3. Use only a soft brush or lint-free cloth to avoid scratching the finish. The plating is sealed with a lacquer coating to minimize discoloration or tarnishing.
  4. There is no need to oil your fan. The motor has permanently lubricated bearings.

TROUBLESHOOTING GUIDE

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, please check this Trouble Shooting Chart. If a problem cannot be remedied, please consult with your qualified electrician and do not attempt any electrical repairs yourself.

TROUBLE SUGGESTED/REMEDY

  1. If fan does not start:

  2. check main and branch circuit fuses or circuit breakers.

  3. check wire connections as performed in step #9 or #10 of the installation.
    CAUTION : Make sure main power is turned off.

  4. Make sure forward/reverse switch is firmly in up or down position. Fan will not operate when switch is in the middle.

  5. If the fan still will not start, contact a qualified electrician.
    Do not attempt to troubleshoot internal electrical connections yourself.

  6. If fan sounds noisy:

  7. check to make sure all screws in motor housing are snug (not over-tightened).

  8. check to make sure the screws which attach the fan blade holder to the motor are tight.

  9. Some fan motors are sensitive to signals from Solid State variable speed controls. DO NOT USe a Solid State variable speed control.

  10. Allow a “break-in” period of 24 hours. Most noises associated with a new fan will disappear after this period.

  11. If fan wobbles:
    All blades are weighed and grouped by weight. Natural woods vary in density which could cause the fan to wobble even though all blades are weight-matched. The following procedures should eliminate most of the wobble. check for wobble after each step.

  12. check that all blades are screwed firmly into blade holders.

  13. check that all blade holders are tightened securely to motor.

  14. Make sure that canopy and mounting bracket are tightened securely to ceiling joist.

  15. If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can redistribute the weight and possibly result in smoother operation.

  16. If light does not work:

  17. check to see that the wire connections in the switch housing are connected.

  18. check for faulty light bulbs.

  19. If light kit will still not operate, contact a qualified electrician for assistance.

WARRANTY

This Westinghouse Lighting Fan offers a Limited Lifetime Warranty to the original owner against defects in material and workmanship. This warranty is in lieu of all other warranties expressed or implied. Westinghouse Lighting will repair or replace the parts needed, and/or, replace the ceiling fan, if the defective is due to faulty materials or workmanship.

  • Years 1 & 2 – Westinghouse Lighting will repair or replace this ceiling fan.
  • After Year 2 – Warranty is limited to the motor.

This warranty does not cover acts of nature such as lightning damage, or corrosion and discoloration of components, nor does it cover damages caused through abuse, improper installation, surges in electric current, or acts of third parties. This warranty does not cover broken glass after installation. If this ceiling fan fails during the warranty period, return defective product to seller. Warranty terms and conditions of sellerr apply. If replacement product is not available through seller, please contact www.westinghouselighting.com/contact-us.

PARTS LIST

  1. Mounting Bracket
  2. Blade Bracket
  3. Blade
  4. Glass
  5. Fan Speed Switch
  6. Light Control Switch
  7. Capacitor
  8. Hardware Pack

Westinghouse Lighting, Philadelphia, PA 19154-1029, U.S.A.
www.westinghouselighting.com
and Westinghouse are trademarks of Westinghouse Electric Corporation.
Used under license by Westinghouse Lighting.
All Rights Reserved.
Made in China

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Westinghouse User Manuals

Related Manuals