MEAN WELL PID-250 250W Isolated Dual Output Power Supply Owner’s Manual

August 12, 2024
MEAN WELL

MEAN WELL PID-250 250W Isolated Dual Output Power Supply

Specifications

  • Model:
    • PID-250A
    • PID-250B
    • PID-250C
    • PID-250D
  • Output Number:
    • CH1, CH2
    • CH1, CH2
    • CH1, CH2
    • CH1, CH2
  • DC Voltage:
    • 12V, 5V
    • 24V, 5V
    • 36V, 5V
    • 48V, 5V

Product Usage Instructions

Installation

  1. Ensure the input voltage matches the specified range (90 ~ 264VAC).
  2. Connect the DC output terminals (CH1, CH2) to your devices following the correct polarity.

Operation

  1. Power on the device by connecting it to a suitable power source.
  2. Use the remote control for CH1 if needed.

Maintenance
Regularly check for dust accumulation and ensure proper ventilation around the product for cooling.

FAQ

  • Q: What is the input efficiency of the PID-250 model?
    A: The input efficiency is typically 83% for this model.

  • Q: How many years of warranty does the product come with?
    A: The product comes with a 3-year warranty.

250W Isolated Dual Output with PFC Function
PID-250

Features

  • Universal AC input / Full range
  • Isolated output & GND for CH1,CH2
  • Built-in active PFC function, PF>0.92
  • Protections:Short circuit / Overload / Over voltage / Over temperature
  • Remote control for CH1
  • Peak load 170% for CH1 within 10 sec.
  • Cooling by free air convection
  • 100% full load burn-in test
  • 2 vears warranty

GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx

MEAN-WELL-PID-250-250W-Isolated-Dual-Output-Power-Supply-
\(2\)

SPECIFICATION

MODEL PID-250A PID-250B PID-250C PID- 250D
OUTPUT OUTPUT NUMBER CH1 CH2 CH1
DC VOLTAGE 12V 5V 24V 5V
RATED CURRENT 15A(Peak 20A) 5A 9.4A(Peak 16.7A) 5A
11.1A) 5A 4.7A(Peak 8.4A) 5A
CURRENT RANGE Note.6 0 ~ 15A (Peak 20A) 0 ~ 5A 0 ~ 9.4A (Peak
16.7A) 0 ~ 5A 0 ~ 6.3A (Peak 11.1A) 0 ~ 5A 0 ~ 4.7A (Peak 8.4A)
RATED POWER 205W 250.6W 251.8W 250.6W
RIPPLE & NOISE (max.) **Note.2** 120mVp-p 50mVp-p 150mVp-p 50mVp-p
200mVp-p 50mVp-p 200mVp-p 50mVp-p
VOLTAGE ADJ. RANGE 10.8 ~ 13.2V 4.75 ~ 5.25V 21.6 ~ 26.4V 4.75 ~
5.25V 32.4 ~ 39.6V 4.75 ~ 5.25V 43.2 ~ 52.8V 4.75 ~ 5.25V
VOLTAGE TOLERANCE Note.3 ±3.0% ±2.0% ±2.0% ±2.0%
±2.0% ±2.0% ±2.0%
LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±1.0% ±2.0% ±1.0% ±2.0%
SETUP, RISE TIME 2500ms, 60ms/115VAC       1200ms, 60ms/230VAC
HOLD UP TIME (Typ.) 30ms at full load
INPUT VOLTAGE RANGE Note.5 90 ~ 264VAC           127 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR PF≧0.92/230VAC            PF≧0.97/115VAC at full load
EFFICIENCY(Typ.) 83% 86% 86% 86%
AC CURRENT (Typ.) 3A/115VAC         1.5A/230VAC
INRUSH CURRENT (Typ.) COLD START 58A/230VAC
LEAKAGE CURRENT <3.5mA / 240VAC
PROTECTION OVERLOAD
  • CH1: 105 ~ 170% rated output power
  • Normally work within 10 sec and then shut down, re-power on to recover
  • Over 180% rated power or short circuit, constant current limiting within 10 sec and then shut down, re-power on to recover

CH2: 101 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| 13.8 ~ 16.2V| 5.5 ~ 6.75V| 27.6 ~ 32.4V| 5.5 ~ 6.75V| 40 ~ 48V| 5.5~ 6.75V| 54 ~ 64.8V| 5.5 ~ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover for CH1 ; Hiccup mode, recovers automatically afer fault condition is removed for CH2(by zener diode clamp)
OVER TEMPERATURE| Shut down o/p voltage(CH1), recovers automatically after temperature goes down
FUNCTION| REMOTE CONTROL| CN52 : Open=CH1 & CH2 power on ; Short = CH1 power off, CH2 power on; when CH2 is malfunction, CH1 will be shut down
**ENVIRONMENT| WORKING TEMP.| -20 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -20 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.05%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min each along X, Y, Z axes
SAFETY & EMC **(Note 4)| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC  I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2, heavy industry level,  EAC TP TC 020
OTHERS| MTBF| 2091.7K hrs min.       Telcordia SR-332 (Bellcore) ; 150.5K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION| 2229540mm (LWH)
PACKING| 0.74Kg; 18pcs/14.3Kg/0.98CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EM testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  5. Derating may be needed under low input voltage. Please check the derating curve for more details.
  6. Peak current should reduce to 150% of rated value if the input voltage <110VAC.
  7. Heat Sink HS1,HS2,HS3 can not be shorted.
  8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
    Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

MEAN-WELL-PID-250-250W-Isolated-Dual-Output-Power-Supply-
\(3\)

Unit:mm

AC Input Connector (CN1) : JST B5P-VH or equivalent

Pin No. Assignment Mating Housing Terminal
1 FG
2,4 No Pin
3 AC/N
5 AC/L

: Grounding Required
DC Output Connector (CN51) : JST B10P-VH or equivalent

Pin No. Assignment Mating Housing Terminal
1,2,3 COM1 JST VHR or equivalent JST SVH-21T-P1.1 or equivalent
4,5,6 V1
7,8 COM2
9,10 V2

Remote ON/OFF Connector(CN52):JST B2B-XH or equivalent

Pin No. Status Mating Housing Terminal
PIN1,2 (Short) V1: OFF V2: ON JST XHP or equivalent JST SXH-001T-P0.6 or

equivalent
PIN1,2 (Open)| V1: ON V2: ON
SVR1| For CH1
---|---
SVR2| For CH2

  1. HS1,HS2,HS3 cannot be shorted.
  2. CN1:Pin1 is safety ground. For better EMC performance,Please secure an electrical connection between M1,M2,M3,and chassis grounding.

Block Diagram

MEAN-WELL-PID-250-250W-Isolated-Dual-Output-Power-Supply-
\(5\)

Derating Curve

MEAN-WELL-PID-250-250W-Isolated-Dual-Output-Power-Supply-
\(6\)

Output Derating VS Input Voltage

MEAN-WELL-PID-250-250W-Isolated-Dual-Output-Power-Supply-
\(7\)

File Name :PID-250-SPEC 2024-02-23

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>