Tazpi TPS30 Professional Under Cabinet Range Hood User Manual

May 15, 2024
Tazpi

Professional Under Cabinet Range Hood
Installation Guide & Users ManualTazpi TPS30 Professional Under Cabinet
Range Hood Model Name: TPS30

TPS30 Professional Under Cabinet Range Hood

NOTICE:
For residential use only.
Installer: Leave this guide with the homeowner.
Homeowner: Keep this guide for future reference.
E-mail address: support@tazpi.com
Phone number:1-252-772-1994(US)

THANK YOU FOR YOUR PURCHASE
Thank you for your purchase. We know that you have many brands and products to choose from and we are honored to know that you have decided to take one of our products into your home and hope that you enjoy it.
We follow the mostadvanced manufacturing philosophy. Each appliance leaves the factory afterthorough quality inspection and testing. We are ready to answer anyquestions you may have regarding how to install, use and care for yourproducts. We hope that this manual will help you learn to use the product inthe safest and most effective manner.
If you have any questions or concerns, please contact our Customer Support at: support@tazpi.com

IMPORTANT SAFETY INSTRUCTIONS

Read all instructions before using this appliance.
Save these instructions for future references
Approved for residential appliances
For residential use only
IMPORTANT SAFETY INSTRUCTIONS

**CAUTION
** FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS OR VAPORS.

CAUTION
To reduce risk of fire and to properly exhaust air, do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces, or garages.

WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT WORK. Install this hood in accordance with all requirements specified.

**WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:**
A. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer
B. Before servicing or cleaning the unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
C. Installation Work and Electrical Wiring Must Be Done By Qualified Person(s) In Accordance With all Applicable Codes & Standards, Including Fire-rated Construction.
D. Sufficient air is needed for proper combustion and exhausting of gases through the flue (Chimney) of fuel burning equipment to prevent back- drafting. Follow the heating equipment manufacturers guideline and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
E. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
F. Ducted systems must always be vented to the outdoors.

**WARNING
GROUNDING INSTRUCTIONS
** This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.

WARNING – IMPROPER GROUNDING CAN RESULT IN A RISK OF ELECTRIC SHOCK.
Consult a qualified electrician if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded.
Do not use an extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the appliance.

WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS, IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:
A. SMOTHER FLAMES with a close – fitting lid, cookie sheet, or other metal tray, then turn off the gas burner or the electric element. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE EPARTMENT.
B. NEVER PICK UP A FLAMING PAN – you maybe DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result. Always leave safety grills and filters in place.Without these components, operating blowers could catch onto hair, fingers and loose clothing. The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due  to negligence and the warranty of the unit automatically expires due to improper maintenance.

WARNING
To Reduce The Risk Of Fire Or Electric Shock, DoNot Use This Hood With Any External Solid State Speed Control Device.

WARNING
Unplug or disconnect the appliance from the power supply before servicing.

ALUMINUM FILTERS

Tazpi TPS30 Professional Under Cabinet Range Hood - Aluminum
Filters

About Your New Filters
Aluminum Filters are recommended to be replaced every 6 months depending on usage.

Cleaning my Aluminum Filters
Your filters can be hand washed and cleaned to increase time between replacements. Aluminum Filters may not be placed in the dishwasher.

PARTS DIAGRAM

MODEL: TPS30Tazpi TPS30 Professional Under Cabinet Range Hood - Parts
Diagram

Other accessories:

1. 3-Speed Mechanical Control
2. LED Lights (2 pcs)
3. Motor Housing
4. Main Body
5. Aluminum Filter (2 pcs)
6.Carbon Filter (1 pcs)| 7. Smoke tube (1 pcs)
8. Duct Clamps (1 pcs)
9. Duct Connection Fitting with Damper (1 pcs)
10. Air Outlet Cap (2 pcs)
11. Screws 5mm x 49mm (4 pcs)
12. Wall Anchors 10mm x 43.3mm (4 pcs)
---|---

INSTALLATION REQUIREMENTS

  1. Please read the following instructions carefully.
  2. This Range Hood can be vented through the top or back. Remove the Air Outlet Cap according to the option chosen (Fig. 1). For ductless installation, install an Air Outlet Cap on both the rear and top vent holes.
  3. For optimal performance the Range Hood must be installed 24″ – 36″ in height from the cooktop. (Fig. 2)
  4. Electrical Requirements: Rated Voltage and Frequency:) 110-120V~ 60Hz. Motor Input Power: 65W

TOOLS NEEDED FOR INSTALLATIONTazpi TPS30 Professional Under Cabinet
Range Hood - Tools Needed

WARNING
Sufficient air is needed for proper combustion and exhausting of gases through the chimney of fuel burning equipment to prevent back- drafting. Follow the cooking equipment manufacturers guideline and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and local code. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. Ducted systems must always be vented outdoors.

Tazpi TPS30 Professional Under Cabinet Range Hood -
Figure

PRE-INSTALLATION PROCEDURES

  • Please read the instructions carefully. Unpack the Range Hood and check that all functions are working before installing.
  • Ensure that the voltage (V) and the frequency (Hz) indicated on the sticker match the voltage and frequency at the installation site.
  • Check that the area behind the installation surface to be drilled is clear of any electrical cables or pipes, etc.
  • The stainless steel surfaces of the Range Hood are very easily damaged during installation if scratched or bumped by tools. Please take care to protect the surfaces during installation.
  • Protect the cook top surface below with cardboard, or the like, to prevent damage occurring during installation.
  • The manufacturer shall not be held liable for failure to observe all safety regulations.

IMPORTANT READ BEFORE INSTALLATION
You will need to set the Range Hood mode to either Ducted or Ductless.

  1. Remove Aluminum Filters
  2. Locate Knob Settings located under the Motor (Fig. 1)
  3. Unlock the Settings Knob by unscrewing and setting to Ducted or Ductless mode.
  4. Lock the Knob into place by replacing the screw from Step 3.

Tazpi TPS30 Professional Under Cabinet Range Hood -
Filters

INSTALLATION INSTRUCTIONS

CAUTION: HOOD MAY HAVE VERY SHARP EDGES: PLEASE WEAR PROTECTIVE GLOVES WHENEVERIT IS NECESSARY TO REMOVE ANY PARTS FOR INSTALLING,CLEANING OR SERVICING.

Cabinet Installation Method
For Ducted installation drill a 130mm diameter hole into the cabinet and four 3.5mm diameter holes as pictured below picture.
For Ductless installation do not drill the 130mm diameter hole in the cabinet. Drill only the four 3.5mm diameter holes as pictured below.
Use the 4 screws to mount the Range Hood to the cabinet. Check that your mounting screws are in the correct place by temporarily fitting the Range in place. If correct, lock into position by pushing in the Range Hood.

Tazpi TPS30 Professional Under Cabinet Range Hood - Cabinet
Method

CAUTION: HOOD MAY HAVE VERY SHARP EDGES: PLEASE WEAR PROTECTIVE GLOVES WHENEVERIT IS NECESSARY TO REMOVE ANY PARTS FOR INSTALLING,CLEANING OR SERVICING.

Wall Mount Installation Method
A. Find the 4 mounting holes in the back of the range hood. Mark their locations at the installation location with a pencil or marker.
B. Drill 5/16 (8mm) hole at each of the marked locations.
C. Insert anchors along with screws into each drilled hole. Firmly tighten the screw into place.
D. Hang your Range Hood into place by aligning the screws with the 4 mounting holes in the back of the range hood. Lock into place by sliding down the range hood.

Tazpi TPS30 Professional Under Cabinet Range Hood - Wall
Mount

PREPARING THE VENT HOOD: AIR RECIRCULATION MODE

Installing the Carbon FilterTazpi TPS30 Professional Under Cabinet
Range Hood - Carbon Filter

  1. Remove the aluminum filters.
  2. The charcoal filter is installed at the end of the motor. Align the upper and lower holes, twist the carbon filter Counterclock wise to lock into place.
  3. To replace the carbon filter, reverse the process and repeat.

NOTE: The carbon filter cannot be washed and reused and must be replaced every 4-6 months, depending on use.
If you have any questions about Installing the Carbon Filter, please feel free to contact our Customer Support at: support@tazpi.com, and we will provide you with ttre video toinstall it properly.

Check Valve Installation and Plugs
PREPARING THE VENT HOOD: AIR EXTRACTION MODE

Check Valve Installation and Plugs
Hold on check valve with your hands, align the box gap, put in the check vaive , and then spin to a certain angle until three anglesof the valve are stuck. Installation is complete.
Install a port plug in the unused hole on the vent hood (top or back).

If you have any questions about the Installing the Duct Connection Fittingwith Damper, please feel free to contact our Customer Support at: support@tazpi.com, and we will provide you with the video to install itproperly.

OPERATING INSTRUCTIONS

3-Speed Mechanical ControlTazpi TPS30 Professional Under Cabinet Range
Hood - Mechanical Control

Note: For best results, turn fan on prior to any preparation or cooking and keep fans running while cooking. Adjust speed as needed.

Button Control
= Turns the range hood ON/OFF.
= Lowest fan speed (QuietMode)
= Middle fan speed (Low)
= Highest fan speed (High)
= Turns the lights ON/OFF

Power Control
To turn the hood off, press the button once while it is ON.

Speed Control
Press the speed buttons ( , and ) to increase/decrease the fan speed level.

Light Control
Press the light button to turn ON/OFF the lights

MAINTENANCE

CAUTION: NEVER PUT YOUR HAND INSIDE OF THE UNIT WHILE ITS OPERATING. FOR THE BEST PERFORMANCE CLEAN YOUR RANGE HOOD REGULARLY.
CLEANING

  1. Use only mild soap or cleaning solutions to clean the hoods outer surface. Dry surfaces using a soft cloth.
  2. Stainless Steel cleaner may be used on the external surface.
  3. Clean the Range Hood assembly 3 to 6 months depending on use.
  4. DO NOT clean the motor or electrical components with water or any other liquid.

Replacing LED 3W 12V Light Fixture

  1. Remove the aluminum filters
  2. Make sure the range hood is unplugged or turn OFF breaker and the lights are cool to touch.
  3. Place a flat-head screwdriver between light housing and hood body.
  4. Gently pry up the light housing and search for the metal clip.
  5. Apply force to the metal clip and pull out the light fixture.
  6. Disconnect the power cable and discard the old light fixture.
  7. Reverse the steps to install a new LED light fixture.
  8. Reinstall the aluminum filters.
  9. Turn ON breaker and range hood to test for operation.

Tazpi TPS30 Professional Under Cabinet Range Hood - Light
Fixture

TROUBLESHOOTING

CAUTION: ALWAYS UNPLUG UNIT FROM POWER BEFORE SERVICING

PROBLEM SOLUTION TOOLS
My range hood is noisy. A. Check inside the range hood for any loose debris
and remove. Phillips Screwdriver
My range hood has poor performance. A. The range hood and cook top are too

far away from each other. Optimal distance is 24″ to 36″
B. There are too many open windows or doors in the area. Close some doors or windows.
C. The motor performance has decreased due to wear. Replace motor.
D. Check and make sure the tape holding down the damper flaps at the vent hole are removed before use.| Phillips Screwdriver
My range hood shakes.| A. The installation is not secure. Check again and make sure the installation hardware is securely mounted.
B. The fan is broken or not balanced. Realign or replace fan.
C. The motor is loose. Check and make sure the motor is solidly mounted to the unit.| Phillips Screwdriver
The motor no longer runs.| A. Replace control panel or circuit board.
B. Replace with new motor assembly.| Phillips Screwdriver
Light bulb went out.| A. Replace with a new LED Bulb 3watt max.| Phillips Screwdriver

MEASUREMENNTS & DIAGRAMS

All inch measurements are converted from millimeters.Inch measurements are estimated.
All measurements in ( ) are millimeters.
MODEL NO.: TPS30

Tazpi TPS30 Professional Under Cabinet Range Hood -
Diagrams

WARRANTY AND SERVICE

Warranty Period

  1. Customers are entitled to replacement or free repair service in case of quality defect(s) found in the product within 15 days upon receipt of the product.
  2. Customers are entitled to free repair service from us for any product proven defective in material or workmanship that results in product failure during normal consumer usage and conditions within the valid warranty period, which is 12 months counting from the date of selling. However warranty period varies by product component and country of purchase. Please contact our after-sales service team via support@tazpi.com for detailed warranty information.

Warranty Exclusions

  1. Products subjected to unauthorized repair, misuse, collision, neglect. mishandling, soaking, accident, and unauthorized alteration.
  2. Products subjected to improper use or whose labels or security tags have been torn off or altered.
  3. Products whose warranty has expired.
  4. Products damaged due to force majeure, such as fire, flood, lightening, etc.

Warranty Claim Procedure

  1. If failure or any problem occurs to your product after purchase, please contact us, or you can always contact our customer service through email at support@tazpi.com.
  2. Our customer service will guide you through the whole service procedure regarding any product issue or problem you have encountered. We reserve the right to reexamine damaged or returned products.

Contact Card
E-mail:support@tazpi.com
Phone: 1-252-772-1994(US) Mon-Sat 10am-6pm(PST)

Correct Disposal of this product:
This marking indicates that this appliance should not be disposedwith other household wastes. To prevent possible harm to theenvironment or human health from uncontrolled waste disposalrecycle it responsibly to promote the sustainable reuse of materiaresources.sustainable reuse of materiaresources.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals