DAUDIN GFGW-RM01N Remote I-O Module System User Manual
- June 11, 2024
- DAUDIN
Table of Contents
- DAUDIN GFGW-RM01N Remote I-O Module System User Manual
- 1. Remote I/O Module System Configuration List
- Product Description
- Siemens S7-200 Smart Connection Setup
- __ i-Designer Program Setup
- Note:
- Siemens S7-200 Smart Hardware Connections
- Siemens S7-200 Smart Connection Setup
- Communication protocol settings
- ames & Definitions
- Command Memory Configurations
- Sample Program
- Read More About This Manual & Download PDF:
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DAUDIN GFGW-RM01N Remote I-O Module System User Manual
1. Remote I/O Module System Configuration List
Part No. | Specification | Description |
---|---|---|
GFGW-RM01N | Modbus TCP-to-Modbus RTU/ASCII, 4 Ports | Gateway |
GFMS-RM01S | Master Modbus RTU, 1 Port | Main Controller |
GFDI-RM01N | Digital Input 16 Channel | Digital Input |
GFDO-RM01N | Digital Output 16 Channel / 0.5A | Digital Output |
GFPS-0202 | Power 24V / 48W | Power Supply |
GFPS-0303 | Power 5V / 20W | Power Supply |
0170-0101 | 8 pin RJ45 female connector/RS-485 Interface | Interface Module |
Product Description
- The interface module can convert the gateway’s RS485 port into a RJ45
- The main controller is in charge of the management and dynamic configuration of I/O parameters and so on.
- The power module and interface module are standard for remote I/O’s and users can choose the model or brand they prefer.
Siemens S7-200 Smart Connection Setup
This section details how to connect a gateway to Siemens S7-200 Smart. For detailed information regarding , please refer to the _ -Series Product Manual_
__ i-Designer Program Setup
-
Make sure that the module is powered and connected to the gateway module using an Ethernet cable
-
Gateway Module IP Settings
**** Note: The IP address must be in the same domain as the controller equipment
Note:
Set Group 1 as Slave and set the gateway to use the first set of RS485 port to connect to the main controller (GFMS-RM01N)
Siemens S7-200 Smart Hardware Connections
This chapter explains how to use the Step7-MicroWINSMART program to connect S7-200 Smart to . The software must be V2.4 or above for Modbus TCP support. For detailed information, please refer to the S7-200 SmartSeries Manual
- Modbus TCP connects with the gateway via the Ethernet cable going through the Ethernet port on the S7-200 Smart\
Siemens S7-200 Smart Connection Setup
- Launch Step7-MicroWINSMART and click on “Commands” on the right side of the program
****| A. Click on the “Commands” menu
B. Click on the “Bases” menu
C. Click on the “Modbus TCP Client” menu
D. Click to add a new “MBUS_CLIENT”
---|---
Communication protocol settings
ames & Definitions
| Names| Function
---|---|---
A| EN| Enable bits
B| Req| When it is “1”, it means to send Modbus requests to the server
C
|
Connec t
| When it is “1”, it will attempt to connect to the assigned IP address;
When it is “0”, it will disconnect and ignore any requests from the “Req” command
D
| IP Add 1~4|
Gateway IP address
E| IP Port| The gateway’s port number, which is 502
F| RW| Operating modes. “0” is “Read” and “1” is “Write”
G| Addr| Read/Write Modbus’ starting address
H| Count| Length of the data to be read/written
I| DataPtr| Address where the data is stored
J| Done| Completed bits
K| Error| Error Code
Command Memory Configurations
| A. Click on the “Memory” menu
B. Set up a command’s starting address and once finished, click on “Confirm”
---|---
Notes:
※ ’s first GFDI-RM01N has the
register address at 1000(HEX) converted to 4096(DEC)+1 and the starting
address at 44097
※ ’s first GFDO-RM01N has the
register address at 2000(HEX) converted to 8192(DEC)+1 and the starting
address at 48193
Sample Program
Control with one GFDI-RM01N and one GFDO-RM01N
When the first point of DI has received a signal and is triggered, the first
point of DO will output a signal as it is connected
Read More About This Manual & Download PDF:
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>