MEANWELL LRS-35 Series 35W Single Output Switching Power Supply Owner’s Manual
- August 3, 2024
- MeanWell
Table of Contents
MEANWELL LRS-35 Series 35W Single Output Switching Power Supply
Product Usage Instructions
Installation
-
1. Ensure the power supply is disconnected from the power source.
- Select an appropriate mounting location with proper ventilation.
Connection
-
1. Connect the input terminals of the power supply to the AC power source within the specified voltage range.
- Connect the output terminals to the device requiring power, ensuring correct polarity.
Operation
-
1. After connections are secure, apply power to the power supply.
- Observe the LED indicators to ensure proper power output.
FAQ
- Q: What should I do if the power supply fails to turn on?
- A: Check the input connections and ensure the power supply is receiving power within the specified range. If the issue persists, contact customer support.
- Q: How can I troubleshoot excessive noise in the power output?
- A: Verify that all connections are secure and check for any interference sources near the power supply. If the noise persists, consider using additional filtering components.
Features
- Universal AC input / Full range
- Withstand 300VAC surge input for 5 second
- No load power consumption<0.2W
- Miniature size and 1U low profile
- High operating temperature up to 70°C
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- Compliance with IEC/BS EN/EN 60335-1 (PD3) and IEC/BS EN/EN61558-1, -2-16 for household appliances
- Operating altitude up to 5000 meters (Note.8)
- Withstand 5G vibration test
- High efficiency, long life, and high reliability
- LED indicator for power on
- Overvoltage category III
- 100% full load burn-in test
- 3 years warranty
Description
LRS-35 series is a 35W single-output enclosed type power supply with 30mm of
low profile design. Adopting the full range 85 ~ 264VAC input, the entire
series provides an output voltage line of 5V, 12V, 15V, 24V, 36 V, and 48V.
In addition to the high efficiency up to 89%, the design of the metallic mesh
case enhances the heat dissipation of LRS-35 and the whole series operates
from -30°C through 70°C under air convection without a fan.
Delivering an extremely low no-load power consumption (less than 0.2W), it
allows the end system to easily meet the worldwide energy requirement. LRS-35
has complete protection functions and 5G anti- vibration capability; it
complies with international safety regulations such as TUV BS EN/EN62368-1, BS
EN/EN60335-1, BS EN/EN61558-1/-2-16, UL62368-1 and GB 4943.1. LRS-35 series
serves as a high price-to-performance power supply solution for various
industrial applications.
Applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, types of equipment or apparatus
- Household appliances
GTIN CODE
- MW Search: https://www.meanwell.com/serviceGTIN.aspx
Model Encoding
35W Single Output Switching Power Supply
SPECIFICATION
MODEL| LRS-35-5| LRS-35-12| LRS-35-15| LRS-35-24|
LRS-35-36| LRS-35-48
---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 5V| 12V| 15V| 24V| 36V| 48V
RATED CURRENT| 7A| 3A| 2.4A| 1.5A| 1A| 0.8A
CURRENT RANGE| 0 ~ 7A| 0 ~ 3A| 0 ~ 2.4A| 0 ~ 1.5A| 0 ~ 1A| 0 ~ 0.8A
RATED POWER| 35W| 36W| 36W| 36W| 36W| 38.4W
RIPPLE & NOISE (max.) Note.2| 80mVp-p| 120mVp-p|
120mVp-p| 150mVp-p| 200mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE| 4.5 ~ 5.5V| 10.2 ~ 13.8V| 13.5 ~ 18V| 21.6 ~ 28.8V|
32.4 ~ 39.6V| 43.2 ~ 52.8V
VOLTAGE TOLERANCE Note.3| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%|
±1.0%
LINE REGULATION Note.4| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION Note.5| ±1.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1000ms, 30ms/230VAC 2000ms,30ms/115VAC at full
load
HOLD UP TIME (Typ.)| 30ms/230VAC 12ms/115VAC at full load
INPUT| VOLTAGE RANGE| 85 ~ 264VAC 120 ~ 373VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 82%| 86%| 86%| 88%| 88%| 89%
AC CURRENT (Typ.)| 0.7A/115VAC 0.42A/230VAC
INRUSH CURRENT (Typ.)| COLD START 45A/230VAC
LEAKAGE CURRENT| <0.75mA / 240VAC
PROTECTION| OVERLOAD| 110 ~ 150% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is
removed
OVERVOLTAGE| 5.75 ~ 6.9V| 13.8 ~ 16.2V| 18.75 ~ 21.75V| 28.8 ~ 33.6V|
41.4 ~ 48.6V| 55.2 ~ 64.8V
Protection type: Shut down o/p voltage, re-power on to recover
ENVIRONMENT| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along the X, Y, and
Z axes
OVERVOLTAGE CATEGORY| Ⅲ; According to BS EN/EN61558, BS EN/EN50178, BS
EN/EN60664-1, BS EN/EN62477-1; altitude up to 2000 meters
SAFETY & EMC
(Note 9)
| ****
SAFETY STANDARDS
| UL62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16,GB
4943.1, BSMI CNS15598-1, EAC TP TC 004,AS/NZS 60950.1(by CB),KC K60950-1(for
LRS-35-12/24 only), BIS IS13252(Part1): 2010/IEC 60950-1: 2005(NOTE 10)
approved
WITHSTAND VOLTAGE| I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS
EN/EN55014, BS EN/EN61000-3-2,-3, GB17625.1,GB/T 9254.1, BSMI CNS15936, EAC TP
TC 020,KC KN32,KN35(for LRS-35-12/24 only)
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS
EN/EN61000-6-2 (BS EN/EN50082-2), BS EN/EN55035,
heavy industry level, EAC TP TC 020, KC KN32, KN35(for LRS-35-12/24 only)
OTHERS
| MTBF| 3201.5K hrs min. Telcordia SR-332 (Bellcore); 655.5Khrs
min. MIL-HDBK-217F (25℃)
DIMENSION| 998230mm (LWH)
PACKING| 0.23Kg ; 60pcs/14.8Kg/0.88CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC
input, rated load, and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation, and load regulation.
4. Line regulation is measured from the low line to the high line at the rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to an increase in the setup time.
7. 5V when the load factor is 0~50%, the switching power is reduced by burst operation, which will cause ripple and ripple noise to go beyond the specifications.
8. The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m(6500ft).
9. The power supply is considered a component that will be installed into the final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on https://[www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)](http://www.meanwell.com/Upload/PDF/EMI_statement_en.pdf))
10. Some models may not have the BIS logo, please contact your MEAN WELL sales for more information.
※ Product Liability Disclaimer: For detailed information, please refer to https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx)
Block Diagram
Derating Curve
Static Characteristics
Mechanical Specification
Terminal Pin No. Assignment
Installation Manual
- Please refer to: http://www.meanwell.com/manual.html