MEANWELL EDR-75 Series 75W Single Output Industrial Din Rail Owner’s Manual
- June 1, 2024
- MeanWell
Table of Contents
MEANWELL EDR-75 Series 75W Single Output Industrial Din Rail
Specifications:
- Model: EDR-75 series
- Output Power: 75W
- Output Voltage: 12V, 24V, 48V
- Rated Current: 6.3A, 3.2A, 1.6A
- Protections: Short circuit, Overload, Over voltage, Over temperature
- Cooling: Free air convection
- Input Range: Universal AC input / Full range
- Warranty: 2 years
Product Usage Instructions
Installation:
- Ensure the DIN RAIL power supply is compatible with your industrial control system.
- Mount the power supply on DIN rail TS-35/7.5 or 15 following the installation guidelines.
- Connect the universal AC input to the power supply.
Operation:
- Switch on the power supply and ensure it is properly connected.
- Monitor the output voltage to ensure it meets your requirements.
- Check for any abnormal behavior such as overheating or overloading.
Maintenance:
- Regularly inspect the power supply for any physical damage.
- Clean the unit periodically to prevent dust buildup.
- Ensure proper ventilation for optimal cooling performance.
FAQ:
Q: What is the warranty period for the EDR-75 series DIN RAIL power
supply?
A: The warranty period for the EDR-75 series is 2 years.
Q: Can the power supply be used in semiconductor fabrication equipment?
A: Yes, the EDR-75 series DIN RAIL power supply is suitable for use in
semiconductor fabrication equipment.
Q: How do I adjust the output voltage of the power supply?
A: The voltage adjustment range for the EDR-75 series is specified in the
user manual. Follow the guidelines provided to adjust the voltage within the
specified range.
Features
- Universal AC input / Full range
- Protections: Short circuit / Overload / Over voltage/ Over temperature
- Cooling by free air convection
- Can be installed on DIN rail TS-35/7.5 or 15
- UL 508 (industrial control equipment) approved
- BS EN/EN61000-6-2(BS EN/EN50082-2) industrial immunity level
- 100% full load burn-in test
- 2 years warranty
Applications
- Industrial control system
- Semiconductor fabrication equipment
- Factory automation
- Electro-mechanical apparatus
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
EDR-75 is one economical slim 75W Din rail power supply series, adapt to be
installed on TS-35/7.5 or TS-35/15 mounting rails. The body is designed 32mm
in width, which allows space saving inside the cabinets. The entire series
adopts the full range AC input from 90 VAC to 264 VAC and conforms to BS
EN/EN61000-3-2, the norm the European Union regulates for harmonic current.
EDR-75 is designed with metal housing that enhances the unit’s power
dissipation. With working efficiency up to 88.5%, the entire series can
operate at the ambient temperature between -20°C and 60°C under air
convection. It is equipped with constant current mode for over-load
protection, fitting various inductive or capacitive applications. The complete
protection functions and relevant certificates for industrial control
apparatus (UL508, TUV BS EN/EN62368-1, and etc.) make EDR-75 a very
competitive power supply solution for industrial applications.
Model Encoding
SPECIFICATION
MODEL | EDR-75-12 | EDR-75-24 | EDR-75-48 |
---|
OUTPUT
| DC VOLTAGE| 12V| 24V| 48V
RATED CURRENT| 6.3A| 3.2A| 1.6A
CURRENT RANGE| 0 ~ 6.3A| 0 ~ 3.2A| 0 ~ 1.6A
RATED POWER| 75.6W| 76.8W| 76.8W
RIPPLE & NOISE (max.) **Note.2| 80mVp-p| 120mVp-p| 150mVp-p
VOLTAGE ADJ. RANGE| 12 ~ 14V| 24 ~ 28V| 48 ~ 55V
VOLTAGE TOLERANCE Note.3| ±2.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±1.0%
SETUP, RISE TIME| 1200ms, 60ms/230VAC 2000ms, 60ms/115VAC at
full load
HOLD UP TIME (Typ.)**| 60ms/230VAC 12ms/115VAC at full load
INPUT
| VOLTAGE RANGE Note.6| 90 ~ 264VAC 127 ~ 370VDC [DC
input operation possible by connecting AC/L(+), AC/N(-)]
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 85.5%| 87.5%| 88.5%
AC CURRENT (Typ.)| 1.45A/115VAC 0.9A/230VAC
INRUSH CURRENT (Typ.)| 20A/115VAC 35A/230VAC
LEAKAGE CURRENT| <1mA / 240VAC
PROTECTION
| ****
OVERLOAD
| 105 ~ 130% rated output power
Protection type : Constant current limiting, recovers automatically after
fault condition is removed
OVER VOLTAGE
| 14 ~ 17V| 29 ~ 33V| 56 ~ 65V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, re-power on to recover
ENVIRONMENT
| WORKING TEMP.| -20 ~ +60℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X,
Y, Z axes; Mounting: Compliance to IEC60068-2-6
SAFETY & EMC
(Note 4)
| SAFETY STANDARDS| UL508, TUV BS EN/EN62368-1, EAC TP TC 004, BSMI
CNS14336-1 approved;(meet BS EN/EN60204-1)
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class A, BS
EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438 Class A
EMC IMMUNITY
| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2),
heavy industry level, EAC TP TC 020
OTHERS
| MTBF| 2777.2K hrs min. Telcordia SR-332 (Bellcore) ; 506.6K hrs
min. MIL-HDBK-217F (25℃)
DIMENSION| 32125.2102mm (WHD)
PACKING| 0.51Kg; 28pcs/15.3Kg/1.22CUFT
NOTE
| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.
6. Derating may be needed under low input voltage. Please check the derating curve for more details.
7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Block Diagram
This series fits DIN rail TS35/7.5 or TS35/15.
For installation details, please refer to the Instruction manual.
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>