MEANWELL LRS-75 series AC DC Power Supply Instruction Manual
- August 4, 2024
- MeanWell
Table of Contents
MEANWELL LRS-75 series AC DC Power Supply
Features
- Universal AC input/ Full range
- Withstand 300VAC surge input for 5 second
- No load power consumption<0.3W
- Miniature size and 1 U low profile
- High operating temperature up to 70°C
- Protections: Short circuit/ Overload/ Over voltage
- Cooling by free air convection
- Compliance to IEC/BS EN/EN 60335-1 (PD3) and IEC/8S EN/EN61558-1, -2-16 for household appliances
- Operating altitude up to 5000 meters (Note. 7)
- Withstand 5G vibration test
- High efficiency, long life and high reliability
- LED indicator for power on
- Over voltage category III
- 100% full load burn-in test
- 3 years warranty
Description
LRS-75 series is a 75W single-output enclosed type power supply with 30mm of
low profile design. Adopting the full range 85~264VAC input, the entire series
provides an output voltage line of 5V, 12V, 15V, 24V, 36V and 48V.
In addition to the high efficiency up to 91.5%, the design of metallic mesh
case enhances the heat dissipation of LRS-75 that the whole series operates
from -30°C through 70°C under air convection without a fan.
Delivering an extremely low no load power consumption (less than 0.3W), it
allows the end system to easily meet the worldwide energy requirement. LRS-75
has the complete protection functions and 5G antivibration capability; it is
complied with the international safety regulations such as TUV BS
EN/EN62368-1, BS EN/EN60335-1,BS EN/EN61558-1/-2-16, UL62368-1 and GB 4943.1.
LRS-75 series serves as a high price-to-performance power supply solution for
various industrial applications.
Model Encoding
Applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, equipments or apparatus
- Household appliances
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION
MODEL| LRS-75-5| LRS-75-12| LRS-75-15| LRS-75-24|
LRS-75-36| LRS-75-48
---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 5V| 12V| 15V| 24V| 36V| 48V
RATED CURRENT| 14A| 6A| 5A| 32A| 2.1A| 1.6A
CURRENT RANGE| 0 ~14A| 0~6A| 0-5A| 0-3.2A| 0- 2 .1 A| 0-1.6A
RATED POWER| 70W| 72W| 75W| 76.8W| 75.6W| 76.8W
RIPPLE & NOISE (max.) Note .2| 100mVp-p| 120mVp-p| 120mVp-p|
150mVp-p| 200mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE| 4.5 -5,5V| 10.2-13.8V| 13.5- 18V| 21.6-28.8V| 32.4-
39.6V| 43.2- 52.8V
VOLTAGE TOLERANCE Note .3| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION Note.4| ±0.5%| ± 0.5%| ±0.5%| ± 0.5%| ± 0.5%| ±0.5%
LOAD REGULATION Note . 5| ± 1.0%| ±0.5%| ±0.5%| ± 0.5%| ±
0.5%| ±0.5%
SETUP, RISE TIME| 500ms, 30ms/230VAC 500ms,30ms/115VAC at full load
HOLD UP TIME (Typ.)| 60 ms/2 30VAC 12ms/115VAC atfull load
INPUT| VOLTAGE RANGE| 85 -264VAC 120- 373VDC
FREQUENCY RANGE| 47 -63Hz
EFFICIENCY (Typ.)| 86.5%| 89%| 89%| 90%| 91.5%| 91.5%
AC CURRENT (Typ.)| 1.4N115VAC 0.85N230VAC
INRUSH CURRENT (Typ.)| COLD START 65A/230VAC
LEAKAGE CURRENT| <0.75mA/ 240VAC
PROTECTION| OVER LOAD| 110 -150% rated output power
Protection type : Hiccup mode, reooversautomatically after fault condition is
removed
OVER VOLTAGE| 5.75- 6.75V| 13.8-16.2V| 18. 75 – 21.75V| 28.8 – 33.6V|
41.4-48.6V| 55.2-64.SV
Protection type : Shut down o/p voltage, re-power on to recover
ENVRONMENT| WORKING TEMP.| -30 – + 70’C (Refer to ‘Derating Curve’)
WORKING HUMIDITY| 20-90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 – +85’C, 10-95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/’C (0- 50°C)
VIBRATION| 10- 500Hz, 5G 10minJ1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY| Ill; Compliance to BS EN/EN61558, BS
EN/EN50178,BS EN/EN60664-1, BS EN/EN624 77-1; altitude up to 2000 meters
SAFETY & EMC (Note 8)| SAFETY STANDARDS| UL62368-1,
TUVBS ENIEN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16,GB4943.1,
BSMI CNS15598-1, EAC TPTC 004,AS/NZS 62368.1 (by CB),KC62368 -1,
BIS IS13252(Part1): 2010/IEC 60950-1: 2005(NOTE 9) approved
WITHSTAND VOLTAGE| UP-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
ISOLATION RESISTANCE| UP-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25’C/
70% RH
EMC EMISSION| Compliance to BS ENIEN55032 (CISPR32) Class B, BS
EN/EN55014, BS EN/EN61000-3-2,-3, GB17625.1,GB/T9254.1, BSMI CNS15936,
EACTPTC020,KCKSC9832, KSC9835
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8, 11, BS
EN/EN61000-6-2 (BS EN/EN50082-2), BS EN/EN55035,
heavy industry level,EAC TP TC 020, KC KSC 9832, KSC 9835
OTHERS| MTBF| 3334 .3 K hrs min. Teloordia SR-332 (Belloore) ;
667.2Khrs min. MIL-HDBK-217F (25’C)
DIMENSION| 99’97’30mm (L’W’Hl
PACKING| 0.25Kg ; 45pcs/ 12.25Kg/ 0. 77CUFT
NOTE|
-
All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25’C of ambient temperature.
-
Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
-
Tolerance : includes set vp tolerance, line regulation and load regulation.
-
Line regulation is measured from low line to high line at rated load.
-
Load regulation is measured from 0% to 100% rated load.
-
Length of set up time is measured at cold first start Turning Ot,t,OFF the power supply very quickly may lead to increase of the set up time.
-
The ambient temperature derating of 5’C/1000m Is needed for operating alt ltude greater than 2000m(6500ft).
-
The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm’360mm metal plate with 1 mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of Component power supplies.”
(as available on https://www.meanwell.com/Upload/PDF/EMI_statemenl_en.pdf) -
Some model may not have the BIS logo, please contact your MEAN WELL sales for more information.
- Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Block Diagram
Derating Curve
Static Characteristics
Mechanical Specification
Terminal Pin No. Assignment
Pin No. | Assignment | Pin No | Assignment |
---|---|---|---|
1 | AC/L | 4 | DC OUTPUT -V |
2 | AC/N | 5 | DC OUTPUT +V |
3 | FG |
Installation Manual
Please refer to : http://www.meanwell.com/manual.html