DEWERT OKIN PD22 Ac Dc Ad Apter Power Supply Instruction Manual
- July 30, 2024
- DEWERT OKIN
Table of Contents
- DEWERT OKIN PD22 Ac Dc Ad Apter Power Supply
- Installation Instructions
- Foreword
- General Information
- Safety notices
- Description
- Technical specifications
- Installation
- Operating notes
- Troubleshooting
- Maintenance and cleaning
- Disposal
- Instruction For Use
- FCC STATEMENT
- EU Declaration of Conformity
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DEWERT OKIN PD22 Ac Dc Ad Apter Power Supply
Installation Instructions
(Translation of the original installation instructions)
Foreword
Disclaimer and exclusion of liability
DewertOkin is not responsible for damage resulting from:
- failure to observe these instructions,
- changes made to this product that have not been approved by DewertOkin, or
- the use of replacement parts that have not been approved or manufactured by DewertOkin.
- We reserve the right to make unannounced technical changes in the course of our continual product improvement process!
Creation of a complete operating instruction manual for the entire end
product
These instructions are only intended to be used by the end-product
manufacturer. They should not be given to the operator of the end product. The
factual information contained within may be used as a basis when creating the
end-product manual. The warning and danger notices are best suited for use in
the end product’s manual. However, it is not sufficient to simply follow these
notices. You should also carry out an internal risk assessment for your end
product. This can then be used as the basis for the safety notices in your
manual. These installation instructions do not contain all the information
required to safely operate the end product. They only describe the
installation and operation of the product as partially completed machinery.
The instructions are intended for the technicians responsible for
manufacturing an end product and not for the operators of the end product.
General Information
About these installation instructions
These installation instructions must be followed closely in order to install
the PD12/PD13 POWER SUPPLY successfully and safely in the end product. These
instructions are not an operating manual for the end product. These
instructions will help you to minimize danger. They will also help you to
maximize the reliability and lifespan of the end product.
CAUTION
The notices in these instructions must be followed! Following the
guidelines during installation and connection procedures will help to
minimize:
- the risk of accident and injury, and
- damage to the PD22 or to the end product.
These installation instructions have been written with due care and attention. However, we cannot guarantee that the data, images and drawings are complete and correct nor do we accept any liability for the information contained therein, unless required by law.
Safety notices contained in the installation instructions and operating instructions for the entire machine
The manufacturer of the end product (the machine) is only permitted to operate the PD22,
- when the end product, is in compliance with all protective measures specified in the Machinery Directive 2006/42/EC, and
- when the manufacturer expressly declares the compliance of the end product.
The manufacturer of the end product must create a manual for the users of that product. The safety notices in the end-product manual must be written based on the end product’s risk assessment.
Conventions used
Notices which do not relate to safety are indicated in these instructions with
a symbol:
- Triangular notice symbol
Safety notice explanations
- WARNING indicates a hazardous situation which could result in death or serious injury.
- CAUTION indicates a hazardous situation that could result in minor or moderate injury.
- NOTICE is used to address practices which are not related to personal injury but may result in damage to the product or surroundings.
Safety notices
Proper and intended usage
The PD22 is intended for use:
- as a power supply unit for suitable DewertOkin drive systems,
CAUTION
Unfallgefahr
The PD22 should only be used for the applications described above. Any other
form of usage is not permitted and can lead to accidents or destruction of the
unit. Such non-approved applications will lead immediately to the expiration
of all guarantee and warranty claims on the part of the end-product
manufacturer against the manufacturer.
Improper usage
Be sure to follow the notices below concerning improper usage. You should
include them in your product manual in order to inform the users of your end
product.
The PD22 may not be used:
- in any environment where combustible or explosive gases or vapours (e.g., anaesthesiology)may be present,
- in the proximity of open fires or other heat sources (such as furnaces, ovens or direct sunlight),
- as a power source for toys or games,
- in any application that will be cleaned with an automated washing system,
- in a moist environment, or
- outdoors.
The PD22 can be used by children of 8 years and older, persons with reduced physical, sensory or mental capabilities, or persons with lack of experience or knowledge when they are supervised or instructed concerning the safe use of the device and when they understand the resulting risks. Do not allow children to play with this device. The cleaning and user maintenance must not be carried out by children without supervision.
Selection and qualification of personnel
The use of the PD22 in the end product may only be performed by qualified
personnel.
Rating plate of the PD22
- The rating plate shown is an example; the specifications for your PD22 may differ from this illustration.
- You should only use spare parts that have been manufactured or approved by DewertOkin.Only these parts will guarantee a sufficient level of safety.
AC/DC ADAPTER PD22 | Model name |
---|---|
CLASS 2 | Power Supply in compliance with UL1310 |
Match No.: PD22 | Part designation |
Model No.: ZB-H290020-T | Model number |
xxxxx | Model ID number |
Input: 100V – 240V ~ 50/60Hz | Input voltage and frequency |
1.6A | Current consumption |
Output: 29V 2A | Output voltage and max. output current during continuous |
operation
Prod. Date| Week/year
Serial No.| Serial number
EFFICIENCY LEVEL VI| Efficiency class
PD22
Description
The PD22 is an external power supply unit intended to supply power to drives and controllers from DewertOkin. The PD22 is connected to the main power by using a power cord. The PD22 has a non-referenced (unearthed) circuit which is separated from the supply voltage using doubled reinforced insulation.
PD22 components
- A PD22
- B Power cord
- C Connection cable for drive or control unit
Mains power connection for the PD22
WARNING Electric shock
Please follow these operating instructions carefully. You could be injured by
fire or electrical shock if you do not follow these assembly instructions.
Netzkabel
The appropriate power cord is included, depending on the regional version, in
the USA, continental Europe, the UK, or Australia.
CAUTION
Only use the proper power cord that is permitted in your country. Be sure to
use the correctly shaped plug, as shown in Figure 4.
- More information about the intended power supply cord can be found in the “Additional Information” section.
**Power cords of the PD22
**
- A PD22
- B Power cord (continental Europe version)
- C Power cord (USA version)
- D Power cord (Australian version)
- E Power cord (United Kingdom version)
Electrical Output
The outlet for the drive system is an LSP socket.
- A Connection for the LSP socket
Technical specifications
Technical specifications of the PD22
Mains power supply | 100 – 240V AC 50/60Hz |
---|---|
Output voltage (under no load) | max. 31V DC |
Output voltage/output power | Output: 29V 58W for continuous operations |
Output voltage/output current | 29V 2A for continuous operations |
Primary fuse | T3.15A |
Standby (no load) | ≤ 0.21W |
Degree of efficiency | ≥ 0,88 |
Efficiency class | EFFICIENCY LEVEL VI |
Mode of operations1) | Duty Cycle max 10%; max T ON 2min |
Protection class | II |
Protection degree | IP20 |
Length of power supply cable2) | < 2000mm |
Dimensions and weight
Length x width x height| approx. 120mm x 59mm x 37mm
Weight| approx. 230g
Ambient conditions for operation, storage, and transport
Transport/storage temperature| from -20 °C to +50 °C
from -4 °F to +122 °F
Operating temperature| from +10 °C to +40 °C
from +50 °F to +104 °F
Relative humidity| from 30% to 75%
Air pressure| from 800 hPa to 1060 hPa
Height| < 2000 m
- Mode of operation: Duty Cycle max 10%, max T ON 2 min. This means that after the unit is operated with 4A, it must then be paused for 18 minutes. The system can malfunction if this pause is not observed!
- Versions with a power cord shorter than 2 meters are only suitable for outlets near the floor.
Dimensionens of the PD22
Installation
Safety notices to observe during installation
Basic safety rules must be followed to ensure that the end product can be
continually operated safely. These rules must be observed while using the end
product and while installing the PD22 in the end product.
Avoiding electrical faults
The power supply cord is designed to be connected to an outlet near the floor.
Be sure to consider the length of the power cord when designing the dimensions
for your application to minimize the associated risks.
Installation procedure
Before installing and connecting the PD22, make sure that you are observing
all of the safety notices found in the “Safety notices to observe during
installation” section.
Installation the PD22
The PD22 is used as an accompanying device without any mounting or bolting
down required.
- As an accompanying device, you should be sure that any dangers presented by the cables are described in your end-product operating manual (refer to the “ Electrical connection” section.
CAUTION
The main power plug should be unplugged during the installation.
Electrical connection
CAUTION
Electric shock
Electrical components should be connected or disconnected only when the power
supply cord is unplugged.
- There is a delay after the supply voltage is applied before the device turns on. Wait at least 7 seconds before initial commissioning.
The use of a power cord
Warning Routing the electrical cables
When routing the cables, be sure that:
- the cables cannot get jammed,
- no mechanical load (such as pulling, pushing, or bending) will be put on the cables, and
- the cables cannot be damaged in any way.
Fasten all cables (especially the connecting cables) to the end product using sufficient kink-prevention methods. Be sure that the design of the end product prevents the connecting cables from coming into contact with the floor during transport.
Connecting the drive or drive control unit to the PD22
The drive system connection depends on the connection methods offered by the
drive or drive control unit:
- A Connection cable with an LSP plug
- B Connection socket
Use the appropriately labeled socket on the controller for the connection to the drive control unit.
CAUTION
You should only connect and disconnect the cables when they are completely
disconnected from any live current!
- Unplug the power plug from the outlet.
- Connect the drive/drive controller plug into the socket.
After plugging the power plug into the power outlet:
-
* There is a delay after the supply voltage is applied before the device turns on. Wait at least 7 seconds before initial commissioning.
Removing the PD22
- Unplug the power plug from the outlet.
- Pull out the drive cable or the drive controller cable from the PD22.
Operating notes
The factual information contained within may be used when you are creating the end-product manual. The installation instructions do not contain all the information required for the safe operation of the end product. They only describe the installation and operation of the PD22 as a partially assembled piece of machinery.
- When creating the operating instructions, remember that the installation instructions are intended for qualified specialists and are not for typical users of the end product.
General information
- Only drives and drive control units from DewertOkin should be connected to the PD22 since they have already been verified to work together.
Delayed start-up
After plugging the power plug into the power outlet:
- There is a delay after the supply voltage is applied before the device turns on. Wait at least 7 seconds before initial commissioning.
WARNING
Risk of accident Please follow these operating instructions carefully. You
could be injured by fire or electrical shock if you do not follow these
assembly instructions.
CAUTION
Only use the proper power cord that is permitted in your country. Be sure to
use the correctly shaped plug, as shown in Figure 4. Reducing the risk of
overheating with the thermal fuse
CAUTION
Risk of accident
The PD22 is equipped with a thermal fuse that triggers when the unit
overheats. If the temperature control has triggered, remove the PD22 from the
power supply, allow it to rest for 20 to 30 minutes, and try again. If the
unit still does not function, please contact your supplier or dealer.
Avoiding electrical risks
CAUTION
Electric shock
Make sure that all live (current-carrying) parts of the drive system and power
supply cannot be touched. In particular, be sure that unused power and control
unit connections are covered adequately.
Emergency shutoff
In an emergency, disconnect the PD22 from the power outlet so that the
connected drive or drive control unit shuts down. The power plug must always
be accessible during operations.
Avoiding cable damage
Be sure that your operating instructions inform the user about the possible
cable risks.
CAUTION
Risk of accident
The cables (particularly the mains cable and connecting cable) should not be
run over. To prevent injuries or damage to the PD22, no mechanical strain
should be placed on the cables.
Troubleshooting
This chapter describes troubleshooting methods for fixing problems. If you experience an error that is not listed in this table, please contact your supplier.
- Only qualified specialists who have received electrician training should carry out troubleshooting and repairs.
Problem | Possible cause | Solution |
---|---|---|
The drive or drive control unit is not functioning. | There is no mains supply | |
voltage. | Connect the mains power. | |
The drive or drive control unit is defective. | Please contact your supplier or |
sales agent.
Antriebe lassen sich plötzlich nicht mehr verfahren/bewegen.| The overheating
protection or system protection has been triggered.| Remove the overload
(change or remove the load).
Allow the system to rest for 20 to 30 minutes with the mains power unplugged.
If this does not resolve the problem, contact your supplier or distributor.
The unit’s fuse may have been triggered.| Please contact your supplier or
sales agent.
There is no mains supply voltage.| Connect the mains power.
A lead-in connection has been interrupted (mains power, auxiliary drive, or
handset).| Check the cables and reinsert them, if required.
Maintenance and cleaning
Maintenance
- The PD22 requires no special maintenance.
Cleaning
- Clean the PD22 as needed using a dry anti-static cloth.
NOTICE
- Be sure to unplug the PD22 power cord before you begin cleaning.
- Never clean the PD22 in an automated washing system or with a high-pressure cleaner. Do not allow fluids to penetrate the drive. Damage to the system could result.
- Do not use a cleanser that contains benzene, alcohol, or similar solvents.
- Be sure that you do not damage the connecting cables during the cleaning.
Disposal
Packaging material
The packaging material should be sorted into recyclable components and then
disposed of by the appropriate national environmental regulations (in Germany
according to the recycling law KrWG from 01.06.2012; internationally according
to the EU Directive 2008/98/EC (Waste Framework Directive WFD as of
12.12.2008)).
PD22 components
The PD22 consists of electronic components, cables, and metal and plastic
parts. You should observe all corresponding national and regional
environmental regulations when disposing of the PD22. The disposal of the end
product is regulated in Germany by Elektro-G, internationally by the EU
Directive 2012/19/EC (WEEE), or by any applicable national laws and
regulations.
Additional information
PD22
Power cable recommended for use in Europe:
Power cable (refer to IEC/EN 61558-1)
Flexible cord type| Conductor size| Number of conductors|
Cord length
| Minimum| Maximum
H05VV-F, H05VVH2-F, H05RR-F| 0,75 mm²| 2| 2 m| 4 m
Power cable recommended for use in the USA and Canada:
Power cable (refer to UL 1310)
Flexible cord type| Conductor size| Number of conductors|
Cord length
| Minimum| Maximum
SP-2, SPE-2, SPT-2, SV, SVE, SVT| 18 AWG| 2| 0.91 m (3 feet)| 3 m (10 feet)
S, SE, SO, SP-3, SPT-3, ST, STO, SJ, SJE, SJO, SJT, SJTO| 18 AWG| 2| 0.91 m (3
feet)| Not specified
The PD22 should not be disposed of with normal household waste!
Instruction For Use
Class 2 Power Unit
Version 1.0
INTENDED USE
The switching Power Supply (SPS) is intended to supply with safe extra low
voltage. The SPS is an appliance inlet type (or directly plugged into a socket
outlet) while the device to be supplied is connected with a cord and plug from
the SPS. Observe and follow the instructions and cautions as follows.
Otherwise, SPS damage and/or serious injury may occur, save the instructions
for further reference.
IMPORTANT SAFETY INSTRUCTIONS – SAVE THESE INSTRUCTIONS.
DANGER – TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, CAREFULLY FOLLOW THESE INSTRUCTIONS.
Connections:
- Only connect with a supply equal to the voltage shown on the SPS;
- Only connect with a load that does not exceed the rated load of the SPS;
- Only use the SPS in conjunction, not in the U.S.A., use an attachment plug adapter of the proper configuration for the power outlet.
Ambient Conditions:
- Operating temperature: 0°C ~ 30°C
- Operating relative humidity: 20% ~ 95%
- Storage temperature: 0°C ~ 60°C
- Storage relative humidity: 20% ~ 95%
- Do not operate near fire or in high temperature ambient;
- Do not use this SPS in a dusty ambient;
- Only operate the SPS in dry rooms indoors;
- Do not expose to water or other conductive liquid electric shock hazard.
CAUTION: Risk of Electric Shock Dry location only. See instruction manual for use in countries other than the U.S.A
MAINTENANCE
- Check the power supply cord and output cord for damage before use;
- Check the enclosure for cracks or other damage before use;
- ATTENTION: Do not operate the SPS if the connection cords or the enclosure are damaged. A damaged SPS cannot be repaired. Disable the damaged SPS in an obvious way. So that it won’t represent a hazard to others. Please dispose off a damaged SPS according to the local regulations;
- The SPS may be cleaned with a damp towel, but may never get in direct contact with water. After cleaning please make sure that the SPS is dried completely;
- Do not use any organic solvents (petrol, alcohol, etc.) for cleaning the SPS. The case of the SPS may be damaged and explosive vapors may develop. Do not use any sharp edged objects for cleaning;
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by person responsible for their safety;
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard;
- Fuse only replaceable by qualified professional.
FCC STATEMENT
NOTE
This Class B digital apparatus complies with Canadian ICES-003. This device
complies with part 15 of the FCC rules. Operation is subject to the follow two
conditions: (1) this device may not cause interference, and (2) this device
must accept any interference, including interference that may cause undesired
operation of the device. This equipment has been tested and found to comply
with the limits for Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates
uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
EU Declaration of Conformity
- In compliance with Appendix IV of the EMC-Directive 2014/30/EU
- In compliance with Appendix IV of the LVD-Directive 2014/35/EU
- In compliance with Appendix VI of the EU RoHS Directive 2011/65/EU
The manufacturer:
- declares that the following product
AC/DC ADAPTER PD221) POWER SUPPLY PD221)
meets the requirements of the following EU directives: Electromagnetic Compatibility Directive 2014/30/EU Low Voltage Directive 2014/35/EU RoHS Directive 2011/65/EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment. Applied standards:
- EN 60335-1:2012/A13:2017
- EN 55014-1:2006/A1:2009/A2:2011
- EN 55014-2:1997/A1:2001/A2:2008
- EN 61000-3-2:2014
- EN 61000-3-3:2013
- EN 61558-1:2005+A1:2009
- EN 61558-2-16:2009+A1:2013
- EN 62233:2008
This declaration of conformity is no longer valid if constructional changes are made that significantly change the drive system (i.e., which influences the technical specifications found in the instructions or the intended use)!
- with DewertOkin components
- DewertOkin GmbH Weststraße 1 32278 Kirchlengern, Germany
- Tel: +49 (0)5223/979-0
- Fax: +49 (0)5223/75182
- http://www.dewertokin.de
- Info@dewertokin.de