LUTRON RRST-H Sunnata RF Hybrid Keypad Dimmer Instruction Manual

June 3, 2024
Lutron

P/N 044387 REV A

Dimmer

Please read before installing.

Sunnata RF Hybrid Keypad
RRST-H (single-pole only)
120 V~ 50/60 Hz

150 W
LED/CFL

450 W
Inc./Hal./ELV

350 VA
MLV

Help

RA3 Support Center

For additional support with installing, programming, and troubleshooting

   LUTRON RRST-H Sunnata RF Hybrid Keypad Dimmer QR code
1

lutron.com/RA3support

Find the right LED

 

lutron.com/LEDfinder

Use our mobile friendly self-paced installation tool:
www.lutron.com/wiringwizard

Find more product information:
www.lutron.com/support
– Videos
– Frequently Asked Questions

Call us:
U.S.A.|Canada|Caribbean
1.844.LUTRON1 (588.7661) (24/7)

Mexico

  • 1.888.235.2910

Others

  • 1.610.282.3800

www.lutron.com/support

Limited Warranty:
www.lutron.com/TechnicalDocumentLibrary/Warranty.pdf

For FCC/IC information:
Please visit: www.lutron.com/fcc-ic

The Lutron logo, Lutron, Sunnata, Claro, Clear Connect, FASS, Pico, RadioRA, and RadioRA 3 are trademarks or registered trademarks of Lutron Electronics Co., Inc. in the US and/or other countries.

All other product names, logos, and brands are property of their respective owners.

©2022 Lutron Electronics Co., Inc.

1 Turn power OFF at circuit breaker

WARNING: ELECTRIC SHOCK HAZARD.
May result in Serious Injury or Death. Turn off power at circuit breaker or fuse before installing.

2 Load types and derating

* Maximum Allowable Load


Single Gang

|

End of Gang

|

Middle of Gang

LUTRON RRST-H Sunnata RF Hybrid Keypad Dimmer Table 1
See Section 7 on page 2 of this guide for phase-select instructions.

Note: For dimming MLV fixtures, the maximum bulb wattage is typically 70%-85% of the transformer’s VA rating. For actual transformer efficiency, contact the manufacturer. The total VA rating of the transformer(s) shall not exceed the VA rating of the dimmer.

IMPORTANT

  1. CAUTION: Use only with permanently installed fixtures with dimmable screw-in LED, dimmable self-ballasted compact fluorescent, halogen, or incandescent bulbs. Use only to control the primary side of permanently installed transformer supplied low-voltage lighting, or in combination with incandescent bulbs. To reduce the risk of overheating and possible damage to other equipment DO NOT use to control receptacles, fluorescent lighting fixtures, non-ballasted or externally ballasted compact fluorescent bulbs, motor operated appliances or transformer supplied appliances.
  2. Neutral is required for all load types.
  3. When no “grounding means” exist within the wallbox, the NEC® 2015, Article 404.9 allows a dimmer without a grounding connection to be installed as a replacement, as long as a plastic, noncombustible wallplate is used. For this type of installation, twist a wire connector onto the green ground wire or remove the green ground wire on the dimmer and use an appropriate wallplate such as Claro or satin finish series wallplates by Lutron.
  4. Protect the keypad from dust and dirt when painting or spackling the wall.
  5. It is normal for the keypads to feel warm to the touch during operation.
  6. Codes: Install in accordance with all local and national electrical codes. Type 1 action independently mounted operating control. Pollution degree 2, Impulse voltage 4 kV.
  7. Environment: Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C), 0 to 90% humidity, non-condensing. Indoor use only.
  8. Wallplates: Lutron Claro and satin finish wallplates are strongly recommended for best color match and clean aesthetic appearance.
  9. Cleaning: For disinfecting keypad, please refer to www.lutron.com/cleaning. See RA3 Support Center link in Help Section.
  10. Wallboxes: All keypads require a U.S. wallbox. 3in (89 mm) deep recommended, 2 in (63.5 mm) deep minimum.
  11. RF Device Placement: Keypads communicate with the system through Clear Connect–Type X Radio Frequency (RF) and must be located within 75 ft (22.8 m) of a centrally located RadioRA 3 processor. Each Sunnata keypad should have at least two other non-battery powered Clear Connect–Type X devices within 25 ft (7.6 m). Clear Connect–Type X devices include the RadioRA 3 processor, Sunnata dimmers, Sunnata switches, and other Sunnata keypads. Accessory dimmers/switches are not Clear Connect–Type X devices. System devices operate on a frequency of 2.4 GHz.
  12. System Programming: Programming and activation (addressing) must be accomplished through the RadioRA 3 software.
  13. Hybrid keypads are single pole only. For help on adding keypads to 3-way / 4-way lighting circuits, refer to App Note #232 (048232) on www.lutron.com
3 Wire the control

LUTRON RRST-H Sunnata RF Hybrid Keypad Dimmer A05

4 Mount the wallplate adapter

LUTRON RRST-H Sunnata RF Hybrid Keypad Dimmer A06

5 Mount the keypad and attach the wallplate

LUTRON RRST-H Sunnata RF Hybrid Keypad Dimmer A07

6 Turn power ON at circuit breaker
7 System setup

This keypad must be used in a RadioRA 3 system with a processor for control of dimmers, switches, and shades. Use the RadioRA 3 programming software to setup the system (training is required to access the software).

8 Operation

LUTRON RRST-H Sunnata RF Hybrid Keypad Dimmer A09

1. Keypad Buttons
• Press to activate desired levels of lighting or positions of shades /draperies
• The default operation depends on the button configuration (model number):
– 2B: Top button is ON, bottom button is OFF
– 3RL: Top button is ON, the next button is 50%, the next button is OFF, the buttons at the bottom raise and lower the lights
– 4B: Top button is ON, the next button is 50%, the next two buttons are OFF

2. Status LEDs
• Show which button has been activated

FASS
(Front Accessible Service Switch) Pull tab out to change the room’s light bulb.

Return to factory settings

Note: Returning a keypad to its factory settings will remove the keypad from the system and erase all programming.
Step 1: Triple tap any button on the keypad (except raise/lower). DO NOT release after third tap.
Step 2: Keep the button pressed on the third tap until all the status LEDs start to flash slowly (approximately 3 seconds).
Step 3: Immediately release the button and triple tap the button again. The status LEDs on the keypad will flash quickly. The keypad has now been returned to its factory settings.

LUTRON RRST-H Sunnata RF Hybrid Keypad Dimmer A10

FCC/IC/IFT Information

This device complies with part 15 of the FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference that may cause undesired operation. Modifications not expressly approved by Lutron Electronics Co., Inc. could void the user’s authority to operate this equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna
  • Increase the separation between the equipment and receiver
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
  • Consult the dealer or an experienced radio/TV technician for help.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. The user should avoid prolonged exposure within 7.9 in (20 cm) of the antenna, which may exceed FCC radio frequency exposure limits.

This Class B digital apparatus complies with Canadian ICES-003.

2B                                3RL                             4B

  1. LED (A)
  2. LED (B)
  3. FASS (Front Accessible Service Switch)
Setup
Setup for use WITHOUT a system

Note: These are temporary settings to help verify the installation. They will be over-written by the system software during system programming.

Phase Selection

  1. Pull out the FASS (Front Acessible Service Switch).
  2. Press and hold BOTH button A AND button B as you push the FASS back in.
  3. Continue holding both buttons until the LED A and B start flashing (takes about 5 seconds), then release the buttons.
  4. Push button A to select forward-phase (LED A will blink slowly).
  5. Push button B to select reverse phase (LED B will blink slowly).
  6. To save and exit, press and hold BOTH button A AND button B until the LEDs stop blinking (takes about 5 seconds).

High-End Trim

  1. Pull out the FASS (Front Accessible Service Switch).
  2. Press and hold button A as you push the FASS back in.
  3. Continue holding button A until LED A starts flashing (takes about 5 seconds), then release the button.
  4. Push button A to raise the high-end.
  5. Push button B to lower the high-end.
  6. To save and exit, press and hold BOTH button A AND button B until the LEDs stop blinking (takes about 5 seconds).

Low-End Trim

  1. Pull out the FASS (Front Accessible Service Switch).
  2. Press and hold button B as you push the FASS back in.
  3. Continue holding button B until LED B starts flashing (takes about 5 seconds), then release the button.
  4. Push button A to raise the low-end.
  5. Push button B to lower the low-end.
  6. To save and exit, press and hold BOTH button A AND button B until the LEDs stop blinking (takes about 5 seconds).
Setup for use WITH a system

NOTE: If setting up as part of system, phase settings and low-end trim levels made on the dimmer will be over-written by the system software.

For use in a RadioRA 3 system, please refer to the Getting Started Guide: www.lutron.com/RA3support

Troubleshooting
Symptom Cause Action
LED A blinks once per second, LED B is off (or dimly lit) Hybrid
keypad is detecting a wiring error Check the wiring against Step 3 of the

instructions. Verify that the black and red wires are not swapped.
LED A and LED B flashing alternately, once per second| Hybrid keypad is seeing higher voltage than expected|

  1. Change between forward-phase and reverse-phase. Refer to the instructions under Setup for phase selection.
  2. Ensure that the input voltage to the device is less than 130 V~.

LED A flashes once per second, LED B stays on| Hybrid keypad is detecting a problem with the circuit|

  1. Verify that the bulb is dimmable. Test with an incandescent/halogen bulb. Check compatibilty on www.lutron.com/ledfinder
  2. Check the wiring against Step 3 of the instructions. Verify that the black and white wires are not swapped.
  3. Test on another lighting circuit.

LED A and LED B flashing together, once per second| Hybrid keypad has exceeded its rated temperature|

  1. Ensure load is within ratings noted in Step 2 of the instructions. Note deratings for multi-gang applications.
  2. Ensure ambient temperature is less than 104 °F ( 40 °C).

LED A stays on, LED B blinks once a second| Hybrid keypad is seeing higher current than expected|

  1. Check the wiring against Step 3 of the instructions. Verify that the white and red wires are not swapped.
  2. Check for short circuits to neutral or ground in all wiring locations, including at the load.
  3. Replace the load(s) to check if it failed as a short.
  4. Change between forward-phase and reverse-phase. Refer to the instructions under Setup for phase selection.
  5. Check if bulb is compatible on www.lutron.com/ledfinder. Change to compatible bulb.

LED lights do not operate well or they flicker/ buzz| The phase is not set to the correct setting for your load type| Change between forward-phase and reverse-phase. Refer to the instructions under Setup for phase selection.
The low-end is not adjusted| Refer to the instructions under Setup for adjusting low-end trim.
The bulb is not compatible with your Lutron dimmer| Find a compatible bulb by visiting Lutron’s LED compatibility tool at www.lutron.com/ledfinder
LED lights do not dim low enough| The low-end is not adjusted| Refer to the instructions under Setup for adjusting low-end trim.
Status LEDs on the keypad don’t light up when buttons on it are pressed| Power not present at keypad| Circuit breaker OFF. Turn ON breaker.
Incorrect wiring| Check the wiring against Step 3 of the instructions.
A specific dimmer, switch or shade / drapery is not controlled when a button is pressed on the keypad| The dimmer, switch or shade / drapery is not assigned to the keypad| Refer to the programming software and ensure the device is assigned to the keypad. Perform a transfer and make sure it is successful.
Failure has occurred on the bulb(s) controlled by the dimmer/switch| Replace the bulb(s).
There is no power to the dimmer, switch, shade / drapery| Ensure that the device is powered and that the FASS switch is pushed in.
Devices are out of range| Ensure this device is placed within 25 ft (7.6 m) of two additional compatible wireless devices.
Dimmer, switch or shade / drapery does not go to the desired level or position when a button on the keypad is pressed| The button was not programmed correctly| Refer to the programming software and ensure the device is assigned to the keypad. Perform a transfer and make sure it is successful.
Devices are out of range| Ensure this device is placed within 25 ft (7.6 m) of two additional compatible wireless devices, such as RadioRA 3 Sunnata products and the RadioRA 3 processor.
All status LEDs on the keypad flash when any button is pressed| The keypad is in the Factory Settings mode and has not been configured to work in a system| Refer to the programming software and ensure the device is assigned to that keypad. Perform a transfer and make sure it is successful.
Lights do not respond to a Hybrid Keyboard button press or do not go to desired levels| Power not present at keypad|

  1. Circuit breaker tripped or OFF. Reset or turn ON circuit breaker.
  2. Verify that the wire connections did not come loose.

FASS switch is pulled out| Push FASS switch in.
Bulbs burned out or not installed| Replace or install bulbs.
Non-dimmable lamps| If non-dimmable lamps are being used, replace with dimmable lamps.
Out of RF range| Reposition to be within 30 ft (9 m) of an RF signal repeater.
Improper programming| Program according to the system Setup Guide.
Attached lights turn ON when top Hybrid Keypad button is pressed, then turn OFF| Load is less than minimum load requirement| Make sure the connected load meets the appropriate minimum load requirement for the control. See Step 2, Load types and derating.
Improper programming| Program according to the system Setup Guide.
All LEDs on the Hybrid Keypad flash when any button is pressed| The Hybrid Keypad is in Factory Settings mode and has not been configured to work in a system| Follow the steps in the system Setup Guide to program the Hybrid Keypad.
Wallplate is warm| Solid-state control dissipation| Solid-state Hybrid Keypads internally dissipate about 2% of the total connected load. It is normal for Hybrid Keypads to feel warm to the touch during operation.

For additional Troubleshooting, please visitwww.lutron.com/RA3support