LUTRON Ivalo Finire 3 Inch Retrofit Lighting Instruction Manual
- October 30, 2023
- Lutron
Table of Contents
LUTRON Ivalo Finire 3 Inch Retrofit Lighting
Product Information
The LED Module / Driver Kit is a retrofit kit designed to replace traditional lighting fixtures with energy-efficient LED lighting technology. The kit includes a reflector, light module, and Lutron LED driver. The LED driver is compatible with rough-in housing and adjustable armature fixtures. The kit is designed to be field-replaceable, allowing for easy installation and maintenance. The LED retrofit kit requires knowledge of luminaire electrical systems. It is important to turn off power before installing the kit. If not qualified, do not attempt installation. Contact a qualified electrician.
Product Usage Instructions
- Turn off the power.
- If installing an LED module/driver kit for a rough-in housing,
- start at Step 5: Field replace the LED driver
- Remove trim.
- For Trimmed fixtures: Pull-on flange of the trim until the trim is free (Figure 1).
- For Trimless fixtures: Press the glass upwards and pull down on the aperture of the trim until it is released from the mud ring.
- Field replace reflector (Figure 2).
- Hold the reflector by the edges. Twist counter-clockwise to unlock from the light module.
- Carefully remove the reflector.
- Note: Do NOT touch the reflective surface of reflector. Install a new reflector. Twist clockwise to lock into light module.
- Field replace light module (Figure 3).
- Match LED module number on the module grab plate (Figure 3) to housing label, located inside the fixture housing.
- Grab the module at the support and pull light module out of the module support bracket.
- Disconnect the module from the connector. See Figure 4 for the connector diagram.
- Connect the new module to the connector.
- Secure new module into module support bracket. Make sure all wiring is clear from the support bracket, light module, and reflector.
- Field replace LED driver (Figure 5).
- Refer to the LED driver replacement guide provided with the LED driver.
- Confirm trim, reflector, and light module are removed as per steps 2, 3, and 4.
- For Downlight fixtures or Adjustable fixtures with the tilt-lock screw.
- Replace the light module, reflector, and trim.
- Restore power.
Note: To prevent damage or abrasions, do not expose wiring to edges of sheet metal or other sharp objects. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. If experiencing any issues with the LED retrofit kit, refer to the Troubleshooting section in the user manual.
Field Replace Components
WARNING: Risk of Fire or Electric Shock. May result in serious injury or
death. LED retrofit kit installation requires knowledge of luminaire
electrical systems. If not qualified, do not attempt installation. Contact a
qualified electrician.
NOTICE: Property Damage. To prevent damage or abrasions, do not expose
wiring to the edges of sheet metal or other sharp objects.
Note: Do not make or alter any open holes in an enclosure of wiring or
electrical components during kit installation.
- Turn off power.
- Note: If installing an LED module/driver kit for a rough-in housing, start at “Step 5: Field replace LED driver”
- Remove trim.
- a. For Trimmed fixtures: Pull on flange of trim until the trim is free.
- b. For Trimless fixtures: Press glass upwards and pull down on aperture of the trim until it is released from the mud ring.
- Field replace reflector.
- a. Hold reflector by edges. Twist counter-clockwise to unlock from the light module.
- b. Carefully remove reflector.
- Note: Do NOT touch reflective surface of reflector.
- c. Install new reflector. Twist clockwise to lock into light module.
- Field replace light module.
- a. Match LED module number on module grab plate (Figure 3) to housing label, located inside the fixture housing.
- b. Grab the module at the support and pull light module out of the module support bracket.
- c. Disconnect module from connector. See Figure 4 for connector diagram.
- d. Connect new module to the connector.
- e. Secure new module into module support bracket. Make sure all wiring is clear from the support bracket, light module, and reflector.
- Field replace LED driver.
- Note: Refer to LED driver replacement guide provided with the LED driver.
- a. Confirm trim, reflector, and light module are removed as per steps 2, 3, and 4.
- b. For Downlight fixtures or Adjustable fixtures with the tilt-lock screw installed, remove the support bracket locking screw and rotate the bracket away from the driver to access the driver compartment.
- Note: For Rough-In Housing: This step can be skipped since the housing is already set to this position.
- c. Remove the wing nut(s) on the LED driver support bracket.
- d. Remove the LED driver from the support bracket and pull out of the aperture. Disconnect the wires from the existing LED driver.
- Note: For Rough-In Housing: If installing an LED module/driver kit for rough-in housing this step can be skipped as there is no LED driver installed.
- e. Transfer the wing nut(s) to the studs on the new LED driver and connect the wires to the new LED driver.
- Note: For Rough-In Housing: Use the provided quick connectors
- f. Insert the new LED driver into the aperture and install it into the support bracket.
- g. Install the wing nut(s) on the support bracket.
- Replace the light module, reflector, and trim.
- Restore power
LED Recessed Lighting
Fixture Diagram
Troubleshooting
Symptoms | Solution(s) |
---|---|
The light is flickering, flashing, dropping out, or does not turn on. | • Check |
all fixture wires and connections to ensure that they are properly connected.
• Verify that controls and drivers are connected properly.
• Verify that a compatible control is being used to control the driver. For a list of compatible controls and control ratings, visit www.lutron.com/finire
• Ensure that 120 / 277 V~ power is present and properly connected to the LED driver.
Note: F1 model (2-wire) is 120 V~ only.
• Adjust low-end trim on the control.
• Verify that ambient temperature is within the specified range.
• Non-IC fixtures are intended for free-air applications. Do not confine Non- IC fixtures with insulation or building materials.
LED exhibits a flash or steppy dimming on first use.| • Drivers will “learn”
the LED load on the first startup. This is a one-time event for a particular
driver/ LED combination. Running the load at full output for 20 seconds will
complete “learning.”
LED does not dim.| • Verify that the control/driver wiring is wired properly.
The trim does not fit.| • Verify that an adjustable trim is being used with an
adjustable housing.
If using a downlight trim with an Adjustable fixture, verify that the tilt is 20° or less.
• Trimless fixtures: Ensure that the inside of the mud ring is free of excess plaster.
• Trimmed fixtures: Ensure ceiling material thickness matches trim specification. Thick ceiling trim brackets are required for ceiling material greater than 0.625 in (16 mm).
- If a Lutron system is installed on-site and assistance is needed with programming or performance issues, please contact Lutron Customer Assistance at 1.844.LUTRON1 or lightingsupport@lutron.com.
FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause interference, and
This device must accept any interference, including interference that may
cause undesired operation. Modifications not expressly approved by Lutron
Electronics Co., Inc. could void the user’s authority to operate this
equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and receiver
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
- Consult the dealer or an experienced radio/TV technician for help CAN ICES-005 (B) / NMB-005 (B)
Circuit Diagrams for Dimming
- For a list of compatible controls and control ratings, visit www.lutron.com/finire or contact the LED Control Center of Excellence at 1.877.DIM.LED8 or lightingsupport@lutron.com.
Retrofit Kit Part Number| Compatible Housing|
---|---|---
F3y-LMXX-xxzzF1|
Fab3cxddeeffgghhii
|
F3y-LMXX-xxzzEU
F3y-LMXX-xxzzH0
F3y-LMHO-xxzzF1
F3y-LMHO-xxzzEU
F3y-LMHO-xxzzH0
F3y-LMNS-xxzzF1
F3y-LMNS-xxzzEU
F3y-LMNS-xxzzH0
F3y-LMHP-xxzzF1|
Fab3cNddeeffgghhii
|
F3y-LMHP-xxzzEU
F3y-LMHP-xxzzH1
Retrofit Kit Part Number – Warm Dim| Compatible Housing|
F3y-LMWXxxzzF1|
Fab3cxWyeeffgghhii
|
F3y-LMWX-xxzzEU
F3y-LMWX-xxzzH0
F3N-LMWH-xxzzF1|
Fab3cNWyeeffgghhii
|
F3N-LMWH-xxzzEU
F3N-LMWH-xxzzH1
|
Retrofit Kit Part Number Guide| Compatible Housing Guide|
y = IC or Non-IC housing| a = Trim type (A for Adjustible, D for
Downlight)|
xx = Color Temperature| b = Flange (T for Trim, Z for Trimless)|
zz = Beam Angle| c = Shape (R for Round, S for Square)|
| d = Housing Type (I for Insulation Contact, N for Non Insulation)|
| ee = LED Type|
| ff = Color Temperature|
| gg = Beam Spread|
| hh = Hanging Method|
| ii = Ceiling Thickness|
| y = Type of Warm Dim LED (X – Standard H – High Plus)|
CONTACT
- Lutron Electronics Co., Inc.
- 7200 Suter Road, Coopersburg, PA 18036
- Telephone 610.282.7472 Fax 610.282.7600
- lightingsupport@lutron.com.
- For limited 10-year warranty details, see
- www.lutron.com/TechnicalDocumentLibrary/3683454.pdf
- Specification subject to change without notice
The Lutron logo, Lutron, EcoSystem, Finiré Lutron Ivalo Collection, Hi-lume,
IVALO, IVALO Lighting (registered in the U.S. only), and Soft-on Fade-to-Black
are trademarks or registered trademarks of Lutron Electronics Co., Inc. in the
US and/or other countries.
©2022 – 2023 Lutron Electronics Co., Inc.
www.lutron.com/ivalo. 610.282.7472
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>