LUTRON RCL-153PNL LED Plus Dimmer Installation Guide
- May 15, 2024
- Lutron
Table of Contents
RCL-153PNL LED Plus Dimmer
Installation Guide
How-to videos
LED + Dimmer
Install with confidence
Use included diagrams or visit our website for step-by-step instructions.
120 V~ 60 Hz
Find the right LED
RCL-153PNL
150 W | 600 W * |
---|---|
LED / CFL | Incand. / Halogen |
Please read before installing
Ganging and Derating
Derating is necessary if mounting two or more devices side by side (see chart
for new wattage rating).
Note: Derating not necessary for LED / CFL loads.
Important Notes
- CAUTION: Use only with permanently installed fixtures with dimmable screw-in compact fluorescent, dimmable screw-in LED, halogen, or incandescent lamps. To avoid overheating and possible damage to other equipment, do not use to control receptacles, motor-driven appliances, or transformer-supplied appliances.
- Install in accordance with all national and local electrical codes.
- When no “grounding means” exists in wallbox, the National Electrical Code (NECR) allows a control to be installed as a replacement when a plastic faceplate with plastic fasteners is used, or the circuit is protected by a ground fault circuit interrupter (GFCI). Lutron wallplates meet this requirement. Cap or remove green wire before screwing control into wallbox.
- Protect the dimmer from dust and dirt when painting or spackling the wall.
- It is normal for the dimmer to feel warm to the touch during operation.
- Clean the dimmer with a soft damp cloth only. Do not use any chemical cleaners.
- For indoor use only.
INSTALL WITH CONFIDENCE
WARNING: ELECTRIC SHOCK AZARD. May result in serious injury or death.
Turn off power at circuit breaker or fuse before installing.
Before installing remove the rotary knob and the light ring.
Single Pole
For lights switched from one location: NOTE: Black and solid red wire on the
dimmer are interchangeable.
3-Way
For lights switched from two locations:
IMPORTANT: Mark or tag the common wire (connected to the different
colored screw) before removing the old switch. NOTE: Only one dimmer can be used in a
3-way circuit.
AFTER INSTALLATION: Adjust low-end dimming range for LEDs and CFLs
- Push shaft to turn lights on and rotate counter-clockwise to adjust the low-end.
- Move adjustment lever up or down to adjust the low-end dimming range.
- Push shaft to turn lights OFF and ON to verify proper operation.
NOTE: It may be helpful to attach the knob for this step.
Mount Dimmer and Restore Power
1. Attach faceplate| 2. Note the UP arrow
3. Push the light ring on| 4. Push the knob on firmly
Limited Warranty: www.lutron.com/warranty or
call 1.844.LUTRON1 (+1.888.235.2910 in Mexico) for a printed copy.
Lutron and LED+ are trademarks or registered trademarks of Lutron Electronics
Co., Inc., in the U.S. and other countries.
The YouTube icon is a trademark of Google LLC. ©2020–2023 Lutron Electronics
Co., Inc. For Troubleshooting, please visit
www.lutron.com/support
www.lutron.com/CLregistration
Assistance : 1.844.LUTRON1 (É.-U./ Canada
1.888.235.2910 Mexique
References
- How to Install a Dimmer Switch | Dimmer Switch Wiring | Lutron Web Tools
- LED Compatibility Tool | Lutron
- lutron.com/CLregistration
- Lutron Support Center | Lutron
- Product Selection Page
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>