LUTRON RadioRA 3 Fan Control Installation Guide

June 1, 2024
Lutron

LUTRON RadioRA 3 Fan Control

Specifications

  • Model: RRST-ANF
  • Input Voltage: 120 V~
  • Frequency: 50 / 60 Hz
  • Current: 1.5 A
  • Compatible with AC fan only

Product Usage Instructions

Install the Fan

  • Follow the manufacturer’s instructions to properly install the fan and ensure it operates correctly.

Set the Fan Speed

  • Use the pull chains to set the fan to the highest speed before installation.

Turn Power Off

  • Before installing, turn off the power at the circuit breaker to avoid any electrical hazards.

Remove Existing Switch

  • Remove the existing switch from the wall by detaching the wallplate.

Connect the Fan Control

  1. Connect the green ground wire from the wall box to the green wire on the fan control using a wire connector.
  2. Connect the neutral wire from the wall box to the white wire on the fan control using a wire connector.
  3. Connect the load/tagged wire from the wall box to the yellow wire on the fan control using a wire connector.

Mount the Fan Control

  • Securely mount the fan control in place according to the provided instructions.

Turn Power On

  • After installation, turn the power back on at the circuit breaker.

Set-Up with System

  • Operate the fan control by adjusting between the 4 speeds – High, Medium-High, Medium, and Low. Use the FASS switch for front-accessible service.

FAQ

  • Q: What should I do if my fan does not turn on?
  • A: Check if the fan speed is set too slow. Ensure that you are using it with an AC fan only and follow the wiring diagrams for correct connections.
  • Q: Can I use this fan control with DC motor fans?
  • A: No, this fan control is designed for use with AC fans only. Do not use it with DC motor fans to prevent damage.
  • Q: Is it safe to use this fan control with lighting loads on a fan?
  • A: No, do not use this fan control to control lighting loads on a fan to prevent overheating and potential damage to equipment.

Fan Control

  • Please read before installing
  • RadioRA 3 Fan Control

RRST-ANF

  • 120 V~ 50 / 60 Hz 1.5 A
  • AC fan only

IMPORTANT NOTES

  1. For indoor use only.
  2. Operate between 32 ˚F (0 ˚C) and 104 ˚F (40 ˚C).
  3. Use to control one paddle-type ceiling fan.
  4. Use the ceiling fan’s pull chain to set its speed to the highest setting.
  5. Do not use to control exhaust fans (e.g. bathroom or kitchen exhaust fans).
  6. Do not use to control fans that have integrated fan speed controls other than a pull chain (i.e. fans that have a remote control), unless the integrated control is removed from the ceiling fan.
  7. Do not connect to any other motor-operated appliance or to any lighting load type.
  8. Do not use to control lighting loads on a fan.
  9. Do not use to control DC motor fans.

Installing your fan control

Install the fan

  • Install the fan according to the manufacturer’s instructions and ensure proper operation.

Set the fan speed

  • Set the fan to the highest speed using the pull chains.

Turn the power off at the circuit breaker!

LUTRON-RadioRA-3-Fan-Control-FIG-2

WARNING: SHOCK HAZARD.
May result in serious injury or death. Turn off power at the circuit breaker or fuse before installing

Remove the existing switch from wall

  • Remove the wallplate from the switch.
  • Remove the switch and pull it away from the wall.
  • Place tag on load wire. Disconnect all three wires* from the switch.

LUTRON-RadioRA-3-Fan-Control-FIG-5

Load Ratings (if ganging devices)

LUTRON-RadioRA-3-Fan-Control-FIG-6

Connect the fan control

  1. Connect the bare copper (or green) “ground” wire from the wall box to the green wire on the fan control using a wire connector.
  2. Wrap line/hot wire around screw terminal. Tighten securely to 5 in-lb (0.55 N•m).
  3. Connect the neutral wire from the wall box to the white wire on the fan control using a wire connector.
  4. Connect the load/tagged wire from the wall box to the yellow wire on the fan control using a wire connector.

Mount the fan control

Turn the power on at the circuit breaker

Set-Up with system
For use in a RadioRa 3 system, please refer to www.lutron.com/RA3support. For reliable performance in a system, Clear Connect-Type X devices must be placed within 25 ft (7.6 m) of two additional compatible Clear Connect-Type X devices. Clear Connect-Type X devices include, for example, RadioRA 3 Sunnata dimmer, switch, keypad and RadioRA 3 wireless processor/gateway devices. Companion devices are excluded from the list of compatible devices because they are not Clear Connect-Type X devices. Companion devices have wired communication with the main device. For more information please refer to the Wireless Setup guide: www.lutron.com/RA3support.

Operation

LUTRON-RadioRA-3-Fan-Control-FIG-11

FASS Switch

(Front Accessible Service Switch) Pull the tab out to change the room’s light bulb.

Troubleshooting

LUTRON-RadioRA-3-Fan-Control-FIG-10

CAUTION
Use only with permanently installed ceiling fans. To avoid overheating and possible damage to other equipment, do not use to control receptacles, motor- driven appliances, or transformer-supplied appliances.
Codes
Install following all national and local electrical codes.
Grounding
When no “grounding means” exist in the wall box, the National Electrical Code (NEC®) allows a control to be installed as a replacement if 1) a nonmetallic, noncombustible faceplate is used with nonmetallic attachment screws or 2) the circuit is protected by a ground fault circuit interrupter (GFCI). When installing a control according to these methods, cap or remove the green wire before screwing the control into wall box.

FCC STATEMENT

This device complies with part 15 of the FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:

  1. This device may not cause interference, and
  2. This device must accept any interference, including interference that may cause undesired operation. Modifications not expressly approved by Lutron Electronics Co., Inc. could void the user’s authority to operate this equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, under part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used under the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna
  • Increase the separation between the equipment and the receiver
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected
  • Consult the dealer or an experienced radio/TV technician for help.

This equipment complies with FCC/ISED radiation exposure limits set forth for an uncontrolled environment. The user should avoid prolonged exposure within 7.9 in (20 cm) of the antenna, which may exceed FCC/ISED radio frequency exposure limits.

This Class B digital apparatus complies with Canadian ICES-003. Lutron, the Starburst Logo, FASS and Sunnata are trademarks or registered trademarks of Lutron Electronics Co., Inc. in the US and/or other countries. All other product names, logos, and brands are the property of their respective owners.
© 2024 Lutron Electronics Co. Inc

CONTACT

  • Use our mobile-friendly self-paced installation tool:
  • www.lutron.com/wiringwizard
  • Find more product information:
  • www.lutron.com/support
  • – Videos
  • – Frequently Asked Questions Call us:
  • U.S.A. |Canada|Caribbean
  • 1.844.LUTRON1 (588.7661) (24/7) Mexico
  • +1.888.235.2910 Others
  • +1.610.282.3800

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals