Telycam J.BC.0205.0098 HD PTZ Camera
Product Specifications
- Part Number:
- Drive+ SE 20X-SDI
- Drive+ SE 20X-HDMI
- Video Format:
- SDI: 19201080P60/50/30/25/59.94/29.97/24, 19201080i60/50/59.94, 1280*720P60/50/30/25/59.94/29.97
- HDMI: 19201080P60/50/30/25/59.94/29.97/24, 19201080i60/50/59.94, 1280*720P60/50/30/25/59.94/29.97
- USB: 19201080P60/50/30/25(USB3.0), 1280720P60/50/30(USB3.0), etc.
- Video Interface: SDI, NDI|HX, USB3.0 (for Drive+ SE 20X-SDI)
- Sensor: 1/2.8 2.4MP CMOS sensor
- Control Port: RS232 control port (input/output), HDMI port, 3G-SDI port, USB3.0 port, NDI|HX port, DC12V plug
- Network Speed, Video encode Bit Rate Control, Video Bit Rate, Supported Protocol
- POE+, NDI Daisy Chain, Minimum Lux, White Balance, Exposure, Focus, Iris, Electric Shutter, Gamma, WDR, BLC, etc.
- Pan Tilt Flip, Input Voltage, Dimension, Net Weight
Product Usage Instructions
Safety Guides:
- Never move the camera manually when it is working.
- Put the camera on a fixed and smooth desk or platform to avoid leaned installation.
- Power Supply Polarity should be as per the provided drawing.
Packing List:
Quick Start:
- Check all cable connections before powering on.
- Dial Switch Setting (at the bottom of the camera):
Camera Interface:
- Camera Lens
- Camera Base
- IR Receiver Panel
- Power Indicator Light
- Dial Switch
- Tripod Screw Hole
- HDMI port (optional)
- 3G-SDI port (optional)
- USB3.0 port
- NDI|HX port
- DC12V plug
IR Remote Controller:
- Address Setting: Set camera address by long-pressing SET 1~SET4 until the key light turns on.
- Camera Selection: Short press CAM1~CAM4 to select the relative camera.
- Preset Setting : Long press number key (1-9) to set preset; short press to run preset.
- Clear Preset : Long press CLR PRE to clear all presets.
- Focus Key : Manual focus (valid under manual focus mode).
- Zoom Key: Set the zoom rate.
- Navigate Key : UP/DOWN/LEFT/RIGHT to adjust pan tilt and select menu.
- OK/Home Key: Short press OK to return the camera to HOME position and confirm selections in OSD.
Frequently Asked Questions (FAQ)
-
Can I manually move the camera while it is working?
No, never move the camera manually when it is working to avoid damage to the mechanism. -
How should I set the camera on a desk or platform?
Ensure the camera is placed on a fixed and smooth surface to prevent leaning during installation. -
What should I check before powering on the camera?
Check all cable connections to ensure proper setup before powering on the camera.
SAFETY GUIDES
- Before operation, please fully read and follow all instructions in the manual. For your safety, always keep this manual with the camera.
- The camera power input range is 100 240V AC(50 60Hz),ensure the power supply input within this rate before powering on.
- The camera power voltage is 12V DC, rated currency is 2A. We suggest you use it with the original power supply adapter supplied by the factory.
- Please keep the power cable, video cable and control cable in a safe place. Protect all cables especially the connectors.
- Operational environment: 0℃ 50℃, humidity less than 90%.To avoid any danger, do not put anything inside the camera, and keep away from the corrosive liquid.
- Avoid stress, vibration and damp during transportation, storage and installation.
- Do not detect the camera housing and cover. For any service, please contact authorized technicians.
- Video cable and control cable should be individually shielded, and cannot be substituted with other cables. Do not direct the camera lens towards strong light, such as the sun or the intensive light.
- Use a dry and soft cloth to clean the camera housing. Applied with neutral cleaning agent when there is need to clean. To avoid damage on the camera lens, never use strong or abrasive cleaning agents on the camera housing.
- Do not move the camera by holding the camera head. To avoid mechanical trouble, do not rotate the camera head by hand. NEVER MOVE THE CAMERA MANUALLY WHEN IT IS WORKING.
- Put the camera on fixed and smooth desk or platform, avoid leaned installation.
- Power Supply Polarity (Drawing)
Note:
* The video quality may be affected by the specific frequencies of electromagnetic field.
* Never grasp the head of the camera, and never move the camera by hand when it is working, otherwise, mechanism maybe destroyed.
PACKING LIST
Check all bellow items when open the package:
- Camera 1
- Power Adapter 1
- Power Cable 1
- RS232 Control Cable 1
- USB3.0 Cable 1
- Remote Controller 1
- User Manual 1
- Double sided Adhesive 1
- QC certification 1
QUICK START
-
Check all cable connections before power on.
-
Dial Switch Setting (at the bottom of the camera):
Dial Switch (ARM)
| SW-1| SW-2| Instruction
1| OFF| OFF| Updating mode
2| ON| OFF| Debugging mode
3| OFF| ON| Undefined
4| ON| ON| Working mode
Dial Switch
| SW-3| SW-4| Instruction
1| OFF| OFF| reserve
2| ON| OFF| reserve
3| OFF| ON| reserve
4| ON| ON| reserve
Dial Switch (USB)
| SW-5| SW-6| Instruction
1| OFF| OFF| Updating mode
2| ON| OFF| Working mode
3| OFF| ON| Undefined
4| ON| ON| Undefined
PRODUCT HIGHLIGHTS
- Adopts most advanced ISP, 1/2.8 inch 2.4 MP sensor, providing 1080P60 full HD video resolution.
- Big optical lens: 20x optical zoom , with 60 degree field of view.
- 1080p60 video over IP, H.264, H.265 encoding.
- Support NewTek NDI video transmission and control.
- NDI|HX, HDMI or 3G SDI )), USB outputs, fit for different
- White Balance, Exposure, Focus, Iris can be adjusted automatically or manually.
- Support POE: one single CAT5/6 to get video, control and power supply.
- Special Focusing Algorithm: fast and precise focusing performance when zooming or moving.
- Smooth PTZ mechanical design, accurate pan tilt motor control.
- 128 presets supported; Exposure parameter and white balance parameter can be saved in presets (in manual mode).
- Standard Sony VISCA, IP VISCA, PELCO P, PELCO D control protocol; IP VISCA over both TCP and UDP.
- Daisy chain supported, max 7 cameras connected in VISCA protocol.
- Image flip function, support upside down installation.
- Fast video format switch: less than 3 seconds.
- Supported field upgrade for ISP, ARM, FPGA and USB.
- USB3.0 port compatible with USB2.0 output.
- Support RS232/RS485/UVC control.
- Standard UVC1.5 protocol, seamlessly compatible with major video conferencing software and platform.
- OSD menu in English and Chinese supported. IP address, streaming resolution and size can be set in OSD menu.
CAMERA SPEC
Camera | Drive+ SE 20X-SDI | Drive+ SE 20X-HDMI |
---|---|---|
Part Number | TLC-300-IP-20(NDI)-SDI | TLC-300-IP-20(NDI)-HDMI |
SDI: | HDMI: | |
1920*1080P60/50/30/25/59.94/29.97/24 | 1920*1080P60/50/30/25/59.94/29.97/24 | |
1920*1080i60/50/59.94 | 1920*1080i60/50/59.94 | |
1280*720P60/50/30/25/59.94/29.97 | 1280*720P60/50/30/25/59.94/29.97 | |
**** |
USB:
| 19201080P60/50/30/25(USB3.0); 1280720P60/50/30(USB3.0)
Video Format| 1280720P25(USB3.0&USB2.0); 1024576P30(USB3.0&USB2.0)
| 960540P30(USB2.0); 640360P30(USB2.0); 512288P30(USB2.0)
| IP:
| Main Stream: 19201080@3~60; 1280720@3~60; 1024576@3~60
| Sub Stream: 1280720@3~60; 1024576@3~60; 640360@3~60
| NDI:
| 19201080@3~60, 1280720@3~60, 1024576@3~60,
| 640*360@3~60 (low bandwidth mode)
Video Interface| SDI, NDI|HX, USB3.0| HDMI, NDI|HX, USB3.0
Sensor| 1/2.8”2.4MP CMOS sensor
Zoom| f 4.9~98mm(20X), F1.5- 3.0, View Angle: 60°(Far)-3.2°(Near)
Rotation Angle| Pan: -170° ~ +170°;| Tilt: -30° ~ +90°
Rotation Speed| Pan: 0°~120°/s ;| Tilt: 0°~80°/s
Preset:| Remote controller: 10; RS232: 128; Accuracy: 0.1°
Control Port| RS232, RS485, NDI|HX(VISCA over IP), USB3.0(UVC1.5),
USB2.0(UVC1.1)
---|---
Network Speed| 1000M
Video encode| H.264/H.265
Bit Rate Control| Variable Bit Rate, Constant Bit Rate
Video Bit Rate| 1024Kbps~16384Kbps
Supported Protocol
| TCP/IP, HTTP, RTSP, DHCP ,RTMP, Onvif, NDI(V4.5),
VISCA over IP(TCP&UDP), HTML5, VISCA, PELCO P/D
POE+| Supported
NDI| Supported
Daisy Chain| Support RS232 serial daisy chain
Minimum Lux| 0.1lux
White Balance| ATW/Manual/Auto/Indoor/Outdoor/Push
Exposure| Auto/Manual/Shutter/Iris/Bright
Focus| Auto/Manual
Iris| Auto/Manual
Electric Shutter| Auto/Manual
Gamma| Supported
WDR| Supported
BLC| Supported
2D Noise Reduction| Supported
3D Noise Reduction| Supported
Anti Flicker| OFF/50Hz/60Hz
Pan Tilt Flip| Supported
Input Voltage| DC12V/POE+(IEEE802.3at)
Dimension| 220mm×190mm×173mm
Net Weight| 1.35kg
CAMERA INTERFACE
- Camera Lens
- Camera Base
- IR Receiver Panel
- Power Indicator Light
- Dial Switch
- Tripod Screw Hole
- Installation Hole
- RS232 control port (input)
- RS232 control port(output)
- HDMI port
- 3G SDI port
- USB3.0 port
- NDI|HX port
- DC12V plug
CAMERA DIMENSION (MM)
IR REMOTE CONTROLLER
-
POWER
- Under normal working mode, short press POWER key, to enter standby mode
- Press it again, the camera will do self configuration, then go back to HOME position.
- It will go to preset position if power on model has been set before.
-
FREEZE
Not Supported in USB Short press FREEZE key to freeze/ unfreeze the image. -
IRT (IR Transfer/IR Pass)
Open / close the IR pass function. Once press the IRT key, the camera will receive and Pass the IR remote control signal to the codec/terminal (via VISCA IN port). -
SET 1~SET4 ADDRESS SETTING
Long press for 3seconds until the key light ON, to set camera address. -
CAM1~CAM4 CAMERA SELECTING
Short press to select the relative camera. -
NUMBER KEY 1 9
- Set preset: long press (3 seconds) the number key to set preset.
- Run preset: Short press the number key to run preset.
-
CLR PRE CLEAR PRESET
- CLR PRE+ number key: to clear the relative preset.
- Long press to clear all preset.
-
FOCUS KEY ( ON THE LEFT)
Manual focus, only valid under manual focus model. -
ZOOM KEY( ON THE RIGHT SIDE)
Set the zoom rate. -
NAVIGATE KEY: UP/DOWN/LEFT/RIGHT
Under working mode, use navigate key to set the pan tilt, and select menu when enter OSD. -
OK /HOME KEY
Under working mode, short press OK to make the camera go back to HOME position; and confirm the selection when enter OSD. -
AF: Auto Focus.
-
MF: Manual Focus.
-
RESET: Press 3 seconds to reset camera.
-
MENU: Enter OSD menu.
-
LEARN+LIMIT L key: Set the pan tilt left limit position.
-
LEARN+LIMIT R key: Set the pan tilt right limit position.
-
LEARN+LMT CLR key: Clear the limit position.
-
BLC OFF/ BLC ON: Not Available.
-
BRIGHT-/BRIGHT+: Set image brightness, only valid under bright priority exposure mode.
-
Video Format Keys:
Long press 3 seconds to select different video format output.
VISCA IN (RS232 PORT)
No. | V_IN | V_OUT | VISCA IN | RS485 | |
---|---|---|---|---|---|
1 | DTR | DTR | 1 | ||
2 | DSR | DSR | 2 | ||
3 | TXD | TXD | 3 | ||
4 | GND | GND | 4 | ||
5 | RXD | RXD | 5 | ||
6 | A | 6 | A(+) | ||
7 | IR OUT | 7 | IR OUT | ||
8 | B | 8 | B(-) |
VISCA IN &Mini DIN Connection
Camera VISCA IN | Mini DIN |
---|---|
1 | DTR |
2 | DSR |
3 | TXD |
4 | GND |
5 | RXD |
6 | A(+) |
7 | IR OUT |
8 | B(-) |
VISCA IN & DB9 Connection
Camera VISCA IN | Windows DB-9 |
---|---|
1 | DTR |
2 | DSR |
3 | TXD |
4 | GND |
5 | RXD |
6 | A(+) |
7 | IR OUT |
8 | B(-) |
VISCA Network Construction:
SERIAL PORT CONFIGURATION
Parameter | Value | Parameter | Value |
---|---|---|---|
Baud rate | 2400/4800/9600/115200 | Stop Bit | 1bit |
--- | --- | --- | --- |
Start Bit | 1 bit | Check Bit | None |
Date Bit | 8 bit |
VISCA PROTOCOL
Part1 Camera Return Command
Ack/Completion Message
| Command Packet| Note
ACK| z0 41 FF| Returned when the command is accepted.
Completion| z0 51 FF| Returned when the command has been executed.
Error Messages
| Command Packet| Note
Syntax Error| z0 60 02 FF| Returned when the command format is different or
when a command with illegal command parameters is accepted
Command Not Executable|
z0 61 41 FF
| Returned when a command cannot be executed due to current conditions. For example, when commands controlling the focus manually are received during auto focus.
Part 2 Camera Control Command
Command type| function| command|
---|---|---|---
Address Set| Broadcast| 88 30 01 FF| Address setting
IF_Clear| Broadcast| 88 01 00 01 FF| I/F Clear
Command Cancel| | 8x 21 FF|
CAM_Power
| On| 8x 01 04 00 02 FF| ****
Power ON/OFF
Off| 8x 01 04 00 03 FF
CAM_Zoom
| Stop| 8x 01 04 07 00 FF|
Tele(Standard)| 8x 01 04 07 02 FF
Wide(Standard)| 8x 01 04 07 03 FF
Tele(Variable)| 8x 01 04 07 2p FF| ****
p = 0(low)~7(high)
Wide(Variable)| 8x 01 04 07 3p FF
Direct| 8x 01 04 47 0p 0q 0r 0s FF| pqrs: Zoom Position (0(wide)
~0x4000(tele))
Direct with speed
| ****
8x 0A 04 47 0t 0p 0q 0r 0s FF
| t: spd 0~7
pqrs: Zoom Position (0(wide)
~0x4000(tele))
CAM_DZoom
| ON| 8x 01 04 06 02 FF|
OFF| 8x 01 04 06 03 FF
| Combine Mode| 8x 01 04 36 00 FF| Combine with optical zoom control
---|---|---|---
Separate Mode| 8x 01 04 36 01 FF| Separate with optical zoom control
Stop| 8x 01 04 06 00 FF| Enable In separate mode
Tele (Variable)| 8x 01 04 06 2p FF| Enable In separate mode
Wide (Variable)| 8x 01 04 06 3p FF| Enable In separate mode
Direct| 8x 01 04 46 0p 0q 0r 0s FF| Enable In separate mode
CAM_Focus
| Stop| 8x 01 04 08 00 FF|
Far(Standard)| 8x 01 04 08 02 FF
Near(Standard)| 8x 01 04 08 03 FF
Far (Variable)| 8x 01 04 08 2p FF| p=0 (Low) to 7 (High)
Near (Variable)| 8x 01 04 08 3p FF| p=0 (Low) to 7 (High)
Direct| 8x 01 04 48 0p 0q 0r 0s FF| pqrs: Focus Position
Auto Focus| 8x 01 04 38 02 FF|
Manual Focus| 8x 01 04 38 03 FF|
One Push AF| 8x 01 04 18 01 FF|
CAM_Zoom Focus
| ****
Direct
| 8x 01 04 47 0p 0q 0r 0s 0t 0u 0v 0w FF| pqrs: Zoom Position (0(wide)~ 0x4000(tele))
tuvw: Focus Position
CAM_WB
| Auto| 8x 01 04 35 00 FF|
Indoor| 8x 01 04 35 01 FF|
Outdoor| 8x 01 04 35 02 FF|
One Push| 8x 01 04 35 03 FF|
ATW| 8x 01 04 35 04 FF|
Manual| 8x 01 04 35 05 FF|
Sodium lamp| 8x 01 04 35 08 FF|
fluorescent| 8x 01 04 35 09 FF|
One Push Trigger| 8x 01 04 10 05 FF|
CAM_R Gain
| Reset| 8x 01 04 03 00 FF| ****
Manual Control of R Gain
Up| 8x 01 04 03 02 FF
Down| 8x 01 04 03 03 FF
Direct| 8x 01 04 43 00 00 0p 0q FF| pq: R Gain (0~0xFF)
CAM_B gain
| Reset| 8x 01 04 04 00 FF| ****
Manual Control of B Gain
Up| 8x 01 04 04 02 FF
Down| 8x 01 04 04 03 FF
Direct| 8x 01 04 44 00 00 0p 0q FF| pq: B Gain (0-0xFF)
CAM_AE| Full Auto| 8×01 04 39 00 FF| Automatic Exposure mode
| Manual| 8x 01 04 39 03 FF| Manual Control mode
---|---|---|---
Shutter Priority| 8x 01 04 39 0A FF| Shutter Priority
Automatic Exposure mode
Iris Priority| 8x 01 04 39 0B FF| Iris Priority Automatic
Exposure mode
Bright| 8x 01 04 39 0D FF| Bright Mode (Manual control)
CAM_Shutter
| Reset| 8x 01 04 0A 00 FF| ****
Shutter Setting
Up| 8x 01 04 0A 02 FF
Down| 8x 01 04 0A 03 FF
Direct| 8x 01 04 4A 00 00 0p 0q FF| pq: Shutter Position (0~0x15)
CAM_Iris
| Reset| 8x 01 04 0B 00 FF| ****
Iris Setting(0~0xD)
Up| 8x 01 04 0B 02 FF
Down| 8x 01 04 0B 03 FF
Direct| 8x 01 04 4B 00 00 0p 0q FF| pq: Iris Position (0~ 0x11)
CAM_Gain
| Reset| 8x 01 04 0C 00 FF| ****
Gain Setting (0~0x0F)
Up| 8x 01 04 0C 02 FF
Down| 8x 01 04 0C 03 FF
Direct| 8x 01 04 0C 00 00 0p 0q FF| pq: Gain Positon (0~0x0E)
CAM_Bright
| Reset| 8x 01 04 0D 00 FF| ****
Bright Setting
Up| 8x 01 04 0D 02 FF
Down| 8x 01 04 0D 03 FF
Direct| 8x 01 04 4D 00 00 0p 0q FF| pq: Bright l Positon (0~0x1B)
CAM_WDR
| On| 8x 01 04 3D 02 FF| ****
Exposure Compensation ON/OFF
Off| 8x 01 04 3D 03 FF
Direct| 8x 01 04 D3 pq FF| pq: ExpComp Position (0~0x6)
CAM_Back Light(BLC)
| On| 8x 01 04 33 02 FF| BackLight On
Off| 8x 01 04 33 03 FF| BackLight Off
CAM_Sharpness
| Reset| 8x 01 04 02 00 FF| ****
Aperture Control
Up| 8x 01 04 02 02 FF
Down| 8x 01 04 02 03 FF
Direct| 8x 01 04 42 00 00 0p 0q FF| pq: Aperture Gain (0~0x0F)
CAM_Memory(preset)
| Reset| 8x 01 04 3F 00 pp FF| ****
pp: Preset Number(=0 to 127) Corresponds to 0 to 9 on the Remote Commander
Set| 8x 01 04 3F 01 pp FF
Recall| 8x 01 04 3F 02 pp FF
CAM_LR_Reverse
| On| 8x 01 04 61 02 FF| ****
Image Flip Horizontal ON/OFF
Off| 8x 01 04 61 03 FF
CAM_Picture Flip
| On| 8x 01 04 66 02 FF| ****
Image Flip Vertical ON/OFF
---|---|---|---
Off| 8x 01 04 66 03 FF
CAM_RS485Ctl
| On| 8x 01 06 A5 02 FF|
Off| 8x 01 06 A5 03 FF
CAM_Saturation| Saturation| 8x 01 04 A1 00 00 0p 0q FF| pq:saturation level
0x00~0x0f
CAM_Contrast| Contrast| 8x 01 04 A2 00 00 0p 0q FF| pq:Contrast level
0x00~0x0f
CAM_Speed By Zoom
| On| 8x 01 06 A0 02 FF|
Off| 8x 01 06 A0 03 FF
CAM_PT Speed| PT Speed| 8x 01 04 C1 00 00 0p 0q FF| pq: PT speed 0x05~0x18
CAM_Zoom Speed| Zoom Speed| 8x 01 04 D1 00 00 0p 0q FF| pq: Zoom speed
0x01~0x07
CAM_Zoom Display
| On| 8x 01 06 C2 02 FF|
Off| 8x 01 06 C2 03 FF|
CAM_Freeze| Freeze| 8x 01 04 75 0p FF| p: Freeze switch 3=OFF, 2=ON
CAM_Preset Freeze Set| Preset Freeze Set| 8x 01 04 76 0p FF| p: Preset Freeze
switch 3=OFF, 2=ON
CAM_Preset Speed Set| Preset Speed Set| 8x 01 7E 01 0B pp qq FF| pp: Preset
NO.
qq: Preset Speed 2~24 default:15
CAM_Preset Speed Adj| Preset Speed Adj| 8x 01 7E 01 1B 0p FF| p: Adjustment of direction
3=down, 2=up
CAM_IR address| IR address| 8x 01 06 D8 0p FF| p:IR address 1~4
CAM_Gamma| Gamma set| 8x 01 04 5B 0p FF| P:Gamma NO. (0~4)
CAM_2D
Noise Reduction
| Direct| 8x 01 04 A5 0p FF| (0~0x01)
CAM_3D
Noise Reduction
| Direct| 8x 01 04 53 0p FF| (0~0x05)
FLICK
| 50HZ| 8x 01 04 23 01 FF|
60HZ| 8x 01 04 23 02 FF|
OFF| 8x 01 04 23 00 FF|
Video System Set(Factory)
| | ****
8x 01 06 35 00 pp FF
| pp: Video format
1080P60 0x00
1080P50 0x01
1080I60 0x02
1080I50 0x03
1080P30 0x04
1080P25 0x05
720P60 0x06
720P50 0x07
720P30 0x08
720P25 0x09
1080P5994 0x0E
1080I5994 0x0F
1080P2997 0x10
720P5994 0x13
720P2997 0x14
1080P24 0x11
1080P2398 0x12
Video System Set(Sony)
| | ****
8x 01 04 24 72 0p 0q FF
| pq: Video format
1080P60 0x2e
1080P50 0x2f
1080I60 0x01
| | | 1080I50 0x04
1080P30 0x06
1080P25 0x08
720P60 0x09
720P50 0x0c
720P30 0x0e
720P25 0x11
1080P5994 0x13
1080I5994 0x02
1080P2997 0x07
720P5994 0x0a
720P2997 0x0f
1080P24 0x2a
1080P2398 0x2b
---|---|---|---
CAM_ID Write| | 8x 01 04 22 0p 0q 0r 0s FF| pqrs: Camera ID (=0000 to FFFF)
DHCP control
| DHCP off| 8x 01 04 AE 00 FF| DHCP off
DHCP on| 8x 01 04 AE 01 FF| DHCP on
IP address control
| IP set| 8x 01 04 AB 0p 0q 0r 0s 0m 0n
0x 0y FF
| Set ip to :pq.rs.mn.xy
Mask set| 8x 01 04 AC 0p 0q 0r 0s 0m 0n
0x 0y FF
| Set mask to :pq.rs.mn.xy
Gateway set| 8x 01 04 AD 0p 0q 0r 0s 0m 0n
0x 0y FF
| Set gateway to : pq.rs.mn.xy
Mainstream
| ****
resolution
| ****
8x 01 04 C2 00 0p 0q 0r 0s 0m 0n 0x 0y FF
| pqrs : Column(x size) mnxy: Line (y size) only support:
19201080 1280720 1024*576
rate| 8x 01 04 C2 01 0p 0q 0r 0s 0m
0n 0x 0y FF
| pqrsmnxy: bitrate
(1024~16384kbps)
Encode Mode
| ****
8x 01 04 C2 02 0p 0q FF
| Mode sel:0xpq
0x00:h264
0x01:h265
Frame Rate| 8x 01 04 C2 03 0p 0q FF| Frame rate:0xpq (3~60)
IDR| 8x 01 04 C2 04 0p 0q FF| IDR Setting:0xpq (3~120)
Stream Rate Mode
| ****
8x 01 04 C2 05 0p 0q FF
| Contor mode:0xpq
0x00:CBR
0x01:VBR
Sub stream
| ****
resolution
| ****
8x 01 04 C3 00 0p 0q 0r 0s 0m 0n 0x 0y FF
| pqrs : Column(x size)
mnxy: Line (y size)
only support: 640*360
rate| 8x 01 04 C3 01 0p 0q 0r 0s 0m 0n 0x 0y FF| pqrsmnxy: bitrate (1024~2048kbps)
Encode Mode
| ****
8x 01 04 C3 02 0p 0q FF
| Mode sel:0xpq
0x00:h264
0x01:h265
Frame Rate| 8x 01 04 C3 03 0p 0q FF| Frame rate:0xpq
(3~60)
IDR| 8x 01 04 C3 04 0p 0q FF| IDR Setting:0xpq
(3~120)
Stream Rate Mode
| ****
8x 01 04 C3 05 0p 0q FF
| Contor mode:0xpq
0x00:CBR
0x01:VBR
Color adjust
| Color adjust OFF| 8x 01 04 B6 00 FF| Color adjust off
Color adjust ON| 8x 01 04 B6 01 FF| Color adjust on
brightness balance
OFF
| 8x 01 04 B7 00 FF| Keep Brightness
brightness balance
ON
| 8x 01 04 B7 01 FF| No keep Brightness
| Flare red| 8x 01 04 B8 dat FF| Flare mode red value
Default is 32
---|---|---|---
Flare green| 8x 01 04 B9 dat FF| Flare mode green value
Default is 32
Flare green| 8x 01 04 BA dat FF| Flare mode blue value
Default is 32
SYS_Menu
| Menu On| 8x 01 06 06 02 FF| Turn on the menu
Menu Off| 8x 01 06 06 03 FF| Turn off the menu
Menu Back| 8x 01 06 06 10 FF| Menu step back
Menu OK| 8x 01 7E 01 02 00 01 FF| Menu ok
IR_Receive
| On| 8x 01 06 08 02 FF| ****
IR(remote commander)receive ON/OFF
Off| 8x 01 06 08 03 FF
On/Off| 8x 01 06 08 10 FF
Cam_Tally
| ****
RGB
| ****
8x 01 7E 01 0A 00 0p FF
| P=0: OFF
P=1: RED
P=2: GREEN
P=3: RED&GREEN
P=4: BLUE
P=5: RED&BLUE P=6: GREEN&BLUE
P=7: RED&GREEN&BLUE
Pan_tilt Drive
| Up| 8x 01 06 01 VV WW 03 01 FF| ****
VV: Pan speed 0x01 (low speed) to 0x18 (high speed)
WW: Tilt speed 0x01 (low speed) to 0x14 (high speed)
YYYY: Pan Position(TBD) ZZZZ: Tilt Position(TBD)
Down| 8x 01 06 01 VV WW 03 02 FF
Left| 8x 01 06 01 VV WW 01 03 FF
Right| 8x 01 06 01 VV WW 02 03 FF
Up left| 8x 01 06 01 VV WW 01 01 FF
Up right| 8x 01 06 01 VV WW 02 01 FF
Down Left| 8x 01 06 01 VV WW 01 02 FF
Down Right| 8x 01 06 01 VV WW 02 02 FF
Stop| 8x 01 06 01 VV WW 03 03 FF
Absolute Position| 8x 01 06 02 VV WW
0Y 0Y 0Y 0Y 0Z 0Z 0Z 0Z FF
Relative Position| 8x 01 06 03 VV WW
0Y 0Y 0Y 0Y 0Z 0Z 0Z 0Z FF
Home| 8x 01 06 04 FF
Reset| 8x 01 06 05 FF
Pan-tilt Limit Set
| Set| 8x 01 06 07 00 0W
0Y 0Y 0Y 0Y 0Z 0Z 0Z 0Z FF
| W:1 Up Right 0:Down Left YYYY: Pan Limit Position(TBD) ZZZZ: Tilt Limit
Position(TBD)
Clear| 8x 01 06 07 01 0W
07 0F 0F 0F 07 0F 0F 0F FF
Part 3 Camera Lnquiry Command
Command type | command | return | note |
---|---|---|---|
CAM_Power Inq | 8x 09 04 00 FF | y0 50 02 FF | On |
y0 50 03 FF | Off(Standby) | ||
CAM_Zoom Pos Inq | 8x 09 04 47 FF | y0 50 0p 0q 0r 0s FF | pqrs: Zoom Position |
CAM_DZoom On Off Inq | 8x 09 04 06 FF | y0 50 0p FF | p 2: ON 3: OFF |
--- | --- | --- | --- |
CAM_DZoom Mode Inq | 8x 09 04 36 FF | y0 50 0p FF | p 0:combination mode |
1:separate mode
CAM_DZoom Posi Inq| 8x 09 04 46 FF| y0 50 0p 0q 0r 0s FF| pqrs: Zoom Position
CAM_Speed By Zoom Inq| 8x 09 06 A0 FF| y0 50 0p FF| p 2: ON 3: OFF
CAM_PT Speed Inq(IR)| 8x 09 04 C1 FF| y0 50 pp FF| pp: 0x05~0x18
CAM_Zoom Speed Inq(IR)| 8x 09 04 D1 FF| y0 50 0p FF| p:0x00~0x07
CAM_Focus Mode Inq| 8x 09 04 38 FF| y0 50 02 FF| Auto Focus
y0 50 03 FF| Manual Focus
CAM_Focus Pos Inq| 8x 09 04 48 FF| y0 50 0p 0q 0r 0s FF| pqrs: Focus Position
CAM_2D_Inq| 8x 09 04 A5 FF| y0 50 03 FF| (0~0x01)
p: 0: off 1: on
CAM_3D_Inq
| ****
8x 09 04 53 FF
| ****
y0 50 03 FF
| (0~0x05)
p:0:off 1: auto 2~5: noise level
CAM_WB Mode Inq
| ****
8x 09 04 35 FF
| y0 50 00 FF| Auto
y0 50 01 FF| Indoor mode
y0 50 02 FF| Outdoor mode
y0 50 03 FF| OnePush mode
y0 50 04 FF| ATW
y0 50 05 FF| Manual
CAM_RGain Inq| 8x 09 04 43 FF| y0 50 00 00 0p 0q FF| pq: R Gain
CAM_BGain Inq| 8x 09 04 44 FF| y0 50 00 00 0p 0q FF| pq: B Gain
CAM_Saturation Inq| 8x 09 04 A1 FF| y0 50 00 00 0p 0q FF| pq: saturation
CAM_Contrast Inq| 8x 09 04 A2 FF| y0 50 00 00 0p 0q FF| pq: contrast
CAM_AE Mode Inq
| ****
8x 09 04 39 FF
| y0 50 00 FF| Full Auto
y0 50 03 FF| Manual
y0 50 0A FF| Shutter priority
y0 50 0B FF| Iris priority
y0 50 0D FF| Bright
CAM_Flicker Mode Inq
| ****
8x 09 04 AA FF
| ****
y0 50 0p FF
| p 0: OFF
1: 50HZ
2: 60HZ
CAM_Shutter Pos Inq| 8x 09 04 4A FF| y0 50 00 00 0p 0q FF| pq: Shutter
Position
CAM_Iris Pos Inq| 8x 09 04 4B FF| y0 50 00 00 0p 0q FF| pq: Iris Position
CAMGain Posi Inq| 8x 09 04 4C FF| y0 50 00 00 0p 0q FF| pq: Gain Position
CAM Bright Posi Inq| 8x 09 04 4D FF| y0 50 00 00 0p 0q FF| pq: Bright
Position
CAM_WDR Mode Inq| 8x 09 04 3D FF| y0 50 02 FF| On
y0 50 03 FF| Off
CAM_WDR Pos Inq| 8x 09 04 D3 FF| y0 50 0p FF| p: WDR Position
CAM_Aperture Inq| 8x 09 04 42 FF| y0 50 00 00 0p 0q FF| pq: Aperture Gain
CAM_Preset Exist Inq
| 8x 09 04 3F pp FF| ****
y0 50 0q FF
| pp: Memory number
q: 1=preset exist 0=preset not saved
SYS_Menu Mode Inq| 8x 09 06 06 FF| y0 50 02 FF| On
y0 50 03 FF| Off
CAM_LR_Reverse Inq| 8x 09 04 61 FF| y0 50 02 FF| On
y0 50 03 FF| Off
CAM_Picture Flip Inq| 8x 09 04 66 FF| y0 50 02 FF| On
y0 50 03 FF| Off
CAM_ID Inq| 8x 09 04 22 FF| y0 50 0p 0q 0r 0s FF| pqrs: Camera ID
CAM_DHCP Inq| 8x 09 04 AE FF| y0 50 pp FF|
CAM_IP Inq| 8x 09 04 AB FF| y0 50 0p 0p 0q 0q 0r 0r
0s 0s FF
|
CAM_MASK Inq| 8x 09 04 AC FF| y0 50 0p 0p 0q 0q 0r 0r
0s 0s FF
|
---|---|---|---
CAM_GATEWAY Inq| 8x 09 04 AD FF| y0 50 0p 0p 0q 0q 0r 0r
0s 0s FF
|
CAM_Flare Mode Inq| 8x 09 04 B6 FF| y0 50 pp FF|
CAM_Flare Bright Mode Inq| 8x 09 04 B7 FF| y0 50 pp FF|
CAM_Flare Red| 8x 09 04 B8 FF| y0 50 pp FF|
CAM_Flare Green| 8x 09 04 B9 FF| y0 50 pp FF|
CAM_Flare Blue| 8x 09 04 BA FF| y0 50 pp FF|
CAM_Version Inq| 8x 09 00 02 FF| y0 50 ab cd
mn pq rs tu vw FF
|
Video System Inq(Factory)| 8x 09 06 23 FF| y0 50 pp FF| pp: Video format
Video System Inq(Sony)| 8x 09 04 24 72
FF
| y0 50 0p 0p FF| pp: Video format
IR_Transfer| 8x 09 06 1A FF| y0 50 02 FF| On
y0 50 03 FF| Off
IR_Receive| 8x 09 06 08 FF| y0 50 02 FF| On
y0 50 03 FF| Off
Pan-tilt Max Speed Inq| 8x 09 06 11 FF| y0 50 ww zz FF| ww: Pan Max Speed zz:
Tilt Max Speed
Pan-tilt Pos Inq| 8x 09 06 12 FF| y0 50 0w 0w 0w 0w
0z 0z 0z 0z FF
| wwww: Pan Position zzzz: Tilt Position
Mainstream Resolution Inq
| ****
8x 09 04 C2 00 FF
| ****
y0 50 0p 0q 0r 0s 0m 0n 0x 0y FF
| pqrs : Column(x size)
mnxy: Line (y size) only support: 1920*1080
1280*720
1024*576
Main stream Rate Inq| 8x 09 04 C2 01
FF
| y0 50 0p 0q 0r 0s 0m 0n
0x 0y FF
| pqrsmnxy: bitrate (1024~16384kbps)
Main Encode Mode Inq
| 8x 09 04 C2 02 FF| ****
y0 50 pp FF
| Mode sel:0xpp
0x00:h264
0x01: h265
Main Frame Rate Inq| 8x 09 04 C2 03
FF
| y0 50 pp FF| Frame rate:0xpp
(3~60)
Main IDR Inq| 8x 09 04 C2 04
FF
| y0 50 pp FF| IDR Setting:0xpp
(3~120)
Main Stream Rate Mode Inq
| 8x 09 04 C2 05 FF| ****
y0 50 pp FF
| Contor mode:0xpp
0x00:CBR
0x01:VBR
Sub stream Resolution Inq
| ****
8x 09 04 C3 00 FF
| ****
y0 50 0p 0q 0r 0s 0m 0n 0x 0y FF
| pqrs : Column(x size)
mnxy: Line (y size) only support:
640*360
Sub stream Rate Inq| 8x 09 04 C3 01
FF
| y0 50 0p 0q 0r 0s 0m 0n
0x 0y FF
| pqrsmnxy: bitrate (1024~2048kbps)
Sub Encode Mode Inq
| 8x 09 04 C3 02 FF| ****
y0 50 pp FF
| Mode sel:0xpp
0x00:h264
0x01: h265
Sub Frame Rate Inq| 8x 09 04 C3 03
FF
| y0 50 pp FF| Frame rate:0xpp
(3~60)
Sub ID RInq| 8x 09 04 C3 04
FF
| y0 50 pp FF| IDR Setting:0xpp
(3~120)
Sub Stream Rate Mode Inq
| 8x 09 04 C3 05 FF| ****
y0 50 pp FF
| Contor mode:0xpp
0x00:CBR
0x01:VBR
VISCA PAN TILT ABSOLUTE POSITION VALUE
Pan Angle | VISCA Value | Tilt Angle | VISCA Value |
---|---|---|---|
-170 | 0xF670 | -30 | 0xFE50 |
-135 | 0xF868 | 0 | 0x0000 |
-90 | 0xFAF0 | 30 | 0x01B0 |
-45 | 0xFD78 | 60 | 0x0360 |
0 | 0x0000 | 90 | 0x510 |
45 | 0x0288 | ||
90 | 0x0510 | ||
135 | 0x0798 | ||
170 | 0x0990 |
VISCA PAN TILT SPEED VALUE
Pan(Degree/Second) | Pan(Degree/Second)) |
---|---|
0 | 0.3 |
1 | 1 |
2 | 1.5 |
3 | 2.2 |
4 | 2.4 |
5 | 2.6 |
6 | 2.8 |
7 | 3.0 |
8 | 3.2 |
9 | 3.4 |
10 | 3.8 |
11 | 4.5 |
12 | 6 |
13 | 9 |
14 | 15 |
15 | 19 |
16 | 25 |
17 | 32 |
18 | 38 |
19 | 45 |
20 | 58 |
21 | 75 |
22 | 88 |
23 | 105 |
24 | 120 |
PELCO-D Protocol Command List
Function| Byte1| Byte2| Byte3| Byte4| Byte5|
Byte6| Byte7
---|---|---|---|---|---|---|---
Up| 0xFF| Address| 0x00| 0x08| Pan Speed| Tilt Speed| SUM
Down| 0xFF| Address| 0x00| 0x10| Pan Speed| Tilt Speed| SUM
Left| 0xFF| Address| 0x00| 0x04| Pan Speed| Tilt Speed| SUM
Right| 0xFF| Address| 0x00| 0x02| Pan Speed| Tilt Speed| SUM
Up left| 0xFF| Address| 0x00| 0x0C| Pan Speed| Tilt Speed| SUM
Up right| 0xFF| Address| 0x00| 0x0A| Pan Speed| Tilt Speed| SUM
Down Left| 0xFF| Address| 0x00| 0x14| Pan Speed| Tilt Speed| SUM
Down Right| 0xFF| Address| 0x00| 0x12| Pan Speed| Tilt Speed| SUM
Zoom In| 0xFF| Address| 0x00| 0x20| 0x00| 0x00| SUM
Zoom Out| 0xFF| Address| 0x00| 0x40| 0x00| 0x00| SUM
Focus Far| 0xFF| Address| 0x00| 0x80| 0x00| 0x00| SUM
Focus Near| 0xFF| Address| 0x01| 0x00| 0x00| 0x00| SUM
Set Preset| 0xFF| Address| 0x00| 0x03| 0x00| Preset ID| SUM
Stop| 0xFF| Address| 0x00| 0x00| Pan Speed| Tilt Speed| SUM
Clear Preset| 0Xff| Address| 0x00| 0x05| 0x00| Preset ID| SUM
Call Preset| 0Xff| Address| 0x00| 0x07| 0x00| Preset ID| SUM
Query Pan Position| 0Xff| Address| 0x00| 0x51| 0x00| 0x00| SUM
Query Pan Position Response| 0Xff| Address| 0x00| 0x59| Value High Byte| Value
Low Byte| SUM
Query Tilt Position| 0Xff| Address| 0x00| 0x53| 0x00| 0x00| SUM
Query Tilt Position Response| 0Xff| Address| 0x00| 0x5B| Value High Byte|
Value Low Byte| SUM
Query Zoom Position| 0Xff| Address| 0x00| 0x55| 0x00| 0x00| SUM
Query Zoom Position Response| 0Xff| Address| 0x00| 0x5D| Value High Byte|
Value Low Byte| SUM
PELCO-P Protocol Command List
Function | Byte1 | Byte2 | Byte3 | Byte4 | Byte5 | Byte6 | Byte7 | Byte8 |
---|---|---|---|---|---|---|---|---|
Up | 0Xa0 | Address | 0x00 | 0x08 | Pan Speed | Tilt Speed | 0Xaf | XOR |
Down | 0Xa0 | Address | 0x00 | 0x10 | Pan Speed | Tilt Speed | 0Xaf | XOR |
Left | 0Xa0 | Address | 0x00 | 0x04 | Pan Speed | Tilt Speed | 0Xaf | XOR |
Right | 0Xa0 | Address | 0x00 | 0x02 | Pan Speed | Tilt Speed | 0Xaf | XOR |
Up left | 0Xa0 | Address | 0x00 | 0x0C | Pan Speed | Tilt Speed | 0Xaf | XOR |
Up right | 0Xa0 | Address | 0x00 | 0x0A | Pan Speed | Tilt Speed | 0Xaf | XOR |
Down Left | 0Xa0 | Address | 0x00 | 0x14 | Pan Speed | Tilt Speed | 0Xaf | XOR |
Down Right | 0Xa0 | Address | 0x00 | 0x12 | Pan Speed | Tilt Speed | 0Xaf | XOR |
Zoom In | 0Xa0 | Address | 0x00 | 0x20 | 0x00 | 0x00 | 0Xaf | XOR |
Zoom Out | 0Xa0 | Address | 0x00 | 0x40 | 0x00 | 0x00 | 0Xaf | XOR |
Focus Far | 0Xa0 | Address | 0x00 | 0x80 | 0x00 | 0x00 | 0Xaf | XOR |
Focus Near | 0Xa0 | Address | 0x01 | 0x00 | 0x00 | 0x00 | 0Xaf | XOR |
Stop | 0Xa0 | Address | 0x00 | 0x00 | Pan Speed | Tilt Speed | 0Xaf | XOR |
Set Preset | 0xA0 | Address | 0x00 | 0x03 | 0x00 | Preset ID | 0xAF | XOR |
Clear Preset | 0xA0 | Address | 0x00 | 0x05 | 0x00 | Preset ID | 0xAF | XOR |
Call Preset | 0xA0 | Address | 0x00 | 0x07 | 0x00 | Preset ID | 0xAF | XOR |
Query Pan Position | 0xA0 | Address | 0x00 | 0x51 | 0x00 | 0x00 | 0xAF | XOR |
Query Pan
Position Response
| ****
0xA0
| ****
Address
| ****
0x00
| ****
0x59
| Value High Byte| Value Low Byte| ****
0xAF
| ****
XOR
Query Tilt Position| 0xA0| Address| 0x00| 0x53| 0x00| 0x00| 0xAF| XOR
Query Tilt
Position Response
| ****
0xA0
| ****
Address
| ****
0x00
| ****
0x5B
| Value High Byte| Value Low Byte| ****
0xAF
| ****
XOR
Query Zoom Position| 0xA0| Address| 0x00| 0x55| 0x00| 0x00| 0xAF| XOR
Query Zoom Position
Response
| ****
0xA0
| ****
Address
| ****
0x00
| ****
0x5D
| Value High Byte| Value Low Byte| ****
0xAF
| ****
XOR
OSD MENU
-
Under working mode, press the MENU key on the IR remote controller, to enter the OSD menu as bellow:
-
After enter the main menu, use the navigate UP/DOWN key to select the main menu. Once been selected, the main menu will change to blue background, and the right side will show all sub menu options.
-
Press the navigate RIGHT key to enter sub menu; use UP/DONW key to select the sub menu; use LEFT/RIGHT key to select parameter.
-
Press the MENU key again to return to previous menu. Press the MENU key continuously to exit the OSD menu.
-
OSD Menu Setting List
SYSTEM
| PROTOCOL| Optional item:VISCA、PLC.P、PLC.D| Default:VISCA
---|---|---|---
ADDRESS| VISCA:1~7 PLC.P/PLC.D:1~255| Default:1
BAUD RATE| Optional item:2400、4800、9600、115200| Default:9600
PTL LOCK| Protocol lock: once set, above protocol setting will be locked|
Default:OFF
RS485| RS485 ON/OFF| Default:ON
VISCA| Optional Item: OVER ALL、OVER IP、OVER COM| Default:OVER ALL
LANGUAGE| Optional Item: Chinese、English| Default:English
EXPOSURE
| EXPOSURE
MODE
|
AUTO、MANUAL、SHUTTER、IRIS、BRIGHT
|
Default:AUTO
---|---|---|---
SHUTTER
| Shutter speed: 1/30~1/10000, only valid under MANUAL and
SHUTTER mode
|
Default:AUTO
IRIS
| Iris setting: CLOSE~F1.8, only valid under MANUAL and IRIS
mode
|
Default:AUTO
GAIN| Gain setting: 0dB~30dB , only valid under MANUAL mode| Default:AUTO
EBRIGHT| Bright setting: 0~27, only valid under BRIGHT priority mode.|
Default:AUTO
BRIGHT| 0~15| Default:8
WD MODE| ON/OFF| Default:OFF
WD LEVEL| WDR Level| Default:1
BLC| ON/OFF| Default:OFF
IMAGE
|
WB MODE
| Optional:ATW、MANUAL、AUTO、INDOOR、OUTDOOR、 PUSH|
Default:ATW
---|---|---|---
R GAIN| Red gain level: 0~255, only valid under manual white balance mode|
Default:AUTO
B GAIN| Blue gain level:0~255 , only valid under manual white balance mode|
Default:AUTO
FLICK| Anti-Flicker setting:50/60HZ, to reduce the video flicker| Default:50HZ
DZOOM| ON/OFF| Default:OFF
FOCUS| Select focus mode| Default:AUTO
QUALITY
|
2D NR
| 2D noise reduction: the bigger value is, the less noise on image
is, the lower resolution is.
|
Default:OFF
---|---|---|---
3D NR
| 3D noise reduction: OFF/AUTO/0~4, the bigger value is, the less motion noise on image is. High value will cause image
smear.
|
Default:AUTO
SHARPNESS
| Sharpness setting: 0~15, the higher value is, edge of the image
will be sharpen
|
Default:3
CONTRAST| Set contrast level| Default:8
SATURATION| Set saturation.| Default:8
GAMMA| Select gamma level| Default:0
AF SENSITIVITY
|
Optional:LOW/NORMAL/HIGH
| Default:
NORMAL
PTZ
|
SPEEDBYZ
| Speed By Zoom: proportional speed, the bigger the zoom is, the
slower the speed is
|
Default:ON
---|---|---|---
FLIP.HOR| Flip horizontal| Default:OFF
FLIP VER| Flip vertical| Default:OFF
PT SPD| Pan Tilt speed| Default:18
ZOOM SPD| Zoom speed| Default:5
MENU MIR| Optional Item: NORMAL、MIRROR| Default:NORMAL
PRE FRZ| Open/Close Video Freeze when running presets| Default:OFF
PRE PTSPD| Preset head speed: 2~24| Default:15
PRE ZSPD| Preset zoom speed: 1~7| Default:5
FORMAT
| 1080P59.94| 1080P50|
After selecting the system, press OK to switch the system. If it is the currently selected system, it will not be activated
---|---|---|---
1080I59.94| 1080I50
1080P29.97| 1080P25
720P59.94| 720P50
720P29.97| 720P25
1080P60| 1080P30
720P60| 720P30
1080I60| 1080P24
IP
| DHCP| ON/OFF|
Using up/down/left/right navigation button to select item to set, and using number button to set parameter.
Press menu button to return.
---|---|---|---
IP| 192.168.001.188
MASK| 255.255.255.000
GW (Gateway)| 192.168.001.001
MAIN| Default:19201080
BITRATE| Default:04096k
SUB| Default:1280720
BITRATE| Default:02048k
RESET
| SYS RESET| Reset communication parameter to default
---|---|---
CAM RESET| Reset camera parameter to default
PT RESET| Reset pan/tilt parameter to default
ALL RESET| Reset all parameter to default
INFO
| IR ADDR| Camera IR control address
---|---|---
USB| USB firmware version
CLIENT| Default client end protocol: VISCA
MODEL NO.| Model number
ARM VER| ARM firmware version
FPGA VER| FPGA firmware version
CAM VER| Camera version
RELEASE| Software release date
Set IP Address in Menu
In order to facilitate customer debugging, the camera has the support menu to
set IP address. The specific methods are as follows:
-
Press “MENU” to open the menu interface, select “network parameters” in the menu to call up the IP setting interface:
-
Right click the remote control to enter the IP setting interface, and select the parameters to be set by using the navigation up and down keys, and then select the IP address, mask, gateway:
-
Short press the number key to set the corresponding parameters. After setting the current parameters, press the “MENU” key again to complete the current parameter setting;
-
To exit the menu, just press the “MENU” key again.
UVC CONTROL
- Only run the client software after the USB3.0 camera has completed self-configuration (the IR indicator in blue color and will not flash); otherwise may cause black video issue.
- Make sure the USB3.0 camera is recognized by the PC Device Manager.
- Make sure the interval of video format switching more than 3 seconds, otherwise black video maybe caused.
- Make sure the interval of control command sending from the server (via USB) to the camera no less than 250ms.
- Support standard UVC interface.
PU_BRIGHTNESS_CONTROL| 81 01 04 4d 00 00 0p 0q FF
---|---
PU_CONTRAST_CONTROL| 81 01 04 A2 00 00 0p 0q FF
PU_SATURATION_CONTROL| 81 01 04 A1 00 00 0p 0q FF
PU_SHARPNESS_CONTROL| 8x 01 04 42 00 00 0p 0q FF
PU_GAMMA_CONTROL| 8x 01 04 5B 0p FF
PU_WHITE_BALANCE_TEMPERATURE_CONTROL| 8x 01 04 35 0X FF
PU_BACKLIGHT_COMPENSATION_CONTROL| 81 01 04 33 02/03 FF
PU_POWER_LINE_FREQUENCY_CONTROL| 8x 01 04 AA 00/01/02 FF
CT_ZOOM_ABSOLUTE_CONTROL| 8x 01 04 47 0p 0q 0r 0s FF
CT_PANTILT_ABSOLUTE_CONTROL| 8x 01 06 02 VV WW 0Y 0Y 0Y 0Y 0Z 0Z 0Z 0Z F
CT_PANTILT_RELATIVE_CONTROL| 8x 01 06 01 pp qq rr ss FF
CT_ZOOM_RELATIVE_CONTROL| 8x 01 04 07 pp FF
WEB SETTING
It is not necessary to install additional video player plug-in to preview the
local screen on the web interface.
The web interface supports Google Chrome, Firefox, IE, Safari, Opera, 360, QQ
and other browsers, adaptability is very good.
-
Login
Run browser, input IP address (defaulted IP address is 192.168.1.188), to enter login interface, can select Language (Chinese or English), input admin and password to login as following: (Default Username: admin -
Real-time Preview:
The preview interface is shown above. On the right side.with options to control camera pan, tilt, zoom, focus, focus mode, pan ti lt speed, focus speed, zoom speed, preset position control, etc. At the bottom of the image, you can select the volume switch and vol ume level, as well as the full-size view and picture-in-picture mode. -
Parameter Setting
-
Click “Setting” to enter into parameter setting interface as following:
-
“Video Encode”: can set image encode mode, main stream and sub stream resolution/bit rate/frame rate, bit rate control way, and I frame interval etc as above image.
-
“video Transmission”: RTMP and NDI settings are available, as shown in the following figure:
-
“Audio Settings” : the audio enable can be off / on, the encoding mode can be selected, and the parameters such as sampling rate and bit rate can be adjusted, as shown in the following figure:
-
“Image Parameter” can set focus, exposure, white balance, image, image quality, noise-reduction, as following picture.
-
Focus including focus mode, default focal distance, digital zoom etc
-
Exposure includes exposure mode, shutter speed, gain, iris, brightness, and anti-flicker.
-
White Balance includes white balance mode, red gain, blue gain.
-
Image includes mirror, flip, backlight compensation, Gamma, WDR(wide dynamic range).
-
Image Quality includes brightness, sharpness, contrast, saturation.
-
Noise reduction includes 2D/3D reduction. There is on/off option for 2D, and off/auto/1~4 six options.
-
“Ethernet” includes DHCP mode, IP address, Net mask, Gateway, HTTP Port, RTSP Port, Visca Over IP. Default parameter as following:
DHCP| OFF| Gateway| 192.168.1.1| RTSP Port| 554
---|---|---|---|---|---
IP address| 192.168.1.188| DNS| 192.168.1.1| RTSP Encrypt| ON
Netmask| 255.255.255.0| HTTP Port| 80| Visca Over IP| 52381 -
“Firmware upgrade”: it is for camera program upgrade, currently only for ISP part update. How to update:
-
As following picture, click “clicking to upload file” icon, open dialog box, select to open the file, and click “upgrade” to start. DO NOT power off or do other operation when upgrading, reboot the camera after 5 min when upgrade finished.
-
Then login web end to select “reset all” to reset the camera completely.
-
Reset to default: reset the camera to default setting
-
Reset simply: reset camera image parameter
-
Reset Completelyall: reset camera Ethernet and image parameter, language and protocol will not be reset.
-
Reboot: Reboot ISP part of camera
-
Account Setting: is used for setting camera account and password
-
Input the account firstly, then input same password twice, click set to finish
-
Please remember account and password, otherwise you may be not able to login.
-
System Time: Set the time zone and NTP enable.
-
VIEW RTSP VIDEO VIA VLC
-
Default RTSP main streaming address: rtsp://192.168.1.188/stream/main
-
Default RTSP sub streaming address: rtsp://192.168.1.188/stream/sub
-
Default RTMP main streaming address: rtmp://192.168.1.188:1935/app/rtmpstream0 Default RTMP sub streaming address: rtmp://192.168.1.188:1935/app/rtmpstream1
-
Run VLC Media Player.
-
Media->network stream, to enter into “open media” interface.
-
Input RTSP address in URL as following:
-
Click play to view the real time image.
Note: If there is much image lag, select “more option” to enter into following setting, change buffer time smaller (VLC default buffer time is 1000ms).
-
NewTek Tools Guide
-
Image Preview
-
Download the NewTek NDI Tools via https://ndi.tv/tools/ and install it.
-
Find out the NDI 4.5 Tools/Studio Monitor via Windows toolbars, and then open it, as bellow:
-
Right click on the Studio Monitor screen, select the preview device:
-
-
Pan Tilt Control
Refer to above picture, once open the video via Studio Monitor, it will show up the control panel on the right side, to control camera pan, tilt, zoom, focus, preset, focus. -
Run WEB via Studio Monitor
Refer to above picture, once open the video via Studio Monitor, there will show up a setting icon at the lower right corner, single click this iron to enter WEB UI. -
How to use NDI tools to Virtual Input CAMERA
-
find out the NDI 4.5 Tools/Virtual Input via Windows toolbars, open it, then it will show up the NDI Virtual Input icon at the Windows toolbars, as bellow picture shows:
-
Right click on the NDI Virtual Input icon, to select the virtual device name:
-
Take Zoom for example, select NewTek NDI Video as video camera, as bellow picture shows:
This also work for other applications, such as GotoMeeting,Skype for Business, Hangouts.
-
VISCA OVER IP
VISCA over IP means VISCA protocol transmit via IP, to reduce RS232/RS485
cable layout (the controller must support IP communication function)
Communication port spec:
- Control port: RJ45 Gigabit LAN
- IP protocol : IPv4
- Transmit protocol: UDP
- IP address: set via web end or OSD menu
- Port address: 52381
- Confirm send/transmission control: depend on applied program
- Applied range: in the same segment, not suitable for bridge network
- Turn on camera: In the menu, set VISCA option to OVER IP
How to use VISCA over
-
IP VISCA Command
- It means commands from controller to peripheral equipment, when peripheral equipment receives commands, then return ACK.
- When commands executed, will return complete message.
- For different commands, camera will return different message.
-
VISCA Inquiry
It means inquiry from controller to peripheral equipment when peripheral equipment receives this kind of commands, it will return required message. -
VISCA Reply
It means ACK, complete message, reply or error reply, it is sent from peripheral equipment to controller.
Command format: the following is message head and valid message format.
Payload type:
Data definition as following:
Name | Value (Byte 0) | Value (Byte 0) | Value (Byte 0) |
---|---|---|---|
VISCA command | 0x01 | 0x00 | Stores the VISCA command. |
VISCA inquiry | 0x01 | 0x10 | Stores the VISCA inquiry. |
VISCA reply | 0x01 | 0x11 | Stores the reply for the VISCA command and VISCA |
inquiry, or VISCA device setting command.
VISCA device
setting command
| 0x01| 0x20| Stores the VISCA device setting command.
Control command| 0x02| 0x00| Stores the control command.
Control reply| 0x02| 0x01| Stores the reply for the control command.
Payload length
- Valid data length in Payload (1~16), is command length.
- For example, when valid data length is 16 byte
- Byte 2 : 0x00
- Byte 3 : 0x10
- Controller will save sequence number of each command, when one command sent, the sequence number of the command will add 1, when the sequence number becomes the max value, it will change to 0 for next time. The peripheral equipment will save sequenc e numbe r of each command, and return the sequence number to the controller.
Payload
According to Payload type, the following data will be saved.
-
VISCA command
Save VISCA command packet -
VISCA inquiry
Save VISCA message packet -
VISCA reply
Save VISCA return packet -
VISCA device setting command
Save VISCA equipment setting command packet. -
Control command
The following data is saved in control command payload Name| Value| Description
---|---|---
RESET| 0x01| Resets the sequence number to 0.
The value that was set as the sequence number is ignored.
ERROR| 0x0Fyy| yy=01:Abnormality in the
sequence number.
yy=02:Abnormality in the
message(message type).
- Controlled reply
The following data is saved in return command payload of control command. Message| Value| Description
---|---|---
ACK| 0x01| Reply for RESET.
Delivery confirmation
- VISCA over IP uses UDP as transmission communication protocol, UDP communication message transmission is not stable, it is necessary to confirm delivery and resent in application.
- Generally, when controller sends a command to peripheral equipment, controller will wait for the return message then send the next command, we can detect and confirm if the peripheral equipment receive the commands from return message’s lag time. If controller shows it is overtime, it is regarded as error transmission.
- If controller shows it is overtime, resend the commands to check peripheral’s status, resent command sequence number is same as last command, the following chart list the received message and status after resending the commands.
Lost message| Recelved message
for retransmission
| Status after
retransmission
| Correspondence after retransmission
---|---|---|---
Command| ACK message| Command is performed by retransmission.| Continue
processing.
Completion message For the command| ERROR(Abnormality in the sequence
number.)| Command has been performed.
If only the ACK message is
lost, the completion message returns.
| If the result by the completion message is needed, retransmit by updating
the sequence number.
Completion message for the command| ERROR(Abnormality in the sequence
number.)| Command has been performed.| If the result by the completion message
is needed, retransmit by updating the sequence number.
Inquiry| Reply message| Inquiry is performed by retransmission.| Continue
processing.
Reply message for the inquiry| ERROR(Abnormality in the sequence number.)|
Inquiry has been performed.| If the result by the reply message is needed,
retransmit by updating the sequence number.
Error message| Error message| Command is not performed. If the error cause
eliminates,
normal reply is return(ACK, reply message)
| Eliminate the error cause. If normal reply returns, continue processing.
Inquiry of the VISCA device setting command| Reply message of the VISCA device
setting command| Inquiry has been performed by retransmission.| Continue
processing.
Reply message of the
VISCA device setting command
| ERROR(Abnormality in the sequence number.)| Inquiry has been performed.| If the result by the reply message is needed, retransmit by updating the sequence number.
Sequence chart as following
Note: Do not set IP address, sub net mask, gateway parameter in VISCA over IP
command, otherwise, it will cause network breaks off. Due to change these
parameter, network will be in off status.