Telycam J.BC.0205.0098 HD PTZ Camera User Manual

July 26, 2024
Telycam

Telycam J.BC.0205.0098 HD PTZ Camera

Product Specifications

  • Part Number:
    • Drive+ SE 20X-SDI
    • Drive+ SE 20X-HDMI
  • Video Format:
    • SDI: 19201080P60/50/30/25/59.94/29.97/24, 19201080i60/50/59.94, 1280*720P60/50/30/25/59.94/29.97
    • HDMI: 19201080P60/50/30/25/59.94/29.97/24, 19201080i60/50/59.94, 1280*720P60/50/30/25/59.94/29.97
    • USB: 19201080P60/50/30/25(USB3.0), 1280720P60/50/30(USB3.0), etc.
  • Video Interface: SDI, NDI|HX, USB3.0 (for Drive+ SE 20X-SDI)
  • Sensor: 1/2.8 2.4MP CMOS sensor
  • Control Port: RS232 control port (input/output), HDMI port, 3G-SDI port, USB3.0 port, NDI|HX port, DC12V plug
  • Network Speed, Video encode Bit Rate Control, Video Bit Rate, Supported Protocol
  • POE+, NDI Daisy Chain, Minimum Lux, White Balance, Exposure, Focus, Iris, Electric Shutter, Gamma, WDR, BLC, etc.
  • Pan Tilt Flip, Input Voltage, Dimension, Net Weight

Product Usage Instructions

Safety Guides:

  1. Never move the camera manually when it is working.
  2. Put the camera on a fixed and smooth desk or platform to avoid leaned installation.
  3. Power Supply Polarity should be as per the provided drawing.

Packing List:
Quick Start:

  1. Check all cable connections before powering on.
  2. Dial Switch Setting (at the bottom of the camera):

Camera Interface:

  • Camera Lens
  • Camera Base
  • IR Receiver Panel
  • Power Indicator Light
  • Dial Switch
  • Tripod Screw Hole
  • HDMI port (optional)
  • 3G-SDI port (optional)
  • USB3.0 port
  • NDI|HX port
  • DC12V plug

IR Remote Controller:

  • Address Setting: Set camera address by long-pressing SET 1~SET4 until the key light turns on.
  • Camera Selection: Short press CAM1~CAM4 to select the relative camera.
  • Preset Setting : Long press number key (1-9) to set preset; short press to run preset.
  • Clear Preset : Long press CLR PRE to clear all presets.
  • Focus Key : Manual focus (valid under manual focus mode).
  • Zoom Key: Set the zoom rate.
  • Navigate Key : UP/DOWN/LEFT/RIGHT to adjust pan tilt and select menu.
  • OK/Home Key: Short press OK to return the camera to HOME position and confirm selections in OSD.

Frequently Asked Questions (FAQ)

  • Can I manually move the camera while it is working?
    No, never move the camera manually when it is working to avoid damage to the mechanism.

  • How should I set the camera on a desk or platform?
    Ensure the camera is placed on a fixed and smooth surface to prevent leaning during installation.

  • What should I check before powering on the camera?
    Check all cable connections to ensure proper setup before powering on the camera.

SAFETY GUIDES

  1. Before operation, please fully read and follow all instructions in the manual. For your safety, always keep this manual with the camera.
  2. The camera power input range is 100 240V AC(50 60Hz),ensure the power supply input within this rate before powering on.
  3. The camera power voltage is 12V DC, rated currency is 2A. We suggest you use it with the original power supply adapter supplied by the factory.
  4. Please keep the power cable, video cable and control cable in a safe place. Protect all cables especially the connectors.
  5. Operational environment: 0℃ 50℃, humidity less than 90%.To avoid any danger, do not put anything inside the camera, and keep away from the corrosive liquid.
  6. Avoid stress, vibration and damp during transportation, storage and installation.
  7. Do not detect the camera housing and cover. For any service, please contact authorized technicians.
  8. Video cable and control cable should be individually shielded, and cannot be substituted with other cables. Do not direct the camera lens towards strong light, such as the sun or the intensive light.
  9. Use a dry and soft cloth to clean the camera housing. Applied with neutral cleaning agent when there is need to clean. To avoid damage on the camera lens, never use strong or abrasive cleaning agents on the camera housing.
  10. Do not move the camera by holding the camera head. To avoid mechanical trouble, do not rotate the camera head by hand. NEVER MOVE THE CAMERA MANUALLY WHEN IT IS WORKING.
  11. Put the camera on fixed and smooth desk or platform, avoid leaned installation.
  12. Power Supply Polarity (Drawing)

Note:

  * The video quality may be affected by the specific frequencies of electromagnetic field.
  * Never grasp the head of the camera, and never move the camera by hand when it is working, otherwise, mechanism maybe destroyed.

PACKING LIST

Check all bellow items when open the package:

  • Camera 1
  • Power Adapter 1
  • Power Cable 1
  • RS232 Control Cable 1
  • USB3.0 Cable 1
  • Remote Controller 1
  • User Manual 1
  • Double sided Adhesive 1
  • QC certification 1

QUICK START

  1. Check all cable connections before power on.

  2. Dial Switch Setting (at the bottom of the camera):

Dial Switch (ARM)

 | SW-1| SW-2| Instruction
1| OFF| OFF| Updating mode
2| ON| OFF| Debugging mode
3| OFF| ON| Undefined
4| ON| ON| Working mode
Dial Switch

 | SW-3| SW-4| Instruction
1| OFF| OFF| reserve
2| ON| OFF| reserve
3| OFF| ON| reserve
4| ON| ON| reserve
Dial Switch (USB)

 | SW-5| SW-6| Instruction
1| OFF| OFF| Updating mode
2| ON| OFF| Working mode
3| OFF| ON| Undefined
4| ON| ON| Undefined

PRODUCT HIGHLIGHTS

  • Adopts most advanced ISP, 1/2.8 inch 2.4 MP sensor, providing 1080P60 full HD video resolution.
  • Big optical lens: 20x optical zoom , with 60 degree field of view.
  • 1080p60 video over IP, H.264, H.265 encoding.
  • Support NewTek NDI video transmission and control.
  • NDI|HX, HDMI or 3G SDI )), USB outputs, fit for different
  • White Balance, Exposure, Focus, Iris can be adjusted automatically or manually.
  • Support POE: one single CAT5/6 to get video, control and power supply.
  • Special Focusing Algorithm: fast and precise focusing performance when zooming or moving.
  • Smooth PTZ mechanical design, accurate pan tilt motor control.
  • 128 presets supported; Exposure parameter and white balance parameter can be saved in presets (in manual mode).
  • Standard Sony VISCA, IP VISCA, PELCO P, PELCO D control protocol; IP VISCA over both TCP and UDP.
  • Daisy chain supported, max 7 cameras connected in VISCA protocol.
  • Image flip function, support upside down installation.
  • Fast video format switch: less than 3 seconds.
  • Supported field upgrade for ISP, ARM, FPGA and USB.
  • USB3.0 port compatible with USB2.0 output.
  • Support RS232/RS485/UVC control.
  • Standard UVC1.5 protocol, seamlessly compatible with major video conferencing software and platform.
  • OSD menu in English and Chinese supported. IP address, streaming resolution and size can be set in OSD menu.

CAMERA SPEC

Camera Drive+ SE 20X-SDI Drive+ SE 20X-HDMI
Part Number TLC-300-IP-20(NDI)-SDI TLC-300-IP-20(NDI)-HDMI
  SDI: HDMI:
  1920*1080P60/50/30/25/59.94/29.97/24 1920*1080P60/50/30/25/59.94/29.97/24
  1920*1080i60/50/59.94 1920*1080i60/50/59.94
  1280*720P60/50/30/25/59.94/29.97 1280*720P60/50/30/25/59.94/29.97
  ****

USB:

 | 19201080P60/50/30/25(USB3.0); 1280720P60/50/30(USB3.0)
Video Format| 1280720P25(USB3.0&USB2.0); 1024576P30(USB3.0&USB2.0)
 | 960540P30(USB2.0); 640360P30(USB2.0); 512288P30(USB2.0)
 | IP:
 | Main Stream: 1920
1080@3~60; 1280720@3~60; 1024576@3~60
 | Sub Stream: 1280720@3~60; 1024576@3~60; 640360@3~60
 | NDI:
 | 1920
1080@3~60, 1280720@3~60, 1024576@3~60,
 | 640*360@3~60 (low bandwidth mode)
Video Interface| SDI, NDI|HX, USB3.0| HDMI, NDI|HX, USB3.0
Sensor| 1/2.8”2.4MP CMOS sensor
Zoom| f 4.9~98mm(20X), F1.5- 3.0, View Angle: 60°(Far)-3.2°(Near)
Rotation Angle| Pan: -170° ~ +170°;| Tilt: -30° ~ +90°
Rotation Speed| Pan: 0°~120°/s ;| Tilt: 0°~80°/s
Preset:| Remote controller: 10; RS232: 128; Accuracy: 0.1°
Control Port| RS232, RS485, NDI|HX(VISCA over IP), USB3.0(UVC1.5), USB2.0(UVC1.1)
---|---
Network Speed| 1000M
Video encode| H.264/H.265
Bit Rate Control| Variable Bit Rate, Constant Bit Rate
Video Bit Rate| 1024Kbps~16384Kbps


Supported Protocol

| TCP/IP, HTTP, RTSP, DHCP ,RTMP, Onvif, NDI(V4.5),


VISCA over IP(TCP&UDP), HTML5, VISCA, PELCO P/D

POE+| Supported
NDI| Supported
Daisy Chain| Support RS232 serial daisy chain
Minimum Lux| 0.1lux
White Balance| ATW/Manual/Auto/Indoor/Outdoor/Push
Exposure| Auto/Manual/Shutter/Iris/Bright
Focus| Auto/Manual
Iris| Auto/Manual
Electric Shutter| Auto/Manual
Gamma| Supported
WDR| Supported
BLC| Supported
2D Noise Reduction| Supported
3D Noise Reduction| Supported
Anti Flicker| OFF/50Hz/60Hz
Pan Tilt Flip| Supported
Input Voltage| DC12V/POE+(IEEE802.3at)
Dimension| 220mm×190mm×173mm
Net Weight| 1.35kg

CAMERA INTERFACE

  1. Camera Lens
  2. Camera Base
  3. IR Receiver Panel
  4. Power Indicator Light
  5. Dial Switch
  6. Tripod Screw Hole
  7. Installation Hole
  8. RS232 control port (input)
  9. RS232 control port(output)
  10. HDMI port
  11. 3G SDI port
  12. USB3.0 port
  13. NDI|HX port
  14. DC12V plug

CAMERA DIMENSION (MM)

IR REMOTE CONTROLLER

  • POWER

    • Under normal working mode, short press POWER key, to enter standby mode
    • Press it again, the camera will do self configuration, then go back to HOME position.
    • It will go to preset position if power on model has been set before.
  • FREEZE
    Not Supported in USB Short press FREEZE key to freeze/ unfreeze the image.

  • IRT (IR Transfer/IR Pass)
    Open / close the IR pass function. Once press the IRT key, the camera will receive and Pass the IR remote control signal to the codec/terminal (via VISCA IN port).

  • SET 1~SET4 ADDRESS SETTING
    Long press for 3seconds until the key light ON, to set camera address.

  • CAM1~CAM4 CAMERA SELECTING
    Short press to select the relative camera.

  • NUMBER KEY 1 9

    • Set preset: long press (3 seconds) the number key to set preset.
    • Run preset: Short press the number key to run preset.
  • CLR PRE CLEAR PRESET

    • CLR PRE+ number key: to clear the relative preset.
    • Long press to clear all preset.
  • FOCUS KEY ( ON THE LEFT)
    Manual focus, only valid under manual focus model.

  • ZOOM KEY( ON THE RIGHT SIDE)
    Set the zoom rate.

  • NAVIGATE KEY: UP/DOWN/LEFT/RIGHT
    Under working mode, use navigate key to set the pan tilt, and select menu when enter OSD.

  • OK /HOME KEY
    Under working mode, short press OK to make the camera go back to HOME position; and confirm the selection when enter OSD.

  • AF: Auto Focus.

  • MF: Manual Focus.

  • RESET: Press 3 seconds to reset camera.

  • MENU: Enter OSD menu.

  • LEARN+LIMIT L key: Set the pan tilt left limit position.

  • LEARN+LIMIT R key: Set the pan tilt right limit position.

  • LEARN+LMT CLR key: Clear the limit position.

  • BLC OFF/ BLC ON: Not Available.

  • BRIGHT-/BRIGHT+: Set image brightness, only valid under bright priority exposure mode.

  • Video Format Keys:
    Long press 3 seconds to select different video format output.

VISCA IN (RS232 PORT)

No. V_IN V_OUT   VISCA IN RS485
1 DTR DTR 1
2 DSR DSR 2
3 TXD TXD 3
4 GND GND 4
5 RXD RXD 5
6 A   6 A(+)
7 IR OUT   7 IR OUT
8 B   8 B(-)

VISCA IN &Mini DIN Connection 

Camera VISCA IN Mini DIN
1 DTR
2 DSR
3 TXD
4 GND
5 RXD
6 A(+)
7 IR OUT
8 B(-)

VISCA IN & DB9 Connection 

Camera VISCA IN Windows DB-9
1 DTR
2 DSR
3 TXD
4 GND
5 RXD
6 A(+)
7 IR OUT
8 B(-)

VISCA Network Construction:

SERIAL PORT CONFIGURATION

Parameter Value Parameter Value
Baud rate 2400/4800/9600/115200 Stop Bit 1bit
--- --- --- ---
Start Bit 1 bit Check Bit None
Date Bit 8 bit  

VISCA PROTOCOL

Part1 Camera Return Command

Ack/Completion Message

 | Command Packet| Note
ACK| z0 41 FF| Returned when the command is accepted.
Completion| z0 51 FF| Returned when the command has been executed.
Error Messages

 | Command Packet| Note
Syntax Error| z0 60 02 FF| Returned when the command format is different or when a command with illegal command parameters is accepted
Command Not Executable|

z0 61 41 FF

| Returned when a command cannot be executed due to current conditions. For example, when commands controlling the focus manually are received during auto focus.

Part 2 Camera Control Command

Command type| function| command|
---|---|---|---
Address Set| Broadcast| 88 30 01 FF| Address setting
IF_Clear| Broadcast| 88 01 00 01 FF| I/F Clear
Command Cancel|  | 8x 21 FF|


CAM_Power

| On| 8x 01 04 00 02 FF| ****

Power ON/OFF

Off| 8x 01 04 00 03 FF







CAM_Zoom

| Stop| 8x 01 04 07 00 FF|
Tele(Standard)| 8x 01 04 07 02 FF
Wide(Standard)| 8x 01 04 07 03 FF
Tele(Variable)| 8x 01 04 07 2p FF| ****

p = 0(low)~7(high)

Wide(Variable)| 8x 01 04 07 3p FF
Direct| 8x 01 04 47 0p 0q 0r 0s FF| pqrs: Zoom Position     (0(wide)

~0x4000(tele))


Direct with speed

| ****

8x 0A 04 47 0t 0p 0q 0r 0s FF

| t: spd  0~7

pqrs: Zoom Position     (0(wide)

~0x4000(tele))


CAM_DZoom

| ON| 8x 01 04 06 02 FF|
OFF| 8x 01 04 06 03 FF
 | Combine Mode| 8x 01 04 36 00 FF| Combine with optical zoom control
---|---|---|---
Separate Mode| 8x 01 04 36 01 FF| Separate with optical zoom control
Stop| 8x 01 04 06 00 FF| Enable In separate mode
Tele (Variable)| 8x 01 04 06 2p FF| Enable In separate mode
Wide (Variable)| 8x 01 04 06 3p FF| Enable In separate mode
Direct| 8x 01 04 46 0p 0q 0r 0s FF| Enable In separate mode











CAM_Focus

| Stop| 8x 01 04 08 00 FF|
Far(Standard)| 8x 01 04 08 02 FF
Near(Standard)| 8x 01 04 08 03 FF
Far (Variable)| 8x 01 04 08 2p FF| p=0 (Low) to 7 (High)
Near (Variable)| 8x 01 04 08 3p FF| p=0 (Low) to 7 (High)
Direct| 8x 01 04 48 0p 0q 0r 0s FF| pqrs: Focus Position
Auto Focus| 8x 01 04 38 02 FF|
Manual Focus| 8x 01 04 38 03 FF|
One Push AF| 8x 01 04 18 01 FF|


CAM_Zoom Focus

| ****

Direct

| 8x 01 04 47 0p 0q 0r 0s 0t 0u 0v 0w FF| pqrs: Zoom Position     (0(wide)~ 0x4000(tele))

tuvw: Focus Position








CAM_WB

| Auto| 8x 01 04 35 00 FF|
Indoor| 8x 01 04 35 01 FF|
Outdoor| 8x 01 04 35 02 FF|
One Push| 8x 01 04 35 03 FF|
ATW| 8x 01 04 35 04 FF|
Manual| 8x 01 04 35 05 FF|
Sodium lamp| 8x 01 04 35 08 FF|
fluorescent| 8x 01 04 35 09 FF|
One Push Trigger| 8x 01 04 10 05 FF|




CAM_R Gain

| Reset| 8x 01 04 03 00 FF| ****


Manual Control of R Gain

Up| 8x 01 04 03 02 FF
Down| 8x 01 04 03 03 FF
Direct| 8x 01 04 43 00 00 0p 0q FF| pq: R Gain  (0~0xFF)




CAM_B gain

| Reset| 8x 01 04 04 00 FF| ****


Manual Control of B Gain

Up| 8x 01 04 04 02 FF
Down| 8x 01 04 04 03 FF
Direct| 8x 01 04 44 00 00 0p 0q FF| pq: B Gain  (0-0xFF)
CAM_AE| Full Auto| 8×01 04 39 00 FF| Automatic Exposure mode
 | Manual| 8x 01 04 39 03 FF| Manual Control mode
---|---|---|---
Shutter Priority| 8x 01 04 39 0A FF| Shutter Priority

Automatic Exposure mode

Iris Priority| 8x 01 04 39 0B FF| Iris Priority Automatic

Exposure mode

Bright| 8x 01 04 39 0D FF| Bright Mode (Manual control)




CAM_Shutter

| Reset| 8x 01 04 0A 00 FF| ****


Shutter Setting

Up| 8x 01 04 0A 02 FF
Down| 8x 01 04 0A 03 FF
Direct| 8x 01 04 4A 00 00 0p 0q FF| pq: Shutter Position     (0~0x15)




CAM_Iris

| Reset| 8x 01 04 0B 00 FF| ****


Iris Setting(0~0xD)

Up| 8x 01 04 0B 02 FF
Down| 8x 01 04 0B 03 FF
Direct| 8x 01 04 4B 00 00 0p 0q FF| pq: Iris Position       (0~ 0x11)




CAM_Gain

| Reset| 8x 01 04 0C 00 FF| ****


Gain  Setting  (0~0x0F)

Up| 8x 01 04 0C 02 FF
Down| 8x 01 04 0C 03 FF
Direct| 8x 01 04 0C 00 00 0p 0q FF| pq: Gain Positon (0~0x0E)




CAM_Bright

| Reset| 8x 01 04 0D 00 FF| ****


Bright  Setting

Up| 8x 01 04 0D 02 FF
Down| 8x 01 04 0D 03 FF
Direct| 8x 01 04 4D 00 00 0p 0q FF| pq: Bright l Positon  (0~0x1B)



CAM_WDR

| On| 8x 01 04 3D 02 FF| ****

Exposure Compensation ON/OFF

Off| 8x 01 04 3D 03 FF
Direct| 8x 01 04 D3 pq FF| pq: ExpComp Position (0~0x6)


CAM_Back Light(BLC)

| On| 8x 01 04 33 02 FF| BackLight On
Off| 8x 01 04 33 03 FF| BackLight Off




CAM_Sharpness

| Reset| 8x 01 04 02 00 FF| ****


Aperture Control

Up| 8x 01 04 02 02 FF
Down| 8x 01 04 02 03 FF
Direct| 8x 01 04 42 00 00 0p 0q FF| pq: Aperture Gain (0~0x0F)



CAM_Memory(preset)

| Reset| 8x 01 04 3F 00 pp FF| ****

pp: Preset Number(=0 to 127) Corresponds to 0 to 9 on the Remote Commander

Set| 8x 01 04 3F 01 pp FF
Recall| 8x 01 04 3F 02 pp FF


CAM_LR_Reverse

| On| 8x 01 04 61 02 FF| ****

Image Flip Horizontal ON/OFF

Off| 8x 01 04 61 03 FF


CAM_Picture Flip

| On| 8x 01 04 66 02 FF| ****

Image Flip Vertical ON/OFF

---|---|---|---
Off| 8x 01 04 66 03 FF


CAM_RS485Ctl

| On| 8x 01 06 A5 02 FF|
Off| 8x 01 06 A5 03 FF
CAM_Saturation| Saturation| 8x 01 04 A1 00 00 0p 0q FF| pq:saturation level 0x00~0x0f
CAM_Contrast| Contrast| 8x 01 04 A2 00 00 0p 0q FF| pq:Contrast level 0x00~0x0f


CAM_Speed By Zoom

| On| 8x 01 06 A0 02 FF|
Off| 8x 01 06 A0 03 FF
CAM_PT Speed| PT Speed| 8x 01 04 C1 00 00 0p 0q FF| pq: PT speed  0x05~0x18
CAM_Zoom Speed| Zoom Speed| 8x 01 04 D1 00 00 0p 0q FF| pq: Zoom speed 0x01~0x07


CAM_Zoom Display

| On| 8x 01 06 C2 02 FF|
Off| 8x 01 06 C2 03 FF|
CAM_Freeze| Freeze| 8x 01 04 75 0p FF| p: Freeze switch 3=OFF, 2=ON
CAM_Preset Freeze Set| Preset Freeze Set| 8x 01 04 76 0p FF| p: Preset Freeze switch 3=OFF, 2=ON
CAM_Preset Speed Set| Preset Speed Set| 8x 01 7E 01 0B pp qq FF| pp: Preset NO.

qq: Preset Speed 2~24 default:15

CAM_Preset Speed Adj| Preset Speed Adj| 8x 01 7E 01 1B 0p FF| p: Adjustment of direction

3=down, 2=up

CAM_IR address| IR address| 8x 01 06 D8 0p FF| p:IR address  1~4
CAM_Gamma| Gamma set| 8x 01 04 5B 0p FF| P:Gamma NO. (0~4)
CAM_2D

Noise Reduction

| Direct| 8x 01 04 A5 0p FF| (0~0x01)
CAM_3D

Noise Reduction

| Direct| 8x 01 04 53 0p FF| (0~0x05)



FLICK

| 50HZ| 8x 01 04 23 01 FF|
60HZ| 8x 01 04 23 02 FF|
OFF| 8x 01 04 23 00 FF|








Video System Set(Factory)

|  | ****








8x 01 06 35 00 pp FF

| pp:     Video format

1080P60              0x00

1080P50              0x01

1080I60                0x02

1080I50               0x03

1080P30              0x04

1080P25              0x05

720P60                0x06

720P50                0x07

720P30                0x08

720P25                0x09

1080P5994          0x0E

1080I5994           0x0F

1080P2997          0x10

720P5994            0x13

720P2997            0x14

1080P24              0x11

1080P2398          0x12


Video System Set(Sony)

|  | ****

8x 01 04 24 72 0p 0q FF

| pq:     Video format

1080P60              0x2e

1080P50              0x2f

1080I60               0x01

 |  |  | 1080I50               0x04

1080P30              0x06

1080P25              0x08

720P60                0x09

720P50                0x0c

720P30                0x0e

720P25                0x11

1080P5994          0x13

1080I5994            0x02

1080P2997          0x07

720P5994            0x0a

720P2997            0x0f

1080P24              0x2a

1080P2398            0x2b

---|---|---|---
CAM_ID Write|  | 8x 01 04 22 0p 0q 0r 0s FF| pqrs: Camera ID (=0000 to FFFF)


DHCP control

| DHCP off| 8x 01 04 AE 00 FF| DHCP off
DHCP on| 8x 01 04 AE 01 FF| DHCP on



IP address control

| IP set| 8x 01 04 AB 0p 0q 0r 0s 0m 0n

0x 0y FF

| Set ip to :pq.rs.mn.xy
Mask set| 8x 01 04 AC 0p 0q 0r 0s 0m 0n

0x 0y FF

| Set mask to :pq.rs.mn.xy
Gateway set| 8x 01 04 AD 0p 0q 0r 0s 0m 0n

0x 0y FF

| Set gateway to : pq.rs.mn.xy








Mainstream

| ****

resolution

| ****

8x 01 04 C2 00 0p 0q 0r 0s 0m 0n 0x 0y FF

| pqrs : Column(x size) mnxy: Line (y size) only support:

19201080   1280720  1024*576

rate| 8x 01 04 C2 01 0p 0q 0r 0s 0m

0n 0x 0y FF

| pqrsmnxy: bitrate

(1024~16384kbps)


Encode Mode

| ****

8x 01 04 C2 02 0p 0q FF

| Mode sel:0xpq

0x00:h264

0x01:h265

Frame Rate| 8x 01 04 C2 03 0p 0q FF| Frame rate:0xpq (3~60)
IDR| 8x 01 04 C2 04 0p 0q FF| IDR Setting:0xpq (3~120)


Stream Rate Mode

| ****

8x 01 04 C2 05 0p 0q FF

| Contor mode:0xpq

0x00:CBR

0x01:VBR








Sub stream

| ****

resolution

| ****

8x 01 04 C3 00 0p 0q 0r 0s 0m 0n 0x 0y FF

| pqrs : Column(x size)

mnxy: Line  (y size)

only support: 640*360

rate| 8x 01 04 C3 01 0p 0q 0r 0s 0m 0n 0x 0y FF| pqrsmnxy: bitrate (1024~2048kbps)


Encode Mode

| ****

8x 01 04 C3 02 0p 0q FF

| Mode sel:0xpq

0x00:h264

0x01:h265

Frame Rate| 8x 01 04 C3 03 0p 0q FF| Frame rate:0xpq

(3~60)

IDR| 8x 01 04 C3 04 0p 0q FF| IDR Setting:0xpq

(3~120)


Stream Rate Mode

| ****

8x 01 04 C3 05 0p 0q FF

| Contor mode:0xpq

0x00:CBR

0x01:VBR




Color adjust

| Color adjust OFF| 8x 01 04 B6 00 FF| Color adjust off
Color adjust ON| 8x 01 04 B6 01 FF| Color adjust on
brightness balance

OFF

| 8x 01 04 B7 00 FF| Keep Brightness
brightness balance

ON

| 8x 01 04 B7 01 FF| No keep Brightness
 | Flare red| 8x 01 04 B8 dat FF| Flare mode red value

Default is 32

---|---|---|---
Flare green| 8x 01 04 B9 dat FF| Flare mode green value

Default is 32

Flare green| 8x 01 04 BA dat FF| Flare mode blue value

Default is 32




SYS_Menu

| Menu On| 8x 01 06 06 02 FF| Turn on the menu
Menu Off| 8x 01 06 06 03 FF| Turn off the menu
Menu Back| 8x 01 06 06 10 FF| Menu step back
Menu OK| 8x 01 7E 01 02 00 01 FF| Menu ok



IR_Receive

| On| 8x 01 06 08 02 FF| ****


IR(remote commander)receive ON/OFF

Off| 8x 01 06 08 03 FF
On/Off| 8x 01 06 08 10 FF




Cam_Tally

| ****



RGB

| ****



8x 01 7E 01 0A 00 0p FF

| P=0:       OFF

P=1:       RED

P=2:       GREEN

P=3:       RED&GREEN

P=4:       BLUE

P=5:       RED&BLUE P=6:       GREEN&BLUE

P=7:       RED&GREEN&BLUE












Pan_tilt Drive

| Up| 8x 01 06 01 VV WW 03 01 FF| ****









VV: Pan speed 0x01 (low speed) to 0x18 (high speed)

WW: Tilt speed 0x01 (low speed) to 0x14 (high speed)

YYYY: Pan Position(TBD) ZZZZ: Tilt Position(TBD)

Down| 8x 01 06 01 VV WW 03 02 FF
Left| 8x 01 06 01 VV WW 01 03 FF
Right| 8x 01 06 01 VV WW 02 03 FF
Up left| 8x 01 06 01 VV WW 01 01 FF
Up right| 8x 01 06 01 VV WW 02 01 FF
Down Left| 8x 01 06 01 VV WW 01 02 FF
Down Right| 8x 01 06 01 VV WW 02 02 FF
Stop| 8x 01 06 01 VV WW 03 03 FF
Absolute Position| 8x 01 06 02 VV WW

0Y 0Y 0Y 0Y 0Z 0Z 0Z 0Z FF

Relative Position| 8x 01 06 03 VV WW

0Y 0Y 0Y 0Y 0Z 0Z 0Z 0Z FF

Home| 8x 01 06 04 FF
Reset| 8x 01 06 05 FF


Pan-tilt Limit Set

| Set| 8x 01 06 07 00 0W

0Y 0Y 0Y 0Y 0Z 0Z 0Z 0Z FF

| W:1 Up Right 0:Down Left YYYY: Pan Limit Position(TBD) ZZZZ: Tilt Limit Position(TBD)
Clear| 8x 01 06 07 01 0W

07 0F 0F 0F 07 0F 0F 0F FF

Part 3 Camera Lnquiry Command

Command type command return note
CAM_Power Inq 8x 09 04 00 FF y0 50 02 FF On
y0 50 03 FF Off(Standby)
CAM_Zoom Pos Inq 8x 09 04 47 FF y0 50 0p 0q 0r 0s FF pqrs: Zoom Position
CAM_DZoom On Off Inq 8x 09 04 06 FF y0 50 0p FF p 2: ON 3: OFF
--- --- --- ---
CAM_DZoom Mode Inq 8x 09 04 36 FF y0 50 0p FF p 0:combination mode

1:separate mode
CAM_DZoom Posi Inq| 8x 09 04 46 FF| y0 50 0p 0q 0r 0s FF| pqrs: Zoom Position
CAM_Speed By Zoom Inq| 8x 09 06 A0 FF| y0 50 0p FF| p 2: ON 3: OFF
CAM_PT Speed Inq(IR)| 8x 09 04 C1 FF| y0 50 pp FF| pp: 0x05~0x18
CAM_Zoom Speed Inq(IR)| 8x 09 04 D1 FF| y0 50 0p FF| p:0x00~0x07
CAM_Focus Mode Inq| 8x 09 04 38 FF| y0 50 02 FF| Auto Focus
y0 50 03 FF| Manual Focus
CAM_Focus Pos Inq| 8x 09 04 48 FF| y0 50 0p 0q 0r 0s FF| pqrs: Focus Position
CAM_2D_Inq| 8x 09 04 A5 FF| y0 50 03 FF| (0~0x01)

p: 0: off        1: on


CAM_3D_Inq

| ****

8x 09 04 53 FF

| ****

y0 50 03 FF

| (0~0x05)

p:0:off          1: auto 2~5: noise level




CAM_WB Mode Inq

| ****



8x 09 04 35 FF

| y0 50 00 FF| Auto
y0 50 01 FF| Indoor mode
y0 50 02 FF| Outdoor mode
y0 50 03 FF| OnePush mode
y0 50 04 FF| ATW
y0 50 05 FF| Manual
CAM_RGain Inq| 8x 09 04 43 FF| y0 50 00 00 0p 0q FF| pq: R Gain
CAM_BGain Inq| 8x 09 04 44 FF| y0 50 00 00 0p 0q FF| pq: B Gain
CAM_Saturation Inq| 8x 09 04 A1 FF| y0 50 00 00 0p 0q FF| pq: saturation
CAM_Contrast Inq| 8x 09 04 A2 FF| y0 50 00 00 0p 0q FF| pq: contrast



CAM_AE Mode Inq

| ****


8x 09 04 39 FF

| y0 50 00 FF| Full Auto
y0 50 03 FF| Manual
y0 50 0A FF| Shutter priority
y0 50 0B FF| Iris priority
y0 50 0D FF| Bright


CAM_Flicker Mode Inq

| ****

8x 09 04 AA FF

| ****

y0 50 0p FF

| p  0: OFF

1: 50HZ

2: 60HZ

CAM_Shutter Pos Inq| 8x 09 04 4A FF| y0 50 00 00 0p 0q FF| pq: Shutter Position
CAM_Iris Pos Inq| 8x 09 04 4B FF| y0 50 00 00 0p 0q FF| pq: Iris Position
CAMGain Posi Inq| 8x 09 04 4C FF| y0 50 00 00 0p 0q FF| pq: Gain Position
CAM
Bright Posi Inq| 8x 09 04 4D FF| y0 50 00 00 0p 0q FF| pq: Bright Position
CAM_WDR Mode Inq| 8x 09 04 3D FF| y0 50 02 FF| On
y0 50 03 FF| Off
CAM_WDR Pos Inq| 8x 09 04 D3 FF| y0 50 0p FF| p: WDR Position
CAM_Aperture Inq| 8x 09 04 42 FF| y0 50 00 00 0p 0q FF| pq: Aperture Gain


CAM_Preset Exist Inq

| 8x 09 04 3F pp FF| ****

y0 50 0q FF

| pp: Memory number

q: 1=preset exist 0=preset not saved

SYS_Menu Mode Inq| 8x 09 06 06 FF| y0 50 02 FF| On
y0 50 03 FF| Off
CAM_LR_Reverse Inq| 8x 09 04 61 FF| y0 50 02 FF| On
y0 50 03 FF| Off
CAM_Picture Flip Inq| 8x 09 04 66 FF| y0 50 02 FF| On
y0 50 03 FF| Off
CAM_ID Inq| 8x 09 04 22 FF| y0 50 0p 0q 0r 0s FF| pqrs: Camera ID
CAM_DHCP Inq| 8x 09 04 AE FF| y0 50 pp FF|
CAM_IP Inq| 8x 09 04 AB FF| y0 50 0p 0p 0q 0q 0r 0r

0s 0s FF

|
CAM_MASK Inq| 8x 09 04 AC FF| y0 50 0p 0p 0q 0q 0r 0r

0s 0s FF

|
---|---|---|---
CAM_GATEWAY Inq| 8x 09 04 AD FF| y0 50 0p 0p 0q 0q 0r 0r

0s 0s FF

|
CAM_Flare Mode Inq| 8x 09 04 B6 FF| y0 50 pp FF|
CAM_Flare Bright Mode Inq| 8x 09 04 B7 FF| y0 50 pp FF|
CAM_Flare Red| 8x 09 04 B8 FF| y0 50 pp FF|
CAM_Flare Green| 8x 09 04 B9 FF| y0 50 pp FF|
CAM_Flare Blue| 8x 09 04 BA FF| y0 50 pp FF|
CAM_Version Inq| 8x 09 00 02 FF| y0 50 ab cd

mn pq rs tu vw FF

|
Video System Inq(Factory)| 8x 09 06 23 FF| y0 50 pp FF| pp: Video format
Video System Inq(Sony)| 8x 09 04 24 72

FF

| y0 50 0p 0p FF| pp: Video format
IR_Transfer| 8x 09 06 1A FF| y0 50 02 FF| On
y0 50 03 FF| Off
IR_Receive| 8x 09 06 08 FF| y0 50 02 FF| On
y0 50 03 FF| Off
Pan-tilt Max Speed Inq| 8x 09 06 11 FF| y0 50 ww zz FF| ww: Pan Max Speed zz: Tilt Max Speed
Pan-tilt Pos Inq| 8x 09 06 12 FF| y0 50 0w 0w 0w 0w

0z 0z 0z 0z FF

| wwww: Pan Position zzzz: Tilt Position



Mainstream Resolution Inq

| ****

8x 09 04 C2 00 FF

| ****

y0 50 0p 0q 0r 0s 0m 0n 0x 0y FF

| pqrs : Column(x size)

mnxy: Line (y size) only support: 1920*1080

1280*720

1024*576

Main stream Rate Inq| 8x 09 04 C2 01

FF

| y0 50 0p 0q 0r 0s 0m 0n

0x 0y FF

| pqrsmnxy: bitrate (1024~16384kbps)


Main Encode Mode Inq

| 8x 09 04 C2 02 FF| ****

y0 50 pp FF

| Mode sel:0xpp

0x00:h264

0x01: h265

Main Frame Rate Inq| 8x 09 04 C2 03

FF

| y0 50 pp FF| Frame rate:0xpp

(3~60)

Main IDR Inq| 8x 09 04 C2 04

FF

| y0 50 pp FF| IDR Setting:0xpp

(3~120)


Main Stream Rate Mode Inq

| 8x 09 04 C2 05 FF| ****

y0 50 pp FF

| Contor mode:0xpp

0x00:CBR

0x01:VBR


Sub stream Resolution Inq

| ****

8x 09 04 C3 00 FF

| ****

y0 50 0p 0q 0r 0s 0m 0n 0x 0y FF

| pqrs : Column(x size)

mnxy: Line (y size) only support:

640*360

Sub stream Rate Inq| 8x 09 04 C3 01

FF

| y0 50 0p 0q 0r 0s 0m 0n

0x 0y FF

| pqrsmnxy: bitrate (1024~2048kbps)


Sub Encode Mode Inq

| 8x 09 04 C3 02 FF| ****

y0 50 pp FF

| Mode sel:0xpp

0x00:h264

0x01: h265

Sub Frame Rate Inq| 8x 09 04 C3 03

FF

| y0 50 pp FF| Frame rate:0xpp

(3~60)

Sub ID RInq| 8x 09 04 C3 04

FF

| y0 50 pp FF| IDR Setting:0xpp

(3~120)


Sub Stream Rate Mode Inq

| 8x 09 04 C3 05 FF| ****

y0 50 pp FF

| Contor mode:0xpp

0x00:CBR

0x01:VBR

VISCA PAN TILT ABSOLUTE POSITION VALUE

Pan Angle VISCA Value Tilt Angle VISCA Value
-170 0xF670 -30 0xFE50
-135 0xF868 0 0x0000
-90 0xFAF0 30 0x01B0
-45 0xFD78 60 0x0360
0 0x0000 90 0x510
45 0x0288  
90 0x0510  
135 0x0798  
170 0x0990  

VISCA PAN TILT SPEED VALUE

Pan(Degree/Second) Pan(Degree/Second))
0 0.3
1 1
2 1.5
3 2.2
4 2.4
5 2.6
6 2.8
7 3.0
8 3.2
9 3.4
10 3.8
11 4.5
12 6
13 9
14 15
15 19
16 25
17 32
18 38
19 45
20 58
21 75
22 88
23 105
24 120

PELCO-D Protocol Command List

Function| Byte1| Byte2| Byte3| Byte4| Byte5| Byte6| Byte7
---|---|---|---|---|---|---|---
Up| 0xFF| Address| 0x00| 0x08| Pan Speed| Tilt Speed| SUM
Down| 0xFF| Address| 0x00| 0x10| Pan Speed| Tilt Speed| SUM
Left| 0xFF| Address| 0x00| 0x04| Pan Speed| Tilt Speed| SUM
Right| 0xFF| Address| 0x00| 0x02| Pan Speed| Tilt Speed| SUM
Up left| 0xFF| Address| 0x00| 0x0C| Pan Speed| Tilt Speed| SUM
Up right| 0xFF| Address| 0x00| 0x0A| Pan Speed| Tilt Speed| SUM
Down Left| 0xFF| Address| 0x00| 0x14| Pan Speed| Tilt Speed| SUM
Down Right| 0xFF| Address| 0x00| 0x12| Pan Speed| Tilt Speed| SUM
Zoom In| 0xFF| Address| 0x00| 0x20| 0x00| 0x00| SUM
Zoom Out| 0xFF| Address| 0x00| 0x40| 0x00| 0x00| SUM
Focus Far| 0xFF| Address| 0x00| 0x80| 0x00| 0x00| SUM
Focus Near| 0xFF| Address| 0x01| 0x00| 0x00| 0x00| SUM
Set Preset| 0xFF| Address| 0x00| 0x03| 0x00| Preset ID| SUM
Stop| 0xFF| Address| 0x00| 0x00| Pan Speed| Tilt Speed| SUM
Clear Preset| 0Xff| Address| 0x00| 0x05| 0x00| Preset ID| SUM
Call Preset| 0Xff| Address| 0x00| 0x07| 0x00| Preset ID| SUM
Query Pan Position| 0Xff| Address| 0x00| 0x51| 0x00| 0x00| SUM
Query Pan Position Response| 0Xff| Address| 0x00| 0x59| Value High Byte| Value Low Byte| SUM
Query Tilt Position| 0Xff| Address| 0x00| 0x53| 0x00| 0x00| SUM
Query Tilt Position Response| 0Xff| Address| 0x00| 0x5B| Value High Byte| Value Low Byte| SUM
Query Zoom Position| 0Xff| Address| 0x00| 0x55| 0x00| 0x00| SUM
Query Zoom Position Response| 0Xff| Address| 0x00| 0x5D| Value High Byte| Value Low Byte| SUM

PELCO-P Protocol Command List

Function Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7 Byte8
Up 0Xa0 Address 0x00 0x08 Pan Speed Tilt Speed 0Xaf XOR
Down 0Xa0 Address 0x00 0x10 Pan Speed Tilt Speed 0Xaf XOR
Left 0Xa0 Address 0x00 0x04 Pan Speed Tilt Speed 0Xaf XOR
Right 0Xa0 Address 0x00 0x02 Pan Speed Tilt Speed 0Xaf XOR
Up left 0Xa0 Address 0x00 0x0C Pan Speed Tilt Speed 0Xaf XOR
Up right 0Xa0 Address 0x00 0x0A Pan Speed Tilt Speed 0Xaf XOR
Down Left 0Xa0 Address 0x00 0x14 Pan Speed Tilt Speed 0Xaf XOR
Down Right 0Xa0 Address 0x00 0x12 Pan Speed Tilt Speed 0Xaf XOR
Zoom In 0Xa0 Address 0x00 0x20 0x00 0x00 0Xaf XOR
Zoom Out 0Xa0 Address 0x00 0x40 0x00 0x00 0Xaf XOR
Focus Far 0Xa0 Address 0x00 0x80 0x00 0x00 0Xaf XOR
Focus Near 0Xa0 Address 0x01 0x00 0x00 0x00 0Xaf XOR
Stop 0Xa0 Address 0x00 0x00 Pan Speed Tilt Speed 0Xaf XOR
Set Preset 0xA0 Address 0x00 0x03 0x00 Preset ID 0xAF XOR
Clear Preset 0xA0 Address 0x00 0x05 0x00 Preset ID 0xAF XOR
Call Preset 0xA0 Address 0x00 0x07 0x00 Preset ID 0xAF XOR
Query Pan Position 0xA0 Address 0x00 0x51 0x00 0x00 0xAF XOR

Query Pan

Position Response

| ****

0xA0

| ****

Address

| ****

0x00

| ****

0x59

| Value High Byte| Value Low Byte| ****

0xAF

| ****

XOR

Query Tilt Position| 0xA0| Address| 0x00| 0x53| 0x00| 0x00| 0xAF| XOR
Query Tilt

Position Response

| ****

0xA0

| ****

Address

| ****

0x00

| ****

0x5B

| Value High Byte| Value Low Byte| ****

0xAF

| ****

XOR

Query Zoom Position| 0xA0| Address| 0x00| 0x55| 0x00| 0x00| 0xAF| XOR
Query Zoom Position

Response

| ****

0xA0

| ****

Address

| ****

0x00

| ****

0x5D

| Value High Byte| Value Low Byte| ****

0xAF

| ****

XOR

OSD MENU

  1. Under working mode, press the MENU key on the IR remote controller, to enter the OSD menu as bellow:

  2. After enter the main menu, use the navigate UP/DOWN key to select the main menu. Once been selected, the main menu will change to blue background, and the right side will show all sub menu options.

  3. Press the navigate RIGHT key to enter sub menu; use UP/DONW key to select the sub menu; use LEFT/RIGHT key to select parameter.

  4. Press the MENU key again to return to previous menu. Press the MENU key continuously to exit the OSD menu.

  5. OSD Menu Setting List

SYSTEM

| PROTOCOL| Optional item:VISCA、PLC.P、PLC.D| Default:VISCA
---|---|---|---
ADDRESS| VISCA:1~7              PLC.P/PLC.D:1~255| Default:1
BAUD RATE| Optional item:2400、4800、9600、115200| Default:9600
PTL LOCK| Protocol lock: once set, above protocol setting will be locked| Default:OFF
RS485| RS485 ON/OFF| Default:ON
VISCA| Optional Item: OVER ALL、OVER IP、OVER COM| Default:OVER ALL
LANGUAGE| Optional Item: Chinese、English| Default:English

EXPOSURE

| EXPOSURE

MODE

|

AUTO、MANUAL、SHUTTER、IRIS、BRIGHT

|

Default:AUTO

---|---|---|---

SHUTTER

| Shutter speed: 1/30~1/10000, only valid under MANUAL and

SHUTTER mode

|

Default:AUTO

IRIS

| Iris setting: CLOSE~F1.8, only valid under MANUAL and IRIS

mode

|

Default:AUTO

GAIN| Gain setting: 0dB~30dB , only valid under MANUAL mode| Default:AUTO
EBRIGHT| Bright setting: 0~27, only valid under BRIGHT priority mode.| Default:AUTO
BRIGHT| 0~15| Default:8
WD MODE| ON/OFF| Default:OFF
WD LEVEL| WDR Level| Default:1
BLC| ON/OFF| Default:OFF

IMAGE

|

WB MODE

| Optional:ATW、MANUAL、AUTO、INDOOR、OUTDOOR、 PUSH|

Default:ATW

---|---|---|---
R GAIN| Red gain level: 0~255, only valid under manual white balance mode| Default:AUTO
B GAIN| Blue gain level:0~255 , only valid under manual white balance mode| Default:AUTO
FLICK| Anti-Flicker setting:50/60HZ, to reduce the video flicker| Default:50HZ
DZOOM| ON/OFF| Default:OFF
FOCUS| Select focus mode| Default:AUTO

QUALITY

|

2D NR

| 2D noise reduction: the bigger value is, the less noise on image

is, the lower resolution is.

|

Default:OFF

---|---|---|---

3D NR

| 3D noise reduction: OFF/AUTO/0~4, the bigger value is, the less motion noise on image is. High value will cause image

smear.

|

Default:AUTO

SHARPNESS

| Sharpness setting: 0~15, the higher value is, edge of the image

will be sharpen

|

Default:3

CONTRAST| Set contrast level| Default:8
SATURATION| Set saturation.| Default:8
GAMMA| Select gamma level| Default:0

AF SENSITIVITY

|

Optional:LOW/NORMAL/HIGH

| Default:

NORMAL

PTZ

|

SPEEDBYZ

| Speed By Zoom: proportional speed, the bigger the zoom is, the

slower the speed is

|

Default:ON

---|---|---|---
FLIP.HOR| Flip horizontal| Default:OFF
FLIP VER| Flip vertical| Default:OFF
PT SPD| Pan Tilt speed| Default:18
ZOOM SPD| Zoom speed| Default:5
MENU MIR| Optional Item: NORMAL、MIRROR| Default:NORMAL
PRE FRZ| Open/Close Video Freeze when running presets| Default:OFF
PRE PTSPD| Preset head speed: 2~24| Default:15
PRE ZSPD| Preset zoom speed: 1~7| Default:5

FORMAT

| 1080P59.94| 1080P50|

After selecting the system, press OK to switch the system. If it is the currently selected system, it will not be activated

---|---|---|---
1080I59.94| 1080I50
1080P29.97| 1080P25
720P59.94| 720P50
720P29.97| 720P25
1080P60| 1080P30
720P60| 720P30
1080I60| 1080P24

IP

| DHCP| ON/OFF|

Using up/down/left/right navigation button to select item to set, and using number button to set parameter.

Press menu button to return.

---|---|---|---
IP| 192.168.001.188
MASK| 255.255.255.000
GW (Gateway)| 192.168.001.001
MAIN| Default:19201080
BITRATE| Default:04096k
SUB| Default:1280
720
BITRATE| Default:02048k

RESET

| SYS RESET| Reset communication parameter to default
---|---|---
CAM RESET| Reset camera parameter to default
PT RESET| Reset pan/tilt parameter to default
ALL RESET| Reset all parameter to default

INFO

| IR ADDR| Camera IR control address
---|---|---
USB| USB firmware version
CLIENT| Default client end protocol: VISCA
MODEL NO.| Model number
ARM VER| ARM firmware version
FPGA VER| FPGA firmware version
CAM VER| Camera version
RELEASE| Software release date

Set IP Address in Menu
In order to facilitate customer debugging, the camera has the support menu to set IP address. The specific methods are as follows:

  1. Press “MENU” to open the menu interface, select “network parameters” in the menu to call up the IP setting interface:

  2. Right click the remote control to enter the IP setting interface, and select the parameters to be set by using the navigation up and down keys, and then select the IP address, mask, gateway:

  3. Short press the number key to set the corresponding parameters. After setting the current parameters, press the “MENU” key again to complete the current parameter setting;

  4. To exit the menu, just press the “MENU” key again.

UVC CONTROL

  1. Only run the client software after the USB3.0 camera has completed self-configuration (the IR indicator in blue color and will not flash); otherwise may cause black video issue.
  2. Make sure the USB3.0 camera is recognized by the PC Device Manager.
  3. Make sure the interval of video format switching more than 3 seconds, otherwise black video maybe caused.
  4. Make sure the interval of control command sending from the server (via USB) to the camera no less than 250ms.
  5. Support standard UVC interface.
    PU_BRIGHTNESS_CONTROL| 81 01 04 4d 00 00 0p 0q FF
    ---|---
    PU_CONTRAST_CONTROL| 81 01 04 A2 00 00 0p 0q FF
    PU_SATURATION_CONTROL| 81 01 04 A1 00 00 0p 0q FF
    PU_SHARPNESS_CONTROL| 8x 01 04 42 00 00 0p 0q FF
    PU_GAMMA_CONTROL| 8x 01 04 5B 0p FF
    PU_WHITE_BALANCE_TEMPERATURE_CONTROL| 8x 01 04 35 0X FF
    PU_BACKLIGHT_COMPENSATION_CONTROL| 81 01 04 33 02/03 FF
    PU_POWER_LINE_FREQUENCY_CONTROL| 8x 01 04 AA 00/01/02 FF
    CT_ZOOM_ABSOLUTE_CONTROL| 8x 01 04 47 0p 0q 0r 0s FF
    CT_PANTILT_ABSOLUTE_CONTROL| 8x 01 06 02 VV WW 0Y 0Y 0Y 0Y 0Z 0Z 0Z 0Z F
    CT_PANTILT_RELATIVE_CONTROL| 8x 01 06 01 pp qq rr ss FF
    CT_ZOOM_RELATIVE_CONTROL| 8x 01 04 07 pp FF

WEB SETTING

It is not necessary to install additional video player plug-in to preview the local screen on the web interface.
The web interface supports Google Chrome, Firefox, IE, Safari, Opera, 360, QQ and other browsers, adaptability is very good.

  1. Login
    Run browser, input IP address (defaulted IP address is 192.168.1.188), to enter login interface, can select Language (Chinese or English), input admin and password to login as following: (Default Username: admin

  2. Real-time Preview:
    The preview interface is shown above. On the right side.with options to control camera pan, tilt, zoom, focus, focus mode, pan ti lt speed, focus speed, zoom speed, preset position control, etc. At the bottom of the image, you can select the volume switch and vol ume level, as well as the full-size view and picture-in-picture mode.

  3. Parameter Setting

    • Click “Setting” to enter into parameter setting interface as following:

    • “Video Encode”: can set image encode mode, main stream and sub stream resolution/bit rate/frame rate, bit rate control way, and I frame interval etc as above image.

    • “video Transmission”: RTMP and NDI settings are available, as shown in the following figure:

    • “Audio Settings” : the audio enable can be off / on, the encoding mode can be selected, and the parameters such as sampling rate and bit rate can be adjusted, as shown in the following figure:

    • “Image Parameter” can set focus, exposure, white balance, image, image quality, noise-reduction, as following picture.

    • Focus including focus mode, default focal distance, digital zoom etc

    • Exposure includes exposure mode, shutter speed, gain, iris, brightness, and anti-flicker.

    • White Balance includes white balance mode, red gain, blue gain.

    • Image includes mirror, flip, backlight compensation, Gamma, WDR(wide dynamic range).

    • Image Quality includes brightness, sharpness, contrast, saturation.

    • Noise reduction includes 2D/3D reduction. There is on/off option for 2D, and off/auto/1~4 six options.

    • “Ethernet” includes DHCP mode, IP address, Net mask, Gateway, HTTP Port, RTSP Port, Visca Over IP. Default parameter as following:
      DHCP| OFF| Gateway| 192.168.1.1| RTSP Port| 554
      ---|---|---|---|---|---
      IP address| 192.168.1.188| DNS| 192.168.1.1| RTSP Encrypt| ON
      Netmask| 255.255.255.0| HTTP Port| 80| Visca Over IP| 52381

    • “Firmware upgrade”: it is for camera program upgrade, currently only for ISP part update. How to update:

    • As following picture, click “clicking to upload file” icon, open dialog box, select to open the file, and click “upgrade” to start. DO NOT power off or do other operation when upgrading, reboot the camera after 5 min when upgrade finished.

    • Then login web end to select “reset all” to reset the camera completely.

    • Reset to default: reset the camera to default setting

    • Reset simply: reset camera image parameter

    • Reset Completelyall: reset camera Ethernet and image parameter, language and protocol will not be reset.

    • Reboot: Reboot ISP part of camera

    • Account Setting: is used for setting camera account and password

    • Input the account firstly, then input same password twice, click set to finish

    • Please remember account and password, otherwise you may be not able to login.

    • System Time: Set the time zone and NTP enable.

VIEW RTSP VIDEO VIA VLC

  • Default RTSP main streaming address: rtsp://192.168.1.188/stream/main

  • Default RTSP sub streaming address: rtsp://192.168.1.188/stream/sub

  • Default RTMP main streaming address: rtmp://192.168.1.188:1935/app/rtmpstream0 Default RTMP sub streaming address: rtmp://192.168.1.188:1935/app/rtmpstream1

    1. Run VLC Media Player.

    2. Media->network stream, to enter into “open media” interface.

    3. Input RTSP address in URL as following:

    4. Click play to view the real time image.
      Note: If there is much image lag, select “more option” to enter into following setting, change buffer time smaller (VLC default buffer time is 1000ms).

NewTek Tools Guide

  1. Image Preview

    • Download the NewTek NDI Tools via https://ndi.tv/tools/ and install it.

    • Find out the NDI 4.5 Tools/Studio Monitor via Windows toolbars, and then open it, as bellow:

    • Right click on the Studio Monitor screen, select the preview device:

  2. Pan Tilt Control
    Refer to above picture, once open the video via Studio Monitor, it will show up the control panel on the right side, to control camera pan, tilt, zoom, focus, preset, focus.

  3. Run WEB via Studio Monitor
    Refer to above picture, once open the video via Studio Monitor, there will show up a setting icon at the lower right corner, single click this iron to enter WEB UI.

  4. How to use NDI tools to Virtual Input CAMERA

    • find out the NDI 4.5 Tools/Virtual Input via Windows toolbars, open it, then it will show up the NDI Virtual Input icon at the Windows toolbars, as bellow picture shows:

    • Right click on the NDI Virtual Input icon, to select the virtual device name:

    • Take Zoom for example, select NewTek NDI Video as video camera, as bellow picture shows:
      This also work for other applications, such as GotoMeeting,Skype for Business, Hangouts.

VISCA OVER IP

VISCA over IP means VISCA protocol transmit via IP, to reduce RS232/RS485 cable layout (the controller must support IP communication function)
Communication port spec:

  • Control port: RJ45 Gigabit LAN
  • IP protocol : IPv4
  • Transmit protocol: UDP
  • IP address: set via web end or OSD menu
  • Port address: 52381
  • Confirm send/transmission control: depend on applied program
  • Applied range: in the same segment, not suitable for bridge network
  • Turn on camera: In the menu, set VISCA option to OVER IP

How to use VISCA over

  • IP VISCA Command

    • It means commands from controller to peripheral equipment, when peripheral equipment receives commands, then return ACK.
    • When commands executed, will return complete message.
    • For different commands, camera will return different message.
  • VISCA Inquiry
    It means inquiry from controller to peripheral equipment when peripheral equipment receives this kind of commands, it will return required message.

  • VISCA Reply
    It means ACK, complete message, reply or error reply, it is sent from peripheral equipment to controller.

Command format: the following is message head and valid message format.

Payload type:
Data definition as following:

Name Value (Byte 0) Value (Byte 0) Value (Byte 0)
VISCA command 0x01 0x00 Stores the VISCA command.
VISCA inquiry 0x01 0x10 Stores the VISCA inquiry.
VISCA reply 0x01 0x11 Stores the reply for the VISCA command and VISCA

inquiry, or VISCA device setting command.
VISCA device

setting command

| 0x01| 0x20| Stores the VISCA device setting command.
Control command| 0x02| 0x00| Stores the control command.
Control reply| 0x02| 0x01| Stores the reply for the control command.

Payload length

  • Valid data length in Payload (1~16), is command length.
  • For example, when valid data length is 16 byte
    • Byte 2 : 0x00
    • Byte 3 : 0x10
  • Controller will save sequence number of each command, when one command sent, the sequence number of the command will add 1, when the sequence number becomes the max value, it will change to 0 for next time. The peripheral equipment will save sequenc e numbe r of each command, and return the sequence number to the controller.

Payload
According to Payload type, the following data will be saved.

  • VISCA command
    Save VISCA command packet

  • VISCA inquiry
    Save VISCA message packet

  • VISCA reply
    Save VISCA return packet

  • VISCA device setting command
    Save VISCA equipment setting command packet.

  • Control command
    The following data is saved in control command payload Name| Value| Description
    ---|---|---
    RESET| 0x01| Resets the sequence number to 0.

The value that was set as the sequence number is ignored.

ERROR| 0x0Fyy| yy=01:Abnormality in the

sequence number.

yy=02:Abnormality in the

message(message type).

  • Controlled reply
    The following data is saved in return command payload of control command. Message| Value| Description
    ---|---|---
    ACK| 0x01| Reply for RESET.

Delivery confirmation

  • VISCA over IP uses UDP as transmission communication protocol, UDP communication message transmission is not stable, it is necessary to confirm delivery and resent in application.
  • Generally, when controller sends a command to peripheral equipment, controller will wait for the return message then send the next command, we can detect and confirm if the peripheral equipment receive the commands from return message’s lag time. If controller shows it is overtime, it is regarded as error transmission.
  • If controller shows it is overtime, resend the commands to check peripheral’s status, resent command sequence number is same as last command, the following chart list the received message and status after resending the commands.
    Lost message| Recelved message

for retransmission

| Status after

retransmission

| Correspondence after retransmission
---|---|---|---
Command| ACK message| Command is performed by retransmission.| Continue processing.
Completion message For the command| ERROR(Abnormality in the sequence number.)| Command has been performed.

If only the ACK message is

lost, the completion message returns.

| If the result by the completion message is needed, retransmit by updating the sequence number.
Completion message for the command| ERROR(Abnormality in the sequence number.)| Command has been performed.| If the result by the completion message is needed, retransmit by updating the sequence number.
Inquiry| Reply message| Inquiry is performed by retransmission.| Continue processing.
Reply message for the inquiry| ERROR(Abnormality in the sequence number.)| Inquiry has been performed.| If the result by the reply message is needed, retransmit by updating the sequence number.
Error message| Error message| Command is not performed. If the error cause eliminates,

normal reply is return(ACK, reply message)

| Eliminate the error cause. If normal reply returns, continue processing.
Inquiry of the VISCA device setting command| Reply message of the VISCA device setting command| Inquiry has been performed by retransmission.| Continue processing.
Reply message of the

VISCA device setting command

| ERROR(Abnormality in the sequence number.)| Inquiry has been performed.| If the result by the reply message is needed, retransmit by updating the sequence number.

Sequence chart as following
Note: Do not set IP address, sub net mask, gateway parameter in VISCA over IP command, otherwise, it will cause network breaks off. Due to change these parameter, network will be in off status.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals