BANNER BL60 Sealed LED Bar Light Instruction Manual

July 29, 2024
BANNER

BANNER BL60 Sealed LED Bar Light Instruction Manual

BANNER BL60 Sealed LED Bar Light Instruction Manual

Features

Sealed IP67, IP68, and IP69K lighting for use with Vision Systems in washdown environments To view or download the latest technical information about this product, including specifications, dimensions, accessories, and wiring, go to www.bannerengineering.com.

  • Four high-intensity, visible wavelengths, plus IR and UV
  • Oil, chemical, and water resistant with IP67, JIS C IP68G, and IP69K per DIN 40050-9
  • Available in 340 mm and 640 mm lengths
  • Highly resistant to vibration and shock
  • High-power, solid-state LED array; continuous or strobed operation
  • PNP and NPN strobe operation
  • Black e-coated aluminum housing

Model Key

BANNER BL60 Sealed LED Bar Light Instruction Manual - Model
Key

The following caution applies to white LED models and blue LED models:

⚠ CAUTION: Risk Group 2: Possibly hazardous optical radiation emitted from this product.
Do not stare at the operating lamp. May be harmful to the eyes. Risk Group 2 (RG 2) products generally do not pose a realistic optical hazard if aversion responses limit the exposure duration or where lengthy exposures are unrealistic.
– IEC 62471

The following caution applies to ultraviolet models:

⚠ CAUTION: Risk Group 2: UV Emitted from this product.
Eye or skin irritation may result from exposure. Use appropriate shielding and eye protection. Risk Group 2 (RG 2) products generally do not pose a realistic optical hazard if aversion responses limit the exposure duration or where lengthy exposures are unrealistic.
– IEC 62471

⚠ CAUTION: Risk Group 1: IR Emitted from this product.
Use appropriate shielding or eye protection. Risk Group 1 (RG 1) products are safe for most use applications, except for very prolonged exposures where direct ocular exposures may be expected.
– IEC 62471

Wiring

BANNER BL60 Sealed LED Bar Light Instruction Manual -
Wiring

Specifications

Supply Voltage
12 V DC to 30 V DC
Use only with a suitable Class 2 power supply (UL) or SELV power supply (CE)
See the electrical characteristics on the product label.

Supply Protection Circuitry
Protected against reverse polarity and transient voltages

Pulse Width Modulation (PWM)/Strobe Control
Maximum Frequency: 30 kHz
Minimum On Time: 20 μs
Input Delay Time: 5 μs
Input Voltage Threshold:
PNP: > 7 V DC
NPN: < 2 V DC
Input Current Maximum: 5 mA

Analog Control
Intensity Adjustment Range: 10% to 100%
Input Voltage Range: 1 V DC to 10 V DC
Input Current Maximum: 5 mA

Construction
Housing: Black e-coated aluminum housing
Window: Clear or diffuse polycarbonate window, or clear borosilicate glass window

Mounting
(6) M6×1 threaded holes in back; multiple bracket options available

Connections
Integral 5-pin M12 male quick-disconnect connector, accessory cordset required

LED Lifetime
Lumen Maintenance: L70
When operating within specifications, the output decreases
less than 30% after the following time periods:
Daylight White: 90,000 hours
Red: 70,000 hours
Green: 70,000 hours
Blue: 50,000 hours
Yellow: 60,000 hours
UV: 35,000 hours

Vibration and Mechanical Shock
Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55
Hz, 1.0 mm amplitude, 5 minutes sweep, 30 minutes dwell)
Meets IEC 60068-2-27 requirements (Shock: 15G 11 ms duration, half sine wave)

Operating Conditions
–40 °C to +50 °C (–40 °F to +122 °F)

Storage Temperature
–40 °C to +70 °C (–40 °F to +158 °F)

Environmental Rating
IP67, JIS C IP68G, IP69K per DIN 40050-9

Required Overcurrent Protection

⚠ WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations.

Overcurrent protection is required to be provided by end product application per the supplied table.
Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to www.bannerengineering.com.

Certification
BANNER BL60 Sealed LED Bar Light Instruction Manual -
Certification

Supply Current

BANNER BL60 Sealed LED Bar Light Instruction Manual - Supply
Current

FCC Part 15 Class B for Unintentional Radiators
(Part 15.105(b)) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

(Part 15.21) Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

Dimensions

BANNER BL60 Sealed LED Bar Light Instruction Manual -
Dimensions BANNER BL60
Sealed LED Bar Light Instruction Manual - Dimensions

Optical Data

Light Characteristic: Clear and Diffuse Window Values shown are typical at 25 °C.

BANNER BL60 Sealed LED Bar Light Instruction Manual - Optical
Data

Photometric Data

Optical data shown below is for daylight white and UV 365nm models only. To get lux/irradiance and candela/radiant intensity values for models with other colors, multiply the values shown on the charts by the following factors:

BANNER BL60 Sealed LED Bar Light Instruction Manual - Photometric
Data BANNER BL60 Sealed LED
Bar Light Instruction Manual - Photometric Data ![BANNER BL60 Sealed LED Bar Light Instruction Manual

Accessories

Cordsets

BANNER BL60 Sealed LED Bar Light Instruction Manual -
Cordsets BANNER BL60 Sealed LED Bar
Light Instruction Manual - Cordsets

Brackets

BANNER BL60 Sealed LED Bar Light Instruction Manual -
Brackets BANNER BL60 Sealed LED Bar
Light Instruction Manual - Brackets BANNER BL60 Sealed LED Bar Light Instruction Manual -
Brackets

Banner Engineering Corp Limited Warranty

Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.

THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.

This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.

Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com.
For patent information, see www.bannerengineering.com/patents.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals