Acuity Brands CSVT Vapor Tight LED Strip Light Owner’s Manual
- June 11, 2024
- Acuity Brands
Table of Contents
CSVT Vapor Tight LED Strip Light
Owner’s Manual
Capable Luminaire
This item is an A+ capable luminaire, which has been designed and tested to provide consistent color appearance and out-of-the-box control compatibility with simple commissioning.
- All configurations of this luminaire meet the Acuity Brands’ specification for chromatic consistency
- This luminaire is part of an A+ Certified solution for light® or Point™ Wireless control networks marked by a shaded background
To learn more about A+, visit www.acuitybrands.com/aplus. See ordering tree for details
FEATURES & SPECIFICATIONS
INTENDED USE — Ideal for damp/wet locations such as outdoor venues, canopies
and locker rooms. Not for use or installation in direct outdoor sunlight. Must
be installed under canopy or covered ceiling. For direct sunlight
installations, please refer to the FEX product family. Certain airborne
contaminants can diminish integrity of acrylic and/or polycarbonate. Click
here for Acrylic-Polycarbonate Compatibility table for suitable
uses.
Certain airborne contaminants may adversely affect the functioning of LEDs and
other electronic components, depending on various factors such as
concentrations of the contaminants, ventilation, and temperature at the end-
user location. Click here for a list of substances that may not be suitable
for interaction with LEDs and other electronic
components.
CONSTRUCTION
– Light Gray Polycarbonate housing
– Frosted Polycarbonate lens
– Poured in place polyurethane gasket
– Polycarbonate Latches, optional stainless steel latches available.
– Standard 1/2″ wet location fitting
ELECTRICAL
– High Efficiency LEDs meet DLC Standard
– MVOLT (120-277V) & 347V
– 0-10V Dimming standard
Luminaire Surge Protection Level: Designed to withstand up to 2.5kV/0.75kA per
ANSI C82.77-5-2015. For applications requiring higher level of protection
additional surge protection must be provided.
INSTALLATION
– Surface (wall, ceiling) using standard brackets
– Suspended (chain, cable) using standard brackets
LISTINGS
– CSA Certified to UL & C-UL Standards for wet location
– IP65, IP66 rated per IEC60529
– NSF Splash zone rated
– FCC Title 47, Part 15 Subpart B compliant
– 2.5kV/0.75kA Surge Rated per ANSI C82-77-5-2015
– CSA Ambient Listings on Page 3
– Lumen Maintenance Listed on Page 3
Design Lights Consortium® (DLC) qualified product. Not all versions of this
product may be DLC qualified. Please check the DLC Qualified Products List at
www.designlights.org/QPL to confirm which
versions are qualified.
WARRANTY — 5-year limited warranty. This is the only warranty provided and no
other statements in this specification sheet create any warranty of any kind.
All other express and implied warranties are disclaimed.
Complete warranty terms located at: www.acuitybrands.com/support/warranty
/terms-and-conditions Note: Actual performance may differ as a result of end-user
environment and application. All values are design or typical values, measured
under laboratory conditions at 25 °C. Specifications subject to change without
notice.
Looking for Contractor Select readily available configurations? Click here to
visit Contractor Select™ spec sheet or go to
www.contractorselect.com.
A+ Capable options indicated by this color background.
ORDERING INFORMATION
Lead times will vary depending on options selected. Consult with your sales
representative.
Example: CSVT L48 AL03 MVOLT SWW3 80CRI
Series| Length| Lumen Output| Voltage| Color
temperature| Color rendering index
---|---|---|---|---|---
CSVT Linear LED Vapor Tight| L48 48″| 3000LM
4000LM| 3,000 lumens ‡
4,000 lumens ‡| MVOLT 347 120-277V 347V| 35K
40K| 3500K ‡
4000K ‡| 80CRI 80 CRI
5000LM| 5,000 lumens ‡| 50K| 5000K ‡
6000LM| 6,000 lumens ‡| SWW3| Switchable white, 35K / 40K / 50K
ALO3| Switchable lumens, 3000LM / 4000LM / 5000LM|
L96 96″| 6000LM| 6,000 lumens ‡
8000LM| 8,000 lumens ‡
10000LM| 10,000 lumens ‡
12000LM| 12,000 lumens ‡
ALO4| Switchable lumens, 6000LM, 8000LM, and 10000LM
Options
STSL | Stainless steel latches |
---|---|
IE7WCP | Emergency battery pack, 7W, CA Title 20 Noncompliant ‡ |
IE7WCPHE | Emergency battery pack, 7W, Certified in CA Title 20 MAEDBS ‡ |
WLFEND2 | Wet location fitting (fittings out both ends) ‡ |
Individual Controls ‡
SBOR10 | 360° integral low mount motion sensor (standard on/off operation) |
---|---|
SBOR10 D 3V | 360° integral low mount motion sensor with dimming (low trim set |
at 30%)
SBOR10 P| 360° integral low mount motion sensor with photocell
Light Wireless Controls ‡
NLTAIR2 RSBOR10 light (wireless) gen 2 high mount occupancy & daylight sensor
NOTE: ‡ indicates option chosen has ordering restrictions. Please
reference ordering restrictions chart.
* Option Value Ordering Restrictions
Option value| Restriction
35K, 40K, 50K| Not available with ALO lumen packages.
3000LM, 4000LM, 5000LM, 6000LM, 8000LM, 10000LM, 12000LM| Not available with
SWW3.
CSVT STSL LATCH| Requires two for L96
IE7WCP, IE7WCPHE| Not available with 347V.
Individual Controls| Not available with WLFEND2 option.
nLight Wireless Controls| Not available with WLFEND2 option.
WLFEND2| Not available with cord set or sensor options.
Accessories: Order as separate catalog number.
CSVT STSL LATCH Stainless steel latch kit (Set of 10) ‡
How to Estimate Delivered Lumens in Emergency Mode
Use the formula below to estimate the delivered lumens in emergency mode
Delivered Lumens = 1.25 x P x LPW
P = Output power of emergency driver. P = 10W for IE10WCPHE
LPW = Lumen per watt rating of the luminaire. This information is available on
the ABL luminaire spec sheet. The LPW rating is also available at Design light
Consortium.
DIMENSIONS
All dimensions are shown in inches unless otherwise noted.
Length | Width | Height | Length | Approximate weight | Fixtures per pallet |
---|---|---|---|---|---|
L48 | 5.4 | 3.8 | 50.3 | 5 lbs | 70 |
L96 | 5.4 | 3.8 | 98.3 | 10 lbs | 70 |
*Weights will vary slightly with added options.
OPERATIONAL DATA
Length| Package| Voltage| Watts| 3500 K| 4000 K|
5000 K| Comparable Light source
---|---|---|---|---|---|---|---
Lumens| LPW| Lumens| LPW| Lumens| LPW
L48| 3000LM| MVOLT| 24| 3033| 125| 3106| 128| 3134| 129| 1-lamp 32W T8, 1-lamp
54W T5H0, 50W HID
347| 28| 108| 110| 11
4000LM| MVOLT| 34| 4065| 119| 4163| 122| 4200| 123| 2-lamp 32W18, 1-lamp 54W
T5H0, 50W HID
347| 40| 102| 105| 106
5000LM| MVOLT| 42| 4829| 115| 4946| 118| 4989| 119| 2-lamp 32W18, 1-lamp 54W
T5H0, 70W HID
347| 49| 99| 101| 102
60001M| MVOLT| 49| 6066| 125| 6213| 128| 6268| 129| 2 lamp 32W T8, 2-lamp 54W
T5H0, 100W HID
347| 56| 42| 110| 111
AL03 (3000LM)| MVOLT| 24| 3019| 124| 3106| 128| 3141| 129| 1-lamp 32W T8,
1-lamp 54W T5H0, 50W HID
347| 28| 107| 110| 111
AL03 (4000LM)| MVOLT| 34| 4046| 118| 4163| 122| 4210| 123| 2-lamp 32W T8,
1-lamp 54W T5H0, 50W HID
347| 40| 102| 105| 106
AL03 (5000LM)| MVOLT| 42| 4806| 114| 4946| 118| 5001| 119| 2-lamp 32W T8,
1-lamp 54W T5H0, 70W HID
347| 49| 98| 101| 102
L96| 60001M| MVOLT| 49| 6066| 125| 6213| 128| 6268| 129| 2-lamp 32W T8, 2-lamp
54W T5H0, 100W HID
347| 56| 108| 110| 111
8000LM| MVOLT| 68| 8130| 119| 8326| 122| 8400| 123| 3-lamp 32W18, 2-lamp 54W
T5H0, 100W HID
347| 80| 102| 105| 106
10000LM| MVOLT| 84| 9658| 115| 9891| 118| 9979| 119| 4 lamp 32W18, 2-lamp 54W
15H0, 150W HID
347| 98| 99| 101| 102
12000LM| MVOLT| 103| 12133| 118| 12425| 121| 12535| 122| 4 lamp 32W T8, 3-lamp
54W T5H0, 150W HID
347| 120| 101| 104| 105
AL04 (60001M)| MVOLT| 49| 6038| 124| 6213| 128| 6283| 129| 2 lamp 32W18,
2-lamp 54W T5H0, 100W HID
347| 56| 107| 110| 111
AL04 (8000LM)| MVOLT| 68| 8092| 118| 8326| 122| 8420| 123| 3 lamp 32W18,
2-lamp 54W T5H0, 100W HID
347| 80| 102| 105| 106
AL04 (10000LM)| MVOLT| 84| 9613| 114| 9891| 118| 10003| 119| 4 lamp 32W T8,
2-lamp 54W 15H0, 150W HID
347| 98| 98| 101| 102
*All values are typical and are at 25C. Actual performance may vary and is dependent on operating environment.
PROJECTED LUMEN MAINTENANCE
Lumen Maintenance Factor| 0.91| 0.81| 0.75
Operating Hours| 40,000| 90,000| 120,000
*Actual performance may vary based on ambient temperature of installed location.
Ambient Temperature Ratings
Fixture Length| Lumen Package| Temperature rating|
Temperature rating with IE7WC
---|---|---|---
L48| 3000LM| -40° C – 45° C| 0° C to 30° C
4000LM| -40° C – 45° C| 0° C to 30° C
5000LM| -40° C – 45° C| 0° C to 30° C
6000LM| -40° C – 35° C| 0° C to 30° C
L96| 6000LM| -40° C – 30° C| 0° C to 30° C
8000LM| -40° C – 30° C| 0° C to 30° C
10000LM| -40° C – 30° C| 0° C to 30° C
12000LM| -40° C – 30° C| 0° C to 30° C
Number of Boards and Drivers
Fixture length | Lumen package | Driver QTY | Board QTY |
---|---|---|---|
L48 | 3000LM | 1 | 1 |
4000LM | 1 | 1 | |
5000LM | 1 | 1 | |
6000LM | 1 | 1 | |
ALO3 | 1 | 1 | |
L96 | 6000LM | 1 | 2 |
8000LM | 1 | 2 | |
10000LM | 1 | 2 | |
12000LM | 1 | 2 | |
ALO4 | 1 | 2 |
INDUSTRIAL: One Lithonia Way, Conyers,
GA 30012 Phone: 800-705-SERV (7378)
techsupport-Industrial@acuitybrands.com
www.lithonia.com
© 2019-2022 Acuity Brands Lighting, Inc. All rights reserved.
Documents / Resources
|
Acuity Brands CSVT Vapor Tight LED Strip
Light
[pdf] Owner's Manual
CSVT Vapor Tight LED Strip Light, CSVT, Vapor Tight LED Strip Light, Tight LED
Strip Light, LED Strip Light, Strip Light, Light
---|---
References
- A+ Certified
- Contractor Select | Readily Available Light Fixtures | Acuity Brands
- Lithonia Lighting® | Best Value in Lighting
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>