BORMANN BPP2460 Negative Pressure Fit Check Instruction Manual
- July 20, 2024
- BORMANN
Table of Contents
- BORMANN BPP2460 Negative Pressure Fit Check
- Product Information
- Product Usage Instructions
- Safety Warning
- Use Limitations
- Inspection Procedure
- Cleaning and Storage Instructions
- Fitting Instructions
- Negative Pressure Fit Check
- Maintenance
- TECHNICAL SPECIFICATIONS
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BORMANN BPP2460 Negative Pressure Fit Check
Product Information
Product Specifications
- Model: BPP2460 073741
- Version: v2.2
- Languages: EN, IT, EL, BG, RO, HR
- Website: www.nikolaoutools.com
Product Usage Instructions
Instructions for use
Before using the product, carefully read the manual to prevent tool damage,
physical injury, or property damage. Ensure the manual is stored for future
reference.
Use Restrictions
Ensure hair is not passing under the face seal. Always check for a tight mask
seal before entering a hazardous atmosphere.
Inspection Procedure
Inspect the respirator before each use. Replace damaged parts immediately.
Check for cracks, tears, dirt, and ensure straps are intact and elastic.
Cleaning and Storage Instructions
- After use, clean the face piece with medical-grade alcohol (excluding cartridges/filters) and let dry.
- Store the cleaned respirator in its original packaging away from direct sunlight or heat sources.
- The shelf life of an unused mask is five years.
Fitting Instructions
Assemble cartridges/filters before wearing. Adjust head straps for a proper
fit. Perform a positive/negative pressure seal check each time the respirator
is worn.
Frequently Asked Questions (FAQ)
-
Q: How often should I clean the respirator?
A: Cleaning is recommended after each use. Remove cartridges/filters before cleaning. -
Q: What is the shelf life of an unused mask?
A: The shelf life of an unused mask is five years.
Safety Warning
Warning:
- Read the manual carefully before use. Failure to follow the warnings and instructions may result in tool damage, physical injury, and/or property damage. Store the manual in a safe place for future reference.
- Use this product before the expiration date. The respirators help protect against certain airborne contaminants. Misuse may result in sickness or death. For proper use, see instructions.
- Before using, read the instructions very carefully and make sure that the wearer fully understands all the instructions in this booklet.
- Failure to follow all instructions and limitations by using the respirator and/or failure to wear this respirator during exposure at all times can reduce respiraton protection effectiveness and may result in sickness or death.
- The dust, fumes, mist, gases, and vapors can be dangerous to your health including those which you cannot see.
- Leave the contaminated area immediately and replace the respirator if:
- The respirator becomes damaged.
- You taste or smell contaminants or an irritation occurs.
- Breathing becomes difficult.
- Dizziness or other distress occurs.
- The cartridges or filters must be replaced as soon as increased breathing resistance occurs.
- Stay away from the contaminated areas when replacing the cartridges or paint pre-filters.
Use Limitations
- The full mask does not supply oxygen. Do not use it in atmospheres containing less than 19.5% oxygen.
- Do not use this respirator in oxygen-enriched air.
- Do not use this respirator in explosive atmospheres.
- Do not use this respirator when concentrations of contaminants are:
- lmmediately dangerous to life and health.
- Unknown contaminants.
- Do not abuse or misuse this respirator.
- The beard/mustache at the sealing area of the mask can cause leaks. Therefore, it is unlikely that the requirements for leakage will be achieved if this facial hair passes under the face seal. Always make sure the mask forms a tight seal and the cartridges and/or filters are attached before entering a hazardous atmosphere.
Inspection Procedure
The respirator must be inspected before each use to ensure that it is in good operating condition. The face piece should be replaced upon observation of damaged or defective parts. The following inspection procedure is suggested:
- Check the full mask for any cracks, tears,s and/or dirt.
- Make sure that the head straps are intact and have good elasticity.
- Examine all plastic and rubber parts for signs of cracking or fatigue.
Cleaning and Storage Instructions
- Cleaning is recommended after use; Remove the cartridges or filters before cleaning.
- Clean the face piece (excluding cartridges and filters) with medical grade alcohol, and let dry in room temperature.
- The cleaned respirator should be stored away in its original packaging or in a container box from contaminated areas when not in use. Always remember to stay away from direct daylight or any source of heat.
- The shelf life of an unused mask is five years.
Fitting Instructions
NOTE: Assemble cartridges/filters before wearing.
- Before using cartridges or filters must assemble onto the respirator and tighten them up clockwise (see Fig.1)
- Fully loosen all five head straps. With one hand pull your hair back from the sealing area. Place the chin in the chin cup of the respirator. While holding the facepiece in place, pull the head strap to the back of the head (see Fig. 2).
- Pull the ends of the five straps to adjust tightness starting with the neck straps first. Then the forehead straps. Do not over-lighten the straps (see Fig.3)
- Each time the respirator is worn, a positive and/or negative pressure seal check must be performed.
Negative Pressure Fit Check
NOTE: Assemble cartridges/filters before wearing.
Seal both respiratory filters and/or cartridges with your palms and breathe in
until a negative pressure (suction) is generated (see Fig.4). Hold your breath
for a moment. If you feel the respirator is slightly collapsing, pull closer
to your face with no leaks between the face and the face piece. In this way, a
proper fit has been achieved. If not, readjust the face piece and/or readjust
the straps to eliminate the air leakage. Repeat the test until a successful
fit check is achieved.
PERFORM A NEGATIVE PRESSURE FACE FIT CHECK. IF YOU CAN NOT ACHIEVE A PROPER FIT, DO NOT ENTER THE CONTAMINATED AREA.
- a. Lens
- b. Band Clamp
- c. Breathing Room Assembly
- d. Inhalation Valve
- e. Inhalation Valve Seat
- f. Exhalation Valve
- g. Exhalation Valve Cover
- h. Head Strap Assembly, Silicone
- i. Removable DIN Connector
- j. Inhalation Port Gasket
- k. Cartridge
- l. Nose Cup Assembly, Silicone
Maintenance
Use only original spare parts. After use, the mask must be checked and cleaned. Replace damaged parts (see Fig.5).
-
Replacing the inhalation valve disc:
Remove the valve discs from the inside of the mask and replace them. Check whether the discs remain flat. -
Replacing the head harness:
Remove the head harness from the face piece and put a new harness into place.
Production date (see inside of the mask body)
- The number in the center of the circle represents the year.
- The number indicated by the arrow represents the month.
ATTENTION:
To guarantee the security of the users, the device should be examined
regularly, all year round, by an expert person, strictly according to the
manufacturer’s data, with repeated and prescribed examination procedures. Only
then, the efficiency and longevity of the device can be reached.
TECHNICAL SPECIFICATIONS
Technical data
Model| BPP2460
Other features| • Full face mask for 2 filters (not included)
• The main body uses high-liquid silicone which is anti-aging and anti- allergic
• The double silicone mask edge is very good for air tightness, parts of the mouth and nose can fit various face
• Large perimeter visibility
• PC window anti-fog inside and anti-friction outside
• The threaded interface is very convenient for replacing cartridges
• Ηead ties in 5 points
• Suitable for filters: BPP2464-2, BPP2466-2, BPP2468-2
- The manufacturer reserves the right to make minor changes to product design and technical specifications without prior notice unless these changes significantly affect the performance and safety of the products. The parts described/illustrated in the pages of the manual that you hold in your hands may also concern other models of the manufacturer’s product line with similar features and may not be included in the product you just acquired.
- To ensure the safety and reliability of the product and the warranty validity, all repair, inspection, or replacement work, including maintenance and special adjustments, must only be carried out by technicians of the authorized service department of the manufacturer.
- Always use the product with the supplied equipment. Operation of the product with non-provided equipment may cause malfunctions or even serious injury or death. The manufacturer and the importer shall not be liable for injuries and damages resulting from the use of non-conforming equipment.
The instructions manual is also available in digital format on our website www.nikolaoutools.com. Find it by entering the product code in the Search field.
Read User Manual Online (PDF format)