TECHNICAL SPECIFICATIONS

  • The manufacturer reserves the right to make minor changes to product design and technical specifications without prior notice unless these changes significantly affect the performance and safety of the products. The parts described/illustrated in the pages of the manual that you hold in your hands may also concern other models of the manufacturer’s product line with similar features and may not be included in the product you just acquired.
  • To ensure the safety and reliability of the product and the warranty validity, all repair, inspection or replacement work, including maintenance and special adjustments, must only be carried out by technicians of the authorized service department of the manufacturer.
  • Always use the product with the supplied equipment. Operation of the product with non- provided equipment may cause malfunctions or even serious injury or death. The manufacturer and the importer shall not be liable for injuries and damages resulting from the use of non-conforming equipment.

Technical data

Model| BTC2050
Working hours| 2-3 h
Carry weight (vertical)| 150 kg
Diameter| 205 mm
Battery| 3.7 V / 2400 mA
Other features| Digital display pressure, two-digit display
Includes| 1pc Battery, 1pc Charger
DISPLAY DESCRIPTION

on| Displays 0.5 seconds after power on.
of| Displays 0.5 seconds after shutdown.
Err| The air pressure does not reach the minimum pressure value within 8 seconds, and the automatic shutdown enters the standby state.
Lo| The battery is about to die and needs to be charged immediately.
NUMERICAL VALUE| Pressure value displayed in power-on state.
FUNCTION DESCRIPTION

**** BOOT / INHALE| Long press the power button (in sleep state).
Short press the power button (in standby state).
SHUTDOWN PRESSURE| Double-click the power button (enter the standby state, and enter the sleep state without operation for 10 minutes).
**** INHALE / INFLATE| Automatically inhale after starting the machine, and automatically stop after reaching the set minimum pressure value. There is no slight air leakage in operation for a period of time. After reaching the set minimum safe pressure value, it will automatically start the machine to replenish air, and automatically stop after reaching the highest pressure value.