Chicago Pneumatic CP873C-HD Tire Buffer User Manual
- June 3, 2024
- Chicago Pneumatic
Table of Contents
- Chicago Pneumatic CP873C-HD Tire Buffer
- SPECIFICATION
- Air Diagram
- Assembly of Tool with Pneumatic Hose
- Disassembly of Tool from Pneumatic Hose
- Technical Data
- Declarations
- Safety
- Use
- Maintenance instructions
- Useful Information
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Chicago Pneumatic CP873C-HD Tire Buffer
WARNING
Read all safety warnings and instructions. Failure to follow the safety
warnings and instructions may result in electric shock, fire and/or serious
injury.
Save all warnings and instructions for future reference.
SPECIFICATION
CP873C- HD | CP873C- HDES | ||
---|---|---|---|
Speed (RPM) | 3500 | 3500 | |
Power (W) | 500 | 500 | |
Power (hp) | 0.67 | 0.67 | |
Collet (inch) | 7/16 | 7/16 | |
Collet (mm) | 11 | 11 | |
Air Consumption (cfm) | 4.00 | 4.00 | |
Air Consumption (l/s) | 1.9 | 1.9 | |
Air Inlet (“) | 1/4 | 1/4 | |
Net weight (kg) | 1.05 | 1.16 | |
Net weight (lb) | 2.31 | 2.56 | |
Sound Pressure LPA(dB(A)) | 88.5 | 87.7 | |
Sound Pressure LWA(dB(A)) | 99.5 | 98.7 | |
Vibration and(m/s²) | 0.73 | 0.82 | |
Vibration K (m/s²) | 0.57 | 0.58 | |
Length (“) | 8.7 | 11.9 | |
Length (mm) | 222 | 301 | |
Diameter (“) | 1.8 | 1.8 | |
Diameter (mm) | 46 | 46 | |
Height (“) | 3.0 | 3.0 | |
Height (mm) | 75 | 75 |
Air Diagram
CP873C-HD
CP873C-HDES
Assembly of Tool with Pneumatic Hose
Disassembly of Tool from Pneumatic Hose
Technical Data
Tool Data
Free | Air Inlet | Weight | Weight | |
---|---|---|---|---|
speed | (“) | (kg) | (lb) |
__
CP873C-HD
| (rpm)
3500
| __
1/4 NPT
| __
1.05
| __
2.31
CP873C-HDES| 3500| 1/4 NPT| 1.16| 2.56
Maximum working pressure
6.3 bar / 90 psig
Declarations
EU DECLARATION OF CONFORMITY
We, CHICAGO PNEUMATIC Tool Co.LLC
1815 Clubhouse Road, Rock Hill, SC 29730 – USA, declare under our sole
responsibility that the product (with name, type, and serial number, see front
page) is in conformity with the following Directive(s):
Harmonized standards applied: EN ISO 11148-9: 2011
Authorities can request relevant technical information from Pascal Roussy, R&D
Manager, Ets Georges Renault, 38 rue Bobby Sands, BP10273 44818 Saint
Herblain, France
Saint-Herblain, 2022/03/01
Pascal ROUSSY
Signature of issuer
UK Declaration of Conformity
We CHICAGO PNEUMATIC Tool Co.LLC 1815 Clubhouse Road, Rock Hill, SC 29730
-USA, declare under our sole responsibility that the product (with name, type,
and serial number, see front page) is in conformity with the following UK
Regulation(s):
Supply of Machinery (Safety) Regulations 2008
Designated Standards applied:
EN ISO 11148-9: 2011
Saint-Herblain, 2022/03/01
Pascal ROUSSY
Signature of issuer
Authorities can request relevant technical information from:
UK Authorized Representative:
Air Compressors & Tools Ltd
Zodiac – Unit 4, Boundary way
Hemel Hempstead Industrial Estate, HP27SJ Hempstead
Hertfordshire – UK
Contact: M.Taylor
Noise and Vibration
These declared values were obtained by laboratory-type testing in accordance
with the stated standards and are suitable for comparison with the declared
values of other tools tested in accordance with the same standards. These
declared values are not adequate for use in risk assessments and values
measured in individual workplaces may be higher. The actual exposure values
and risk of harm experienced by an individual user are unique and depend upon
the way the user works, the workpiece, and the workstation design, as well
upon the exposure time and the physical condition of the user.
We, CHICAGO PNEUMATIC Tool Co.LLC, cannot be held liable for the consequences of using the declared values, instead of values reflecting the actual exposure, in an individual risk assessment in a workplace situation over which we have no control. This tool may cause hand-arm vibration syndrome if its use is not adequately managed. An EU guide to managing hand-arm vibration can be found by accessing http://www.pneurop.eu/index.php and selecting ‘Tools’ then ‘Legislation’.
We recommend a programme of health surveillance to detect early symptoms which may relate to noise or vibration exposure, so that management procedures can be modified to help prevent future impairment.
If this equipment is intended for fixtured applications: The noise emission is given as a guide to the machine builder. Noise and vibration emission data for the complete machine should be given in the instruction manual for the machine.
Regional Requirements
WARNING
This product can expose you to chemicals including lead, which is known to the
State of California to cause cancer and birth defects or other reproductive
harm. For more information go to https://www.p65warnings.ca.gov/.
Safety
DO NOT DISCARD – GIVE TO THE USER
WARNING
Read all safety warnings, instructions, illustrations, and specifications
provided with this product. Failure to follow all instructions listed below
may result in electric shock, fire, property damage, and/or serious injury.
Save all warnings and instructions for future reference.
WARNING
All locally legislated safety rules regarding installation, operation, and
maintenance shall be respected at all times.
Statement of Use
- For professional use only.
- This product and its accessories must not be modified in any way.
- Do not use this product if it has been damaged.
- If the product data or hazard warning signs on the product cease to be legible or become detached, replace them without delay.
- The product must only be installed, operated, and serviced by qualified personnel in an industrial environment.
Intended Use
Power tool equipped with slip chuck and 3/8 in.-24 adapter for use with
various rasps for tire repair – No other use is permitted.
Use
Installation/Operation
- Fix the accessories properly to the tool.
- Connect the device as shown in Fig. 01.
- To start the machine, pull the trigger (A). Machine speed is increased by increasing pressure on the trigger. Release the trigger to stop.
Maintenance instructions
- Follow local country environmental regulations for safe handling and disposal of all components.
- Maintenance and repair work must be carried out by qualified personnel using only original spare parts. Contact the manufacturer or your nearest authorised dealer for advice on technical service or if you require spare parts.
- Always ensure that the machine is disconnected from the energy source to avoid accidental operation.
- Disassemble and inspect the tool every three 3 months (500 hours) if the tool is used every day. Replace damaged or worn parts.
- The safety screw should be replaced when damaged, and in any case, replaced during maintenance operations (every 500 hours).
- To keep downtime to a minimum, the following service kit is recommended: a Tune-up kit
Disposal
- The disposal of this equipment must follow the legislation of the respective country.
- All damaged, badly worn, or improperly functioning devices MUST BE TAKEN OUT OF OPERATION.
Useful Information
Safety Data Sheet
The Safety Data Sheets describe the chemical products sold by Chicago
Pneumatic.
Please consult the Chicago Pneumatic website for more information
qr.cp.com/sds.
Country of Origin
Taiwan
Copyright
© Copyright 2022, CHICAGO PNEUMATIC Tool Co.LLC, 1815 Clubhouse Road, Rock
Hill, SC 29730 – USA
All rights reserved. Any unauthorized use or copying of the contents or part thereof is prohibited. This applies in particular to trademarks, model denominations, part numbers, and drawings. Use only authorized parts. Any damage or malfunction caused by the use of unauthorised parts is not covered by Warranty or Product Liability.
ABOUT CHICAGO PNEUMATIC
Since 1901 the Chicago Pneumatic (CP) name has represented reliability and
attention to customer needs, with construction, maintenance, and production
tools and compressors designed for specific industrial applications. Today, CP
has a global reach, with local distributors around the world.
Our people start every single day with a passion to research, develop, manufacture, and deliver new products that are meant to meet your needs not only today but tomorrow as well.
TO LEARN MORE, VISIT WWW.CP.COM.
To find more information about your tool, scan the QR code or go tom.cp.com.
References
- m.cp.com
- qr.cp.com/
- Chemwatch - Login
- qr.cp.com/sds)を参照してください。
- Chicago Pneumatic Homepage - Chicago Pneumatic
- p65warnings.ca.gov/
- Pneurop - Pneurop
- Pneurop - Pneurop
- p65warnings.ca.gov/
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>