Chicago Pneumatic CP871C, CP873C Tire Buffer Instruction Manual
- June 3, 2024
- Chicago Pneumatic
Table of Contents
- Chicago Pneumatic CP871C, CP873C Tire Buffer
- Table 1: Technical Specifications
- Tire Buffer
- Safety Information
- Noise and Vibration
- UK Declaration of Conformity
- Regional Requirements
- Intended Use
- Use
- Maintenance instructions
- Useful Information
- Original instructions
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Chicago Pneumatic CP871C, CP873C Tire Buffer
WARNING
To reduce risk of injury, everyone using, installing, repairing,
maintaining, changing accessories on, or working near this tool MUST read and
understand these instructions before performing any such task.
DO NOT DISCARD – GIVE TO USER
| CP871C| CP873C
---|---|---
Free Speed| 22000| 3000
Power (W)| 350| 350
Power (hp)| 0.47| 0.47
Chuck Size (“)| 3/8| 7/16
Chuck Size (mm)| 10| 11
Air Consumption (cfm)| 1.9| 1.9
Air Consumption (l/s)| 3.90| 3.90
Air Inlet (“)| 1/4 NPT| 1/4 NPT
Weight (kg)| 0.75| 1.02
Weight (lb)| 1.65| 2.25
Sound Pressure LPA(dB(A))| 88| 87
Sound Pressure LWA(dB(A))| 99| 98
Vibration and(m/s²)| 4.04| < 2.5
Vibration K (m/s²)| 0.89|
Length (“)| 7.9| 8.7
Length (mm)| 201| 220
Diameter (“)| 1.8| 1.8
Diameter (mm)| 46| 46
Height (“)| 3.0| 3.0
Height (mm)| 75| 75
| |
Table 1: Technical Specifications
Illustration 1: Air Diagram
Tire Buffer
Safety Information
Technical Data
Tool Data
Maximum working pressure
6.3 bar / 90 sprig
Declarations
EU DECLARATION OF CONFORMITY
We, CHICAGO PNEUMATIC Tool Co. LLC
1815 Clubhouse Road, Rock Hill, SC 29730 – USA, declare under our sole
responsibility that the product (with name, type and serial number, see front
page) is in conformity with the following Directive(s):
Harmonized standards applied: EN ISO 11148-3: 2013, EN ISO 11148-9: 2011
Authorities can request relevant technical information from:
Noise and Vibration
These declared values were obtained by laboratory type testing in accordance
with the stated standards and are suitable for comparison with the declared
values of other tools tested in accordance with the same standards. These
declared values are not adequate for use in risk assessments and values
measured in individual work places may be higher. The actual exposure values
and risk of harm experienced by an individual user are unique and depend upon
the way the user works, the workpiece and the workstation design, as well upon
the exposure time and the physical condition of the user.
We, CHICAGO PNEUMATIC Tool Co. LLC, cannot be held liable for the consequences
of using the declared values, instead of values reflecting the actual
exposure, in an individual risk assessment in a work place situation over
which we have no control.
This tool may cause hand-arm vibration syndrome if its use is not adequately
managed. An EU guide to managing hand-arm vibration can be found by accessing
http://www.pneurop.eu/index.php and selecting ‘Tools’ then ‘Legist- Pascal
Rousey, R&D Manager, Est Georges Renault, 38 rue Bobby Sands, BP10273 44818
Saint Harlan, France
Saint-Harlan, 2022/03/01 Pascal ROUSSY Signature of issuer We recommend a
programmed of health surveillance to detect early symptoms which may relate to
noise or vibration expo-sure, so that management procedures can be modified to
help prevent future impairment.
If this equipment is intended for fixtured applications: The noise emission is given as a guide to the machine-builder. Noise and vibration emission data for the complete machine should be given in the instruction manual for the machine.
UK Declaration of Conformity
We CHICAGO PNEUMATIC Tool Co. LLC 1815 Clubhouse Road, Rock Hill, SC 29730 -USA, declare under our sole responsibility that the product (with name, type and serial number, see front page) is in conformity with the following UK Regulation(s):
Supply of Machinery (Safety) Regulations 2008 Designated Standards applied:
EN ISO 11148-3: 2013, EN ISO 11148-9: 2011
Saint-Herblain,2022/03/01 Pascal ROUSSY Signature of issuer
Authorities can request relevant technical information from:
UK Authorized Representative:
- Air Compressors & Tools Ltd
- Zodiac – Unit 4, Boundary way
- Heel Hempstead Industrial Estate, HP27SJ Hempstead
- Hertfordshire – UK
- Contact: M. Taylor
Regional Requirements
WARNING
This product can expose you to chemicals including lead, which is known to the
State of California to cause cancer and birth defects or other reproductive
harm. For more information go to https://www.p65warnings.ca.gov/
Safety
DO NOT DISCARD – GIVE TO USER
WARNING Read all safety warnings, instructions, illustrations and
specifications provided with this product.
Failure to follow all instructions listed below may result in electric shock,
fire, property damage and/or serious injury.
Save all warnings and instructions for future reference.
WARNING All locally legislated safety rules regarding installation,
operation and maintenance shall be respected at all times.
Statement of Use
- For professional use only.
- This product and its accessories must not be modified in any way.
- Do not use this product if it has been damaged.
- If the product data or hazard warning signs on the product cease to be legible or become detached, replace with-out delay.
- The product must only be installed, operated and serviced by qualified personnel in an industrial environment.
Intended Use
Power tool equipped with slip chuck and 3/8 in.-24 adapter or drill chuck for use with various rasps for tire repair – No other use is permitted.
Use
Installation / Operation
- Fix the accessories properly to the tool.
- Connect device as shown in Fig. 01.
- To start the machine, pull the trigger (A). Machine speed is increase by increasing pressure on the trigger. Release the trigger to stop.
Maintenance instructions
- Follow local country environmental regulations for safe handling and disposal of all components.
- Maintenance and repair work must be carried out by qualified personnel using only original spare parts. Con-tact the manufacturer or your nearest authorized dealer for advice on technical service or if you require spare parts.
- Always ensure that the machine is disconnected from energy source to avoid accidental operation.
- Disassemble and inspect the tool every three 3 months (500 hours) if the tool is used every day. Replace dam-aged or worn parts.
- The safety screw should be replaced when damaged, and in any case replaced during maintenance operations (every 500 hours).
- To keep downtime to a minimum, the following service kit is recommended : Tune-up kit
Disposal
- The disposal of this equipment must follow the legislation of the respective country.
- All damaged, badly worn or improperly functioning de-vices MUST BE TAKEN OUT OF OPERATION.
Useful Information
Safety Data Sheet
The Safety Data Sheets describe the chemical products sold by Chicago
Pneumatic.
Please consult the Chicago Pneumatic website for more in-formation
qr.cp.com/suds.
Country of Origin
Taiwan
Copyright
© Copyright 2022, CHICAGO PNEUMATIC Tool Co. LLC, 1815 Clubhouse Road, Rock
Hill, SC 29730 – USA
All rights reserved. Any unauthorized use or copying of the contents or part
thereof is prohibited. This applies in particular to trademarks, model
denominations, part numbers and drawings. Use only authorized parts. Any
damage or mal-function caused by the use of unauthorized parts is not covered
by Warranty or Product Liability.
Original instructions
ABOUT CHICAGO PNEUMATIC
Since 1901 the Chicago Pneumatic (CP) name has represented reliability and
attention to customer needs, with construction, maintenance and production
tools and compressors designed for specific industrial applications. Today, CP
has a global reach, with local distributors around the world.
Our people start every single day with a passion to research, develop,
manufacture and deliver new products that are meant to meet your needs not
only today, but tomorrow as well.
TO LEARN MORE, VISIT WWW.CP.COM
To find more information about your tool, scan the QR code or go to m.cp.com
References
- m.cp.com
- qr.cp.com/
- Chemwatch - Login
- qr.cp.com/sds)を参照してください。
- Chicago Pneumatic Homepage - Chicago Pneumatic
- p65warnings.ca.gov/
- Pneurop - Pneurop
- Pneurop - Pneurop
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>