Chicago Pneumatic CP86 Series Battery Torque Wrench Instruction Manual
- June 4, 2024
- Chicago Pneumatic
Table of Contents
PRODUCT INFORMATION
CP86 Series
CHICAGO PNEUMATIC
BATTERY TORQUE
WRENCH
CP86 Series Battery Torque Wrench
| +/- 4%*
---|---
| Connected
| Data collection”
| Sequence programming
| Tool lock. Error-proof
| Application library*
- C or CQ version only
- Based on hard joint 15° at nominal torque
Product description
1 Second trigger
2 Principle trigger
3 Display screen
4 Settings buttons| 5 Reporting LEDs
6 Reverse button
7 Reaction bar s-type (delivered with the tool)
---|---
Connected version
To unblock functionalities of CP86 connected versions C and CQ, download CPLinQ to your device and connect your tool to CPLinQ app.
|
---|---
https://apps.apple.com/app/app-store/id1547288636|
market://details?id=com.cp.cplinq
Installation & Operating Instructions
• Battery CP36XP25 (8940176068)
Battery wake up : Remove white protective sticker and plug the battery to CP charger CP18-36CH (8940176069).
•Reaction bar & Socket
Starting the tool
Fit the tool with a suitable socket.
Set the appropriate program on the tool.
Hold the tool by means of the handle, place the reaction bar on a suireaction
point and apply to the fastener to be tightened.
WARNING Risk of Injury
As the reaction force increases in proportion to the tightening torquthere is
a risk of severe bodily injury of the operator as a result of unexpected
behavior of the tool.
► Make sure that the tool is in perfect working order.
WARNING Risk of Burns
The motor may heat up during heavy-duty cycles.
► Wear gloves.
WARNING Crushing Hazard
Do a check of the rotational direction of the tool before start! A start in
an unexpected rotational direction can cause bodily injury or property damage
► Make sure that the rotational direction of the tool is correct before
starting the tool.
► Keep your hands away from the reaction bar while the tool is used.
► Press triggers to start the tool
Operating the tool
Torque set up
Stand-alone tools menu
Maintenance menu
Tools information menu
Units selection menu
| Triggers have been used in bad order| Press the second trigger first (1)
and maintain, then press main trigger (2) and maintain both until end of
tightening (refer to product description)
---|---|---
| One of the triggers has been released during tightening. Torque or angle
achieved is shown| Maintain both triggers until end of tightening
| Torque higher than maximum authorized OR angle not achievable because of
tool capacity exceeded|
| The tool has detected a rehit. You are probably trying to tighten an
already tightened bolt|
| The nut runner needs a maintenance due to time of operation| Contact service
center
| The nut runner needs a maintenance due to too many drops
| The nut runner needs a maintenance due to number of tightening
| The nut runner needs a maintenance due to number of untightening
| Level of battery is under 25%| Replace battery by fully loaded battery as
soon as possible (refer to battery wake-up procedure if needed)
| Level of battery is under 5%| Replace battery by fully loaded battery, tool
will turn off (refer to battery wake up procedure if needed)
| Tool system issue| Contact service center
| The tool is unable to communicate with the battery.| 1. Check if you are
using the right Battery (8940176068)
2. If the problem occurs again, contact your CP representative for support.
| The tool is out
functional
temperature range.| 1. Wait the tool cool down
2. Reduce duty cycle
3. If the problem occurs again, contact your CP representative for support.
Tool doesn’t start| | 1. Check that your Battery is awake
2. Check Battery charge level
3. If the problem occurs again, contact your CP representative for support.
Your tool cannot connect to CPLINQ| | 1. Check that your Bluetooth is active
on your terminal
2. If the problem occurs again, contact your CP representative for support.
Service & maintenance
Overhaul and preventive maintenance are recommended at regular intervals.
Maintenance should be performed by qualified personnel only.
Website Information concerning our Products, Accessories, Spare Parts,
exploded views and Published Matters can be found on the CP website. Please
visit: www.cp.com.
The use of spare parts other than those originally supplied by the
manufacturer may result in a drop in performance or in increased maintenance
and level of vibration and in the full cancellation of the manufacturer’s
liability.
For tool calibration or all other servicing operation, refer to your local
service center.
© Chicago Pneumatic – 6159990070
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>