Specification

Product Glance Value
Model S21 Hyd.
Version m0-10
Crypto algorithm/coins **SHA256
Typical Hashrate, TH/s (1-1) 335
Power on wall @35℃(1-2), Watt (1-1) 5360
Power efficiency on wall@35℃(1-2), J/TH (1-1) 16.0
Detailed Characteristics Value
--- ---

Power supply
Phase| 3
Input voltage, Volt (2-1)| 380~415
Input frequency range, Hz| 50~60
Input max current, Amp| 12
Hardware configuration
Network connection mode| RJ45 Ethernet 10/100M
Server size (LengthWidthHeight, w/o package), mm| 339163207
Server size (LengthWidthHeight, with package), mm| 570316430
Net weight, kg| 12.3
Gross weight, k g| 13.6
Environment requirements
Inlet coolant temperature, °C| 20~50
Coolant flow, L/min| 8.0~10.0
Coolant pressure, bar| ≤3.5
Working coolant(2-2)| Antifreeze/ Pure water/Deionized water


Coolant pH value

| Antifreeze: 7.0~9.0 Prue water: 6.5~7.5

Deionized water 8.5~9.5

Diameter of coolant pipe connector, mm| OD10
Storage temperature, °C| -20~70
Operation humidity(non-condensing), RH| 10~90%

Notes

  1. The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power on wall and power efficiency on wall fluctuate by ±5%.
    • Inlet coolant temperature.
  2. Caution : Wrong input voltage may cause server damaged.
    • For detailed working coolant use and maintenance instructions, please refer to “ANTSPACE HK3 Water Cooling Container & Dry-Wet Tower Product Manual”, Chapter 9, Article 3, Point 6, “Maintenance of Coolant”!

Product Usage Instructions

Setup and Connection

  1. Ensure the power supply phase is compatible with the server requirements (3-phase power).
  2. Connect the server to the network using the RJ45 Ethernet port.

Coolant Management

  1. Use the recommended coolant type based on the provided guidelines.
  2. Maintain the coolant flow within the specified range of 8.0~10.0 L/min.

Operating Conditions

  1. Operate the server within the temperature range of -20~70°C and humidity of 10~90%.

Performance Curve

  1. Hashrate vs. Inlet Coolant Temperature

BITMAIN ANTMINER S21 Hyd 335T BTC Miner-fig-
\(2\)

  1. Power Efficiency vs. Inlet Coolant Temperature

BITMAIN ANTMINER S21 Hyd 335T BTC Miner-fig-
\(1\)

  1. The hashrate value, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power efficiency on wall fluctuate by ±5%.

FAQ’s

Q: What is the recommended coolant for the S21 Hyd.?
A: The recommended coolants are Antifreeze, Pure water, or Deionized water based on their respective pH values.

Q: What is the ideal operating temperature range for the server?
A: The server should be operated within a temperature range of -20~70°