BITMAIN s9 Bitcoin Antminer Installation Guide
- May 15, 2024
- BITMAIN
Table of Contents
s9 Bitcoin Ant miner
Installation Guide
S17e Server
Installation Guide
Document Version 1.0
Oct. 2019
s9 Bitcoin Ant miner
© Copyright Bitmain Technologies Holding Company 2007 – 2022, All rights
reserved.
Bitmain Cayman (hereinafter referred to as ‘Bitmain’) reserves the right to
make corrections, modifications, enhancements, improvements, and other changes
to its products and services at any time and to discontinue any product or
service without notice.
Customers should obtain the latest relevant information before placing orders
and should verify that such information is current and complete. All products
are sold subject to Bitmain’s terms and conditions of sale supplied at the
time of order acknowledgment.
Bitmain warrants performance of its products to the specifications applicable
at the time of sale in accordance with Bitmain’s standard warranty. Testing
and other quality control techniques are used to the extent Bitmain deems
necessary to support this warranty. Except where mandated by government
requirements, testing of all parameters of each product is not necessarily
performed.
Bitmain assumes no liability for third-party applications assistance.
Customers are responsible for their products and applications using Bitmain
components. To minimize the risks associated with customer products and
applications, customers should provide adequate design and operating
safeguards.
Bitmain does not warrant or represent that any license, either express or
implied, is granted under any Bitmain patent right, copyright or other Bitmain
intellectual property right relating to any combination, machine, or process
in which Bitmain products or services are used. Information published by
Bitmain regarding third-party products or services does not constitute a
license from Bitmain to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a
third party under the patents or other intellectual property of the third
party, or a license from Bitmain under the patents or other intellectual
property of Bitmain.
Resale of Bitmain products or services with statements different from or
beyond the parameters stated by Bitmain for that product or service voids all
express and any implied warranties for the associated Bitmain product or
service and is an unfair and deceptive business practice. Bitmain is not
responsible or liable for any such statements.
All company and brand products and service names are trademarks or registered
trademarks of their respective holders.
All text and figures included in this publication are the exclusive property
of Bitmain, and may not be copied, reproduced, or used in any way without the
express written permission of Bitmain. Information in this document is subject
to change without notice and does not represent a commitment on the part of
Bitmain. Although the information in this document has been carefully
reviewed, Bitmain does not warrant it to be free of errors or omissions.
Bitmain reserves the right to make corrections, updates, revisions or changes
to the information in this document.
Bitmain
Tel:+86-400-890-8855
www.bitmain.com
Overview
The S17e server is Bitmain’s newest version in the 17e server series. Power supply APW9+ is part of S17e server. All S17e servers are tested and configured prior to shipping to ensure easy set up.
Caution:
- The equipment must be connected to an earthed mains socket-outlet. The socket-outlet shall be installed near the equipment and shall be easily accessible.
- The equipment has two power inputs, only by connecting those two power supply sockets simultaneously can the equipment run. When the equipment is powered off, be sure to power off all power inputs.
- Please refer to the layout above to place your goods in usage in case of any damage.
- DO NOT remove any screws and cables tied on the product.
- DO NOT PRESS the metal button on the cover.
1.1 S17e Server Components
The main components and controller front panel of S17e servers are shown in
the following figure:
APW9+ Power Supply: Note:
- Power supply APW9+ is part of S17e server. For detailed parameters, please refer to the specifications below.
- Additional two power cords are needed.
1.2 Specifications
Model No.: 266-A
Version: S17e
Product Glance | Value |
---|---|
Crypto Algorithm/Coins | SHA256/BTC/BCH |
Hashrate, TH/s | 56.00 |
Reference power on wall, Watt | 2520 |
Reference power efficiency on wall @ 25°C , J/TH | 45.00 |
Detailed Characteristics | Value |
---|---|
Min | Typ |
Hashrate & Power
Hashrate, TH/s| | 56.00| 59.95
Power efficiency on wall @ 25°C , J/TH| 45.00| | 49.50
Power efficiency on wall @ 40°C , J/TH| 47.71| | 52.49
Power on wall, Watt (1-1)| 2520| | 3147
Power supply AC input voltage, Volt (1-2)| 200| 220| 240
Power supply AC input current, Amp(1-3)| | 11.45| 15.74
Power supply Input AC Frequency Range, Hz| 47| 50| 63
Hardware Configuration
Quantity of hash chips| 405
Quantity of hash boards| 3
Networking connection mode| RJ45 Ethernet 10/100M
Server Size (LengthWidthHeight, w/o package), mm(2-1)|
340178304.3
Net weight, kg (2-2)| 11.30
Noise, dBA @25 °C (2-3)| | | 82
Environment Requirements
Recommended operation temperature, °C| 5| 25| 35
Max operation temperature, °C| 0| 25| 40
Storage temperature,°C| -20| 25| 70
Operation humidity, RH| 10%| **| 90%**
Notes:
(1-1) Min condition: 25°C, min J/TH, typical Hashrate Max condition: 40°C, max
J/TH, max Hashrate
(1-2) Caution: Wrong input voltage may probably cause server damaged
(1-3) Typ condition: min reference power, typical AC input voltage Max
condition: max reference power, min AC input voltage
(2-1) Including PSU size
(2-2) Including PSU weight
(2-3) Max condition: Fan is under max RPM(rotation per minute)
Model No.: 266-A
Version: S17e
Product Glance | Value |
---|---|
Crypto Algorithm/Coins | SHA256/BTC/BCH |
Hashrate, TH/s | 60.00 |
Reference power on wall, Watt | 2700 |
Reference power efficiency on wall @ 25°C , J/TH | 45.00 |
Detailed Characteristics | Value |
---|---|
Min | Typ |
Hashrate & Power
Hashrate, TH/s| | 60.00| 63.95
Power efficiency on wall @ 25°C , J/TH| 45.00| | 49.50
Power efficiency on wall @ 40°C , J/TH| 48.39| | 53.23
Power on wall, Watt (1-1)| 2700| | 3404
Power supply AC input voltage, Volt (1-2)| 200| 220|
240
Power supply AC input current, Amp (1-3)| | 12.27| 17.02
Power supply Input AC Frequency Range, Hz| 47| 50| 63
Hardware Configuration
Quantity of hash chips| 405
Quantity of hash boards| 3
Networking connection mode| RJ45 Ethernet 10/100M
Server Size (LengthWidthHeight, w/o package), mm (2-1)|
340178304.3
Net weight, kg (2-2)| 11.30
Noise, dBA @25 °C (2-3)| | | 82
Environment Requirements
Recommended operation temperature, °C| 5| 25| 35
Max operation temperature, °C| 0| 25| 40
Storage temperature, °C| -20| 25| 70
Operation humidity, RH| 10%| | 90%
Notes:
(1-1) Min condition: 25°C, min J/TH, typical hashrate
Max condition: 40°C, max J/TH, max hashrate
(1-2) Caution: Wrong input voltage may probably cause server damaged
(1-3) Typ condition: min reference power, typical AC input voltage Max
condition: max reference power, min AC input voltage
(2-1) Including PSU size
(2-2) Including PSU weight
(2-3) Max condition: Fan is under max RPM(rotation per minute)
Model No.: 266-A
Version: S17e
Product Glance | Value |
---|---|
Crypto Algorithm/Coins | SHA256/BTC/BCH |
Hashrate, TH/s | 64.00 |
Reference power on wall, Watt | 2880 |
Reference power efficiency on wall @ 25°C , J/TH | 45.00 |
Detailed Characteristics | Value |
--- | --- |
Min | Typ |
Hashrate & Power
Hashrate, TH/s| | 64.00| 67.95
Power efficiency on wall @ 25°C , J/TH| 45.00| | 49.50
Power efficiency on wall @ 40°C , J/TH| 50.02| | 55.02
Power on wall, Watt (1-1)| 2880| | 3739
Power supply AC input voltage, Volt (1-2)| 200| 220|
240
Power supply AC input current, Amp (1-3)| | 13.09| 18.70
Power supply Input AC Frequency Range, Hz| 47| 50| 63
Hardware Configuration
Quantity of hash chips| 405
Quantity of hash boards| 3
Networking connection mode| RJ45 Ethernet 10/100M
Server Size (LengthWidthHeight, w/o package), mm (2-1)|
340178304.3
Net weight, kg (2-2)| 11.30
Noise, dBA @25 °C (2-3)| | | 82
Environment Requirements
Recommended operation temperature, °C| 5| 25| 35
Max operation temperature, °C| 0| 25| 40
Storage temperature, °C| -20| 25| 70
Operation humidity, RH| 10%| | 90%
Notes:
(1-1) Min condition: 25°C, min J/TH, typical hashrate Max condition: 40°C, max
J/TH, max hashrate
(1-2) Caution: Wrong input voltage may probably cause server damaged
(1-3) Typ condition: min reference power, typical AC input voltage Max
condition: max reference power, min AC input voltage
(2-1) Including PSU size
(2-2) Including PSU weight
(2-3) Max condition: Fan is under max RPM(rotation per minute)
Setting Up the Server
To set up the server:
The file IPReporter.zip is supported by Microsoft Windows only.
-
Go to the following site: https://shop.bitmain.com/support/download
-
Choose ‘Others’ and download the following file: IPReporter.zip.
-
Extract the file.
The default DHCP network protocol distributes IP addresses automatically. -
Right-click IPReporter.exe and run it as Administrator.
-
Select one of the following options:
■ Shelf, Step, Position – suitable for farm servers to mark the location of the servers.
■ Default – suitable for home servers. -
Click Start.
-
On the controller board, click the IP Report button. Hold it down until it beeps (about 5 seconds).The IP address will be displayed in a window on your computer screen.
-
In your web browser, enter the IP address provided.
-
Proceed to login using root for both the username and password.
-
In the Network section, you can assign a DHCP IP address (optional).
-
Click Save & Apply.
Configuring the Server
Setting Up the Pool
To configure the server:
- click General Settings.
- Set the options according to the following table:
Option| Description
---|---
Pool URL| Enter the URL of your desired pool.
The S17e servers can be set up with three mining pools, with decreasing priority from the first pool (pool 1) to the third pool (pool 3).
The pools with low priority will only be used if all higher priority pools are offline.
Worker| Your worker ID on the selected pool.
Password| The password for your selected worker. - Click Save & Apply to save and restart the server.
Monitoring Your server
To check the operating status of your server:
- Click the status marked below. (Here takes the server status of S17e-64T as an example) Note: The S17e server is with automatic frequency. Firmware will stop running when the Temp (PCB) reaches to 80 ℃ or Temp(chips) reaches to 95 ℃ ,there will be an error message “Fatal Error: Temperature is too high!” shown in the bottom of kernel log page.
- Monitor your server according to the descriptions in the following table:
Option| Description
---|---
ASIC#| Number of chips detected in the chain.
Frequency| ASIC frequency setting.
GH/S(RT)| Hash rate of each hash board (GH/s).
Temp(PCB)| Temperature of each hash board (°C). (Applied only to server with fixed frequency).
Temp(Chip)| Temperature of the chips on each hash board (°C).
ASIC status| One of the following statuses will appear:
● O – indicates OK
● X – indicates error
● – – indicates dead
Administering Your Server
5.1 Checking Your Firmware Version
To check your firmware version:
- In System, click the Overview tab.
- File System Version displays the date of the firmware your server uses. In the examples below, the servers are respectively using firmware version 20190910.
5.2 Upgrading Your System
Make sure that the S17e server remains powered during the upgrade process. If
power fails before the upgrade is completed, you will need to return it to
Bitmain for repair.
To upgrade the server’s firmware:
-
In System, click Upgrade.
-
For Keep Settings:
■ Select the check box to keep your current settings (default).
■ Clear the check box to reset the server to default settings. -
Click the (Browse) button and navigate to the upgrade file. Select the upgrade file, then click Flash image. A message appears notifying you if the S17e firmware can be upgraded and if yes, will then proceed to flash the image.
-
When the upgrade is completed, the following message appears:
-
Click one of the following options:
■ Reboot – to restart the server with the new firmware.
■ Go Back – to continue mining with the current firmware. The server will load the new firmware next time when it is restarted.
5.3 Modifying Your Password
To change your login password:
- In System, click the Administration tab.
- Set your new password, then click Save & Apply.
5.4 Restoring Initial Settings
To restore your initial settings
- Turn on the server and let it run for 5 minutes.
- On the controller front panel, press and hold the Reset button for 10 seconds.
Resetting your server will reboot it and restore its default settings. The red LED will automatically flash once every 15 seconds if the reset is operated successfully.
Environmental Requirements
Please run your server in accordance with the following requirements
- Basic Environmental Requirements:
1.1. Climatic Conditions: Description| Requirement
---|---
Operating Temperature| 0-40℃
Operating Humidity| 10-90%RH (non-condensing)
Storage Temperature| -20-70℃
Storage Humidity| 5-95%RH(non-condensing)
Altitude| <2000m
1.2. Site Requirements of the Server Running Room:
Please keep the server running room away from industrial pollution sources:
For heavy pollution sources such as smelters and coal mines, the distance
should be more than 5km.
For moderate pollution sources such as chemical industries, rubber and
electroplating industries, the distance should be more than 3.7km.
For light pollution sources such as food factories and leather processing
factories, the distance should be more than 2km.
If unavoidable, the site should be chosen in the perennial upwind direction of
the pollution source.
Please do not set your location within 3.7km from the seaside or the salt
lake. If unavoidable, it should be built as airtight as possible, equipped
with air conditioning for cooling.
1.3. Electromagnetic Environmental Conditions:
Please keep your site away from transformers, high-voltage cables,
transmission lines and high-current equipment, for example, there should be no
high-power AC transformers (>10KA) within 20 meters, and no high-voltage power
lines within 50 meters.
Please keep your site away from high-power radio transmitters, for example,
there should be no high-power radio transmitters (>1500W) within 100 meters.
- Other Environmental Requirements:
The server running room shall be free of explosive, conductive, magnetically conductive and corrosive dust. The requirements of mechanical active substances are shown below:
2.1 Requirements of Mechanical Active Substances**** Mechanical Active Substance| Requirement
---|---
Sand| <= 30mg/m3
Dust (suspended)| <= 0.2mg/m3
Dust (deposited)| <=1.5mg/m2h
2.2 Requirements of Corrosive Gas****
Corrosive Gas | Unit | Concentration |
---|---|---|
H2S | ppb | < 3 |
SO2 | ppb | < 10 |
Cl2 | ppb | < 1 |
NO2 | ppb | < 50 |
HF | ppb | < 1 |
NH3 | ppb | < 500 |
O3 | ppb | < 2 |
Note: ppb (part per billion) refers to the unit of concentration,1ppb stands for the volume ratio of part per billion.
Regulations:
FCC Notice (FOR FCC CERTIFIED MODELS):
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Note:
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
EU WEEE: Disposal of Waste Equipment by Users in Private Household in the
European Union
This symbol on the product or on its packaging indicates that this product
must not be disposed of with your other household waste. Instead, it is your
responsibility to dispose of your waste equipment by handling it over to a
designated collection point for the recycling of waste electrical and
electronic equipment. The separate collection and recycling of your waste
equipment at the time of disposal will help to conserve natural resources and
ensure that it is recycled in a manner that protects human health and the
environment. For more information about where you can drop off your waste
equipment for recycling, please contact your local city office, your household
waste disposal service or the shop where your purchased the product.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>