BITMAIN s9 Bitcoin Antminer Installation Guide

May 15, 2024
BITMAIN

s9 Bitcoin Ant miner
Installation Guide

BITMAIN s9 Bitcoin Antminer S17e Server Installation Guide
Document Version 1.0
Oct. 2019

s9 Bitcoin Ant miner

© Copyright Bitmain Technologies Holding Company 2007 – 2022, All rights reserved.
Bitmain Cayman (hereinafter referred to as ‘Bitmain’) reserves the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice.
Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to Bitmain’s terms and conditions of sale supplied at the time of  order acknowledgment.
Bitmain warrants performance of its products to the specifications applicable at the time of sale in accordance with Bitmain’s standard warranty. Testing and other quality control techniques are used to the extent Bitmain deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed.
Bitmain assumes no liability for third-party applications assistance. Customers are responsible for their products and applications using Bitmain components. To minimize the risks associated with customer products and applications,  customers should provide adequate design and operating safeguards.
Bitmain does not warrant or represent that any license, either express or implied, is granted under any Bitmain patent right, copyright or other Bitmain intellectual property right relating to any combination, machine, or process in which  Bitmain products or services are used. Information published by Bitmain regarding third-party products or services does not constitute a license from Bitmain to use such products or services or a warranty or endorsement thereof. Use of  such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from Bitmain under the patents or other intellectual property of Bitmain.
Resale of Bitmain products or services with statements different from or beyond the parameters stated by Bitmain for that product or service voids all express and any implied warranties for the associated Bitmain product or service and  is an unfair and deceptive business practice. Bitmain is not responsible or liable for any such statements.
All company and brand products and service names are trademarks or registered trademarks of their respective holders.
All text and figures included in this publication are the exclusive property of Bitmain, and may not be copied, reproduced, or used in any way without the express written permission of Bitmain. Information in this document is subject to  change without notice and does not represent a commitment on the part of Bitmain. Although the information in this document has been carefully reviewed, Bitmain does not warrant it to be free of errors or omissions. Bitmain reserves  the right to make corrections, updates, revisions or changes to the information in this document.
Bitmain
Tel:+86-400-890-8855
www.bitmain.com

Overview

The S17e server is Bitmain’s newest version in the 17e server series. Power supply APW9+ is part of S17e server. All S17e servers are tested and configured prior to shipping to ensure easy set up.BITMAIN s9 Bitcoin
Antminer - configured prior

Caution:

  1. The equipment must be connected to an earthed mains socket-outlet. The socket-outlet shall be installed near the equipment and shall be easily accessible.
  2. The equipment has two power inputs, only by connecting those two power supply sockets simultaneously can the equipment run. When the equipment is powered off, be sure to power off all power inputs.
  3. Please refer to the layout above to place your goods in usage in case of any damage.
  4. DO NOT remove any screws and cables tied on the product.
  5. DO NOT PRESS the metal button on the cover.

1.1 S17e Server Components
The main components and controller front panel of S17e servers are shown in the following figure:BITMAIN s9 Bitcoin Antminer - Server
Components

APW9+ Power Supply:BITMAIN s9 Bitcoin Antminer - Power
Supply Note:

  1. Power supply APW9+ is part of S17e server. For detailed parameters, please refer to the specifications below.
  2. Additional two power cords are needed.

1.2 Specifications
Model No.: 266-A
Version: S17e

Product Glance Value
Crypto Algorithm/Coins SHA256/BTC/BCH
Hashrate, TH/s 56.00
Reference power on wall, Watt 2520
Reference power efficiency on wall @ 25°C , J/TH 45.00

Detailed Characteristics Value
Min Typ

Hashrate & Power
Hashrate, TH/s| | 56.00| 59.95
Power efficiency on wall @ 25°C , J/TH| 45.00| | 49.50
Power efficiency on wall @ 40°C , J/TH| 47.71| | 52.49
Power on wall, Watt (1-1)| 2520| | 3147
Power supply AC input voltage, Volt (1-2)| 200| 220| 240
Power supply AC input current, Amp(1-3)| | 11.45| 15.74
Power supply Input AC Frequency Range, Hz| 47| 50| 63
Hardware Configuration
Quantity of hash chips| 405
Quantity of hash boards| 3
Networking connection mode| RJ45 Ethernet 10/100M
Server Size (LengthWidthHeight, w/o package), mm(2-1)| 340178304.3
Net weight, kg (2-2)| 11.30
Noise, dBA @25 °C (2-3)| | | 82
Environment Requirements
Recommended operation temperature, °C| 5| 25| 35
Max operation temperature, °C| 0| 25| 40
Storage temperature,°C| -20| 25| 70
Operation humidity, RH| 10%| **| 90%**

Notes:
(1-1) Min condition: 25°C, min J/TH, typical Hashrate Max condition: 40°C, max J/TH, max Hashrate
(1-2) Caution: Wrong input voltage may probably cause server damaged
(1-3) Typ condition: min reference power, typical AC input voltage Max condition: max reference power, min AC input voltage
(2-1) Including PSU size
(2-2) Including PSU weight
(2-3) Max condition: Fan is under max RPM(rotation per minute)

Model No.: 266-A
Version: S17e

Product Glance Value
Crypto Algorithm/Coins SHA256/BTC/BCH
Hashrate, TH/s 60.00
Reference power on wall, Watt 2700
Reference power efficiency on wall @ 25°C , J/TH 45.00

Detailed Characteristics Value
Min Typ

Hashrate & Power
Hashrate, TH/s| | 60.00| 63.95
Power efficiency on wall @ 25°C , J/TH| 45.00| | 49.50
Power efficiency on wall @ 40°C , J/TH| 48.39| | 53.23
Power on wall, Watt (1-1)| 2700| | 3404
Power supply AC input voltage, Volt (1-2)| 200| 220| 240
Power supply AC input current, Amp (1-3)| | 12.27| 17.02
Power supply Input AC Frequency Range, Hz| 47| 50| 63
Hardware Configuration
Quantity of hash chips| 405
Quantity of hash boards| 3
Networking connection mode| RJ45 Ethernet 10/100M
Server Size (LengthWidthHeight, w/o package), mm (2-1)| 340178304.3
Net weight, kg (2-2)| 11.30
Noise, dBA @25 °C (2-3)| | | 82
Environment Requirements
Recommended operation temperature, °C| 5| 25| 35
Max operation temperature, °C| 0| 25| 40
Storage temperature, °C| -20| 25| 70
Operation humidity, RH| 10%| | 90%

Notes:
(1-1) Min condition: 25°C, min J/TH, typical hashrate
Max condition: 40°C, max J/TH, max hashrate
(1-2) Caution: Wrong input voltage may probably cause server damaged
(1-3) Typ condition: min reference power, typical AC input voltage Max condition: max reference power, min AC input voltage
(2-1) Including PSU size
(2-2) Including PSU weight
(2-3) Max condition: Fan is under max RPM(rotation per minute)
Model No.: 266-A
Version: S17e

Product Glance Value
Crypto Algorithm/Coins SHA256/BTC/BCH
Hashrate, TH/s 64.00
Reference power on wall, Watt 2880
Reference power efficiency on wall @ 25°C , J/TH 45.00
Detailed Characteristics Value
--- ---
Min Typ

Hashrate & Power
Hashrate, TH/s| | 64.00| 67.95
Power efficiency on wall @ 25°C , J/TH| 45.00| | 49.50
Power efficiency on wall @ 40°C , J/TH| 50.02| | 55.02
Power on wall, Watt (1-1)| 2880| | 3739
Power supply AC input voltage, Volt (1-2)| 200| 220| 240
Power supply AC input current, Amp (1-3)| | 13.09| 18.70
Power supply Input AC Frequency Range, Hz| 47| 50| 63
Hardware Configuration
Quantity of hash chips| 405
Quantity of hash boards| 3
Networking connection mode| RJ45 Ethernet 10/100M
Server Size (LengthWidthHeight, w/o package), mm (2-1)| 340178304.3
Net weight, kg (2-2)| 11.30
Noise, dBA @25 °C (2-3)| | | 82
Environment Requirements
Recommended operation temperature, °C| 5| 25| 35
Max operation temperature, °C| 0| 25| 40
Storage temperature, °C| -20| 25| 70
Operation humidity, RH| 10%| | 90%

Notes:
(1-1) Min condition: 25°C, min J/TH, typical hashrate Max condition: 40°C, max J/TH, max hashrate
(1-2) Caution: Wrong input voltage may probably cause server damaged
(1-3) Typ condition: min reference power, typical AC input voltage Max condition: max reference power, min AC input voltage
(2-1) Including PSU size
(2-2) Including PSU weight
(2-3) Max condition: Fan is under max RPM(rotation per minute)

Setting Up the Server

To set up the server:
The file IPReporter.zip is supported by Microsoft Windows only.

  1. Go to the following site: https://shop.bitmain.com/support/download

  2. Choose ‘Others’ and download the following file: IPReporter.zip.

  3.  Extract the file.
    The default DHCP network protocol distributes IP addresses automatically.

  4. Right-click IPReporter.exe and run it as Administrator.

  5. Select one of the following options:
    ■ Shelf, Step, Position – suitable for farm servers to mark the location of the servers.
    ■ Default – suitable for home servers.

  6. Click Start.BITMAIN s9 Bitcoin Antminer - Power Supply1

  7. On the controller board, click the IP Report button. Hold it down until it beeps (about 5 seconds).BITMAIN s9 Bitcoin Antminer - controllerThe IP address will be displayed in a window on your computer screen.BITMAIN s9 Bitcoin Antminer - controller1

  8. In your web browser, enter the IP address provided.

  9. Proceed to login using root for both the username and password.

  10. In the Network section, you can assign a DHCP IP address (optional).

  11. Click Save & Apply.

BITMAIN s9 Bitcoin Antminer - DHCP

Configuring the Server

Setting Up the Pool
To configure the server:

  1. click General Settings.BITMAIN s9 Bitcoin Antminer - Server
  2. Set the options according to the following table:
    Option| Description
    ---|---
    Pool URL| Enter the URL of your desired pool.
    The S17e servers can be set up with three mining pools, with decreasing priority from the first pool (pool 1) to the third pool (pool 3).
    The pools with low priority will only be used if all higher priority pools are offline.
    Worker| Your worker ID on the selected pool.
    Password| The password for your selected worker.
  3. Click Save & Apply to save and restart the server.

Monitoring Your server

To check the operating status of your server:

  1. Click the status marked below. (Here takes the server status of S17e-64T as an example)BITMAIN s9 Bitcoin Antminer - Monitoring Note: The S17e server is with automatic frequency. Firmware will stop running when the Temp (PCB) reaches to 80 ℃ or Temp(chips) reaches to 95 ℃ ,there will be an error message “Fatal Error: Temperature is too high!” shown in the bottom of kernel log page.
  2. Monitor your server according to the descriptions in the following table:
    Option| Description
    ---|---
    ASIC#| Number of chips detected in the chain.
    Frequency| ASIC frequency setting.
    GH/S(RT)| Hash rate of each hash board (GH/s).
    Temp(PCB)| Temperature of each hash board (°C). (Applied only to server with fixed frequency).
    Temp(Chip)| Temperature of the chips on each hash board (°C).
    ASIC status| One of the following statuses will appear:
    O – indicates OK
    X – indicates error
    ●  – indicates dead

Administering Your Server

5.1 Checking Your Firmware Version
To check your firmware version:

  1. In System, click the Overview tab.
  2.  File System Version displays the date of the firmware your server uses. In the examples below, the servers are respectively using firmware version 20190910.

BITMAIN s9 Bitcoin Antminer - Firmware Version

5.2 Upgrading Your System
Make sure that the S17e server remains powered during the upgrade process. If power fails before the upgrade is completed, you will need to return it to Bitmain for repair.
To upgrade the server’s firmware:

  1. In System, click Upgrade.BITMAIN s9 Bitcoin Antminer - firmware

  2. For Keep Settings:
    ■ Select the check box to keep your current settings (default).
    ■ Clear the check box to reset the server to default settings.

  3. Click the (Browse) button and navigate to the upgrade file. Select the upgrade file, then click Flash image. A message appears notifying you if the S17e firmware can be upgraded and if yes, will then proceed to flash the image.

  4. When the upgrade is completed, the following message appears:BITMAIN s9 Bitcoin Antminer - Keep Settings

  5. Click one of the following options:
    ■ Reboot – to restart the server with the new firmware.
    ■ Go Back – to continue mining with the current firmware. The server will load the new firmware next time when it is restarted.

5.3 Modifying Your Password
To change your login password:

  1. In System, click the Administration tab.
  2. Set your new password, then click Save & Apply.

BITMAIN s9 Bitcoin Antminer - Password

5.4 Restoring Initial Settings
To restore your initial settings

  1. Turn on the server and let it run for 5 minutes.
  2. On the controller front panel, press and hold the Reset button for 10 seconds.
    Resetting your server will reboot it and restore its default settings. The red LED will automatically flash once every 15 seconds if the reset is operated successfully.

Environmental Requirements
Please run your server in accordance with the following requirements

  1. Basic Environmental Requirements:
    1.1. Climatic Conditions: Description| Requirement
    ---|---
    Operating Temperature| 0-40℃
    Operating Humidity| 10-90%RH (non-condensing)
    Storage Temperature| -20-70℃
    Storage Humidity| 5-95%RH(non-condensing)
    Altitude| <2000m

1.2. Site Requirements of the Server Running Room:
Please keep the server running room away from industrial pollution sources:
For heavy pollution sources such as smelters and coal mines, the distance should be more than 5km.
For moderate pollution sources such as chemical industries, rubber and electroplating industries, the distance should be more than 3.7km.
For light pollution sources such as food factories and leather processing factories, the distance should be more than 2km.
If unavoidable, the site should be chosen in the perennial upwind direction of the pollution source.
Please do not set your location within 3.7km from the seaside or the salt lake. If unavoidable, it should be built as airtight as possible, equipped with air conditioning for cooling.
1.3. Electromagnetic Environmental Conditions:
Please keep your site away from transformers, high-voltage cables, transmission lines and high-current equipment, for example, there should be no high-power AC transformers (>10KA) within 20 meters, and no high-voltage power lines within 50 meters.
Please keep your site away from high-power radio transmitters, for example, there should be no high-power radio transmitters (>1500W) within 100 meters.

  1. Other Environmental Requirements:
    The server running room shall be free of explosive, conductive, magnetically conductive and corrosive dust. The requirements of mechanical active substances are shown below:
    2.1 Requirements of Mechanical Active Substances**** Mechanical Active Substance| Requirement
    ---|---
    Sand| <= 30mg/m3
    Dust (suspended)| <= 0.2mg/m3
    Dust (deposited)| <=1.5mg/m2h

2.2 Requirements of Corrosive Gas****

Corrosive Gas Unit Concentration
H2S ppb < 3
SO2 ppb < 10
Cl2 ppb < 1
NO2 ppb < 50
HF ppb < 1
NH3 ppb < 500
O3 ppb < 2

Note: ppb (part per billion) refers to the unit of concentration,1ppb stands for the volume ratio of part per billion.

Regulations:
FCC Notice (FOR FCC CERTIFIED MODELS):
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference  that may cause undesired operation.
Note:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will  be required to correct the interference at his own expense.
EU WEEE: Disposal of Waste Equipment by Users in Private Household in the European Union
This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handling it over to a designated  collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a  manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop  where your purchased the product.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals