www.bitmain.com
1. Specification
Product Glance|
Value
---|---
Model|
S19 Hyd.
Version|
208-A
Crypto algorithm/coins|
SHA256|BTC/BCH
Typical Hashrate, TH/s (1-1)|
151.5
Power on wall @35℃(1-2), Watt (1-1)|
5227
Power efficiency on wall@35℃(1-2) , J/TH (1-1)|
34.5
Detailed Characteristics|
Value
---|---
Power supply
Power supply AC input voltage, Volt (2-1)|
380~415V AC
Power supply AC Input Frequency Range, Hz|
50~60
Power supply AC Input current, Amp (2-2)|
12
Hardware configuration
Network connection mode|
RJ45 Ethernet 10/100M
Server size (LengthWidthHeight, w/o package), mm|
412197209
Server size (LengthWidthHeight, with package), mm|
570316430
Net weight, kg|
15.8
Gross weight, kg|
17.7
Environment requirements
Inlet water temperature, °C|
35
Water flow, L/min|
8.0~10.0
Water pressure bar|
≤3.5
Working fluid(2-3)|
Deionized water/Pure water
Liquid PH |
8.5~9.5
Diameter of water pipe connector, mm|
DN10
Storage temperature, °C|
-20~70
Operation humidity(non-condensing), RH|
10~90%
Notes:
(1-1) The Hashrate value, Power on wall, and Power efficiency on wall are all
typical values. The actual Hashrate value fluctuates by ±3%, and the actual
Power on wall and Power efficiency on wall fluctuate by ±5%.
(1-2) Inlet water temperature.
(2-1) Caution: Wrong input voltage may cause server damaged.
(2-2) Three-phase AC input, 10 A per wire.
(2-3) If the water conductivity is ≥100 μs/cm, the fluid must be replaced. The
water conductivity is less than 20 μs/cm when the system is running at the
first time.