BITMAIN S9 AntMiner D3 Server Installation Guide
- May 15, 2024
- BITMAIN
Table of Contents
D3 Server
Installation Guide
Document Version 0.1
Aug 2017
S9 AntMiner D3 Server
© Copyright Bitmain Technologies Holding Company 2007 – 2022. All rights
reserved.
Bitmain Cayman (hereinafter referred to as ‘Bitmain’) reserves the right
tomake corrections, modifications, enhancements, improvements, and other
changes to its products and services at any time and to discontinue any
product or service without notice.
Customers should obtain the latest relevant information before placing orders
and should verify that such information is current and complete. All products
are sold subject to Bitmain’s terms and conditions of sale supplied at the
time of order acknowledgment.
Bitmain warrants performance of its products to the specifications applicable
at the time of sale in accordance with Bitmain’s standard warranty. Testing
and other quality control techniques are used to the extent Bitmain deems
necessary to support this warranty. Except where mandated by government
requirements, testing of all parameters of each product is not necessarily
performed.
Bitmain assumes no liability for third-party applications assistance.
Customers are responsible for their products and applications using Bitmain
components. To minimize the risks associated with customer products and
applications, customers should provide adequate design and operating
safeguards.
Bitmain does not warrant or represent that any license, either express or
implied, is granted under any Bitmain patent right, copyright or other
Bitmain intellectual property right relating to any combination, machine, or
process in which Bitmain products or services are used. Information published
by Bitmain regarding third-party products or services does not constitute a
license fromBitmain to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license froma third
party under the patents or other intellectual property of the third party, or
a license from Bitmain under the patents or other intellectual property of
Bitmain.
Resale of Bitmain products or services with statements different from or
beyond the parameters stated by Bitmain for that product or service voids all
express and any implied warranties for the associated Bitmain product or
service and is an unfair and deceptive business practice. Bitmain is not
responsible or liable for any such statements.
All company and brand products and service names are trademarks or registered
trademarks of their respective holders.
All text and figures included in this publication are the exclusive property
of Bitmain, andmay not be copied, reproduced, or used in any way without the
express written permission of Bitmain. Information in this document is subject
to change without notice and does not represent a commitment on the part of
Bitmain.
Although the information in this document has been carefully reviewed, Bitmain
does not warrant it to be free of errors or omissions. Bitmain reserves the
right to make corrections, updates, revisions or changes to the information in
this document.
Bitmain
Tel:+86-400-890-8855
www.bitmain.com
Overview
The D3 server is Bitmain’s newest version in the D3 server series. It boasts a state-of-the-art BM1760 custom-made chip using 28nm technology. All D3 servers are tested and configured prior to shipping to ensure easy set up.
** Power supply unit is not included. Please provide your own ATX power
supply.
1.1 D3 Server Components**
The D3 server main components and controller front panel are shown in the
following figure:
1.2 Specification
Hash Rate | 17 GH/s±5% |
---|---|
Rated voltage | 11.60 ~ 13.00V |
Frequency | 487M |
Estimated wall outlet power consumption (with APW3, 93% efficiency, 25°C
ambient temperature)| 970W + 7%
Estimated wall outlet power efficiency (with APW3, 93% efficiency, 25°C
ambient temperature)| 57mJ/MH + 7%
Dimensions (L x W x H)| 320mm130mm190mm
Net weight without packaging| 4.2kg
Operating ambient temperature| 0 ~ 40°C
**** The server does not contain a DC/DC converter; therefore, higher input voltage will cause higher Mining efficiency.
Connecting the Power Supply
Ten PCI-e connectors are located at the top of the D3 server for connecting the PSU as follows:
- Nine PCI-e connectors for the hash boards. Each hash board has a set of three PCI-e connectors.
- One PCI-e connector located on the controller.
** Each hashboard must be powered by the same PSU on both connectors to
prevent Possible damage and instability.
To connect the power supply:**
- Connect PSU power cable connectors to each of the nine PCI-e connectors on the top of the D3 server , ensuring that each hash board is powered by the samePSU.
- Connect a PSU power cable connector to the D3 server PCI-e connector on the controller.
- Connect the network cable to the ETH port. (WIFI is unavailable for servers)
- To power up your D3 server, connect the PSUs to the power wall outlet.
**** If you are using more than one PSU, power up the PSU connected to the controller AFTER you have powered up the other PSU(s).
Setting Up Server
To set up the server:
**** The file IPReporter.zip is supported by Microsoft Windows only.
-
Go to the following site: https://shop.bitmain.com/support/download
-
Choose ‘Others’ and download the file: IPReporter.zip
-
Extract the file.
**** The default DHCP network protocol distributes IP addresses automatically. -
Right-click IPReporter.exe and run it as Administrator.
-
Select one of the following options:
■ Shelf, Step, Position – suitable for farm servers to mark the location of the servers.
■ Default – suitable for home servers. -
Click Start.
-
On the controller board, click the IP Report button. Hold it down until it beeps (about 5 seconds).The IP address will be displayed in a window on your computer screen.
-
In your web browser, enter the IP address provided.
-
Proceed to login using root for both the username and password.
-
In the Network section, you can assign a Static IP address (optional).
-
Click Save & Apply.
Configuring the Server
4.1 Setting Up the Pool
To configure the server:
- Click General Settings.
- Set the options according to the following table:
Option| Description
---|---
Pool URL| Enter the URL of your desired pool.
**** The D3 server can be set up with three mining pools, with decreasing priority from the first pool (pool 1) to the third pool (pool 3).
The pools with low priority will only be used if all higher priority pools are offline.
Worker| Your worker ID on the selected pool.
Password| The password for your selected worker. - Click Save & Apply.
4.2 Modifying the Frequency
You are able to modify the frequency value through ‘ Configuration —>Advanced
Settings’.
**** Bitmain recommend a default frequency of D3 server , and Overlocking the
server will void the warranty immediately.
Monitoring Your Server
To check the operating status of your server:
- Click the status marked below.
- Monitor your server according to the descriptions in the following table:
Option | Description |
---|---|
ASIC# | Number of chips detected in the chain. |
Frequency | ASIC frequency setting. |
GH/S(RT) | Hash rate of each hash board ( GH/s) |
Temp(PCB) | Temperature of each hash board (°C).(Applied only to server with |
fixed frequency)
Temp(Chip)| Temperature of the chips on each hash board (°C).
ASIC status| One of the following statuses will appear:
● O – indicates OK
● X – indicates error
● – – indicates dead
Note: The D3 server will stop running when the Temp(PCB) exceeds to 85°C, there will be an error message “Fatal Error: Temperature is too high!” shown in the bottom of kernel log page.
Administering Your Server
6.1 Checking Your Firmware Version
To check your firmware version:
- In System, click the Overview tab.
- File System Version displays the date of the firmware your server use. (Screenshot below of S9 server just for your reference to display themessage, themessage shows on your computer shall prevail.
6.2 Upgrading Your System
** Make sure that the D3 server remains powered during the upgrade process.
If power fails before the upgrade is completed, you will need to return it to
Bitmain for repair.
To upgrade the server’s firmware:**
-
In System, click Upgrade.
-
For Keep Settings:
■ Select the check box to keep your current settings (default).
■ Clear the check box to reset the server to default settings. -
Click the (Browse) button and navigate to the upgrade file. Select the upgrade file, then click Flash image. Amessage appears notifying you if theD3 server firmware can be upgraded and if yes, will then proceed to flash the image. (Note: Please do not extract the update file and keep the power on during updating firmware or otherwise the server needs to be returned to the factory to repair. And around twominutes will be needed to complete updating.)
-
When the upgrade is completed successfully, the following message will appear: (Screenshot below of S9 server just for your reference to show the message, the message shows on your computer shall prevail).
6.3 Modifying Your Password
To change your login password:
- In System, click the Administration tab.
- Set your new password, then click Save & Apply.
6.4 Restoring Initial Settings
To restore your initial settings, two methods below for your reference.
- Turn on the server and let it run for 5minutes.
- On the controller front panel, press and hold the Reset button for 10 seconds.
**** Resetting your server will reboot it and restore its default settings. The red LED will automatically flash once every 15 seconds if the reset is operated successfully.
Regulation:
FCC Notice (FOR FCC CERTIFIED MODELS):
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation.
Note:
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
EU WEEE: Disposal of Waste Equipment by Users in Private Household in the
European Union
**** This symbol on the product or on its packaging indicates that this
product must not be disposed of with your other household waste. Instead, it
is your responsibility to dispose of your waste equipment by handling it over
to a designated collection point for the recycling of waste electrical and
electronic equipment. The separate collection and recycling of your waste
equipment at the time of disposal will help to conserve natural resources and
ensure that it is recycled in a manner that protects human health and the
environment. For more information about where you can drop off your waste
equipment for recycling, please contact your local city office, your household
waste disposal service or the shop where your purchased the product.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>