BITMAIN DR5 Server Installation Guide
- May 15, 2024
- BITMAIN
Table of Contents
DR5 Server
Installation Guide
Document Version 0.1
Jan. 2019
DR5 Server
© Copyright Bitmain Technologies Holding Company 2007 – 2022. All rights
reserved.
Bitmain Cayman (hereinafter referred to as ‘Bitmain’) reserves the right to
make corrections, modifications, enhancements, improvements, and other changes
to its products and services at any time and to discontinue any product or
service without notice.
Customers should obtain the latest relevant information before placing orders
and should verify that such information is current and complete. All products
are sold subject to Bitmain’s terms and conditions of sale supplied at the
time of order acknowledgment.
Bitmain warrants performance of its products to the specifications applicable
at the time of sale in accordance with Bitmain’s standard warranty. Testing
and other quality control techniques are used to the extent Bitmain deems
necessary to support this warranty. Except where mandated by government
requirements, testing of all parameters of each product is not necessarily
performed.
Bitmain assumes no liability for third‐party applications assistance.
Customers are responsible for their products and applications using Bitmain
components. To minimize the risks associated with customer products and
applications, customers should provide adequate design and operating
safeguards.
Bitmain does not warrant or represent that any license, either express or
implied, is granted under any Bitmain patent right, copyright or other Bitmain
intellectual property right relating to any combination, machine, or process
in which Bitmain products or services are used. Information published by
Bitmain regarding third‐party products or services does not constitute a
license from Bitmain to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a
third party under the patents or other intellectual property of the third
party, or a license from Bitmain under the patents or other intellectual
property of Bitmain.
Resale of Bitmain products or services with statements different from or
beyond the parameters stated by Bitmain for that product or service voids all
express and any implied warranties for the associated Bitmain product or
service and is an unfair and deceptive business practice. Bitmain is not
responsible or liable for any such statements.
All company and brand products and service names are trademarks or registered
trademarks of their respective holders.
All text and figures included in this publication are the exclusive property
of Bitmain, and may not be copied, reproduced, or used in any way without the
express written permission of Bitmain. Information in this document is subject
to change without notice and does not represent a commitment on the part of
Bitmain. Although the information in this document has been carefully
reviewed, Bitmain does not warrant it to be free of errors or omissions.
Bitmain reserves the right to make corrections, updates, revisions or changes
to the information in this document.
Bitmain
Tel: +86‐400‐890‐8855
www.bitmain.com
Overview
The DR5 server is Bitmain’s newest version in the DR5 server series. Power supply APW8 is part of DR5 server. All DR5 servers are tested and configured prior to shipping to ensure easy set up.
Caution:
- The socket-outlet shall be installed near the equipment and shall be easily accessible.
- Please refer to the layout above to place your goods in usage in case of any damage.
1.1 DR5 Server Components
The main components and controller front panel of DR5 server are shown in the
following figure:
APW8 Power Supply:
Note:
- Power supply APW8 is part of DRS server. For detailed parameters, please refer to the specifications below.
- Additional power cord is needed.
1.2 Specifications
Model No.: 240 ‐A
Version: DR5
Product Glance | Value |
---|---|
Normal | Low Power |
Crypto Algorithm | Blake256R14 |
Hashrate, TH/s | 35.00 |
Reference power on wall, Watt | 1610 |
Reference power efficiency on wall @ 25°C , J/TH | 46.00 |
40.00
Detailed Characteristics| Value
---|---
Min| Typ| Max
Hashrate & Power
Hashrate. THIS| Normal| | 35.00| 35.95
Low Power| | 25.00-26.00| +3%
(1-1)
Power efficiency on wall @25°C. JITH| Normal| 46.00| | 49.22
Low Power| 40.00| | 42.80
Power efficiency on wall @40°C. JITH| Normal| 47.53| | 50.86
Low Power| 41.42| | 44.32
Power on wall, Watt (I-2)| Normal| 1610| | 1828
Low Power| 1000| | 1187
Power supply AC input voltage, Volt (1 ‐ 3)| | 200| 220| 240
Power supply AC input current. Amps(1-4)| Normal| | 7.32| 9.14
Low Power| | 4.55| 5.94
Power supply Input AC Frequency Range. Hz| | 47| 50| 63
Hardware Configuration
Quantity of hash chips| 216
Quantity of hash boards| 3
Networking connection mode| RJ45 Ethernet 10/100M
Server Size (LengthWidthHeight, w/o package), mm (2‐ 1)|
238178297
---|---
Net weight, kg (2‐ 2)| 7.75
Noise, dBA @25 °C (2 ‐ 3)| | | | 76
Environmental Requirements
Operation temperature, °C| | 0| 25| 40
Storage temperature, °C| | ‐ 4 0| 25| 85
Operation humidity, RH (no condensation)| | 5%| | 95%
Notes:
(1 ‐1) In Low Power Mode, Max Hashrate is about Typ hashrate *103%
(1‐2) Min condition: 25°C, min J/TH, typical hashrate
Max condition: 40°C, max J/TH, max hashrate
(1 ‐3) Caution: Wrong input voltage may probably cause server damaged
(1‐4) Typ condition: min reference power, typical AC input voltage
Max condition: max reference power, min AC input voltage
(2‐1) Including PSU size
(2 ‐2) Including PSU weight
(2‐3) Max condition: Fan is under max RPM(rotation per minute)
Specifications for APW8:
**** Input | Voltage Range | 200‐240V AC |
---|---|---|
Frequency Range | 50/60Hz | |
Power Factor | >0.99 | |
Leakage Current | <2mA | |
Overheat Protection | Yes | |
**** Environment | Operating Temperature | 0℃‐40℃ |
Operating Humidity | 5%RH‐95%RH(non‐‐‐condensing) | |
Cooling System | Fan | forced‐‐‐air cooling |
Setting Up the Server
To set up the server:
The file IPReporter.zip is supported by Microsoft Windows only.
-
Go to the following site:https://shop.bitmain.com/support/download
-
Choose ‘Others’ and download the following file: IPReporter.zip
-
Extract the file.
The default DHCP network protocol distributes IP addresses automatically. -
Right‐click IPReporter.exe and run it as Administrator.
-
Select one of the following options:
■ Shelf, Step, Position – suitable for farm servers to mark the location of the servers.
■ Default – suitable for home servers. -
Click Start.
-
On the controller board, click the IP Report button. Hold it down until it beeps (about 5 seconds).
The IP address will be displayed in a window on your computer screen. -
In your web browser, enter the IP address provided.
-
Proceed to login using root for both the username and password.
-
In the Network section, you can assign a DHCP IP address (optional).
-
Click Save & Apply.
Configuring the Server Setting Up the Pool
To configure the server:
-
click General Settings
Note: There are two modes of Hashrate which u may adjust: Normal and Low power mode. Power consumption vs varies with different mode. Please refer to the specifications above for more details. -
Set the options according to the following table:
Option| Description
---|---
Pool URL| Enter the URL of your desired pool.
The DR5 server can be set up with three mining pools, with decreasing priority from the first pool (pool 1) to the third pool (pool 3).
The pools with low priority will only be used if all higher priority pools are offline.
Worker| Your worker ID on the selected pool.
Password| The password for your selected worker. -
Click Save & Apply to save and restart the server.
Monitoring Your server
To check the operating status of your server:
-
Click the status marked below.
Note: The DRS server is with fixed frequency adjustment 600 MHZ. Firmware will stop running when the Temp(chips) reaches to 100°C. there will be an error message “Fatal Error: Temperature is too high!” shown in the bottom of kernel log page. -
monitor your server according to the descriptions in the following table:
Option| Description
---|---
ASIC#| Number of chips detected in the chain.
Frequency| ASIC frequency setting.
GH/S(RT)| Hash rate of each hash board ( GH/s)
Temp(PCB)| Temperature of each hash board (°C).(Applied only to server with fixed frequency)
Temp(Chip)| Temperature of the chips on each hash board (°C).
ASIC status| One of the following statuses will appear:
● O ‐ indicates OK
● X ‐ indicates error
● ‐ ‐ indicates dead
Administering Your Server
5.1 Checking Your Firmware Version
To check your firmware version:
- In System, click the Overview tab.
- File System Version displays the date of the firmware your server use. In the example below, the server is using firmware version 20181211.
5.2 Upgrading Your System
Make sure that the DR5 server remains powered during the upgrade process. If power fails before the upgrade is completed, you will need to return it to Bitmain for repair.
To upgrade the server’s firmware:
-
In System, click Upgrade.
-
For Keep Settings:
■ Select the check box to keep your current settings (default).
■ Clear the check box to reset the server to default settings. -
Click the (Browse) button and navigate to the upgrade file. Select the upgrade file, then click Flash image.A message appears notifying you if the DR5 firmware can be upgraded and if yes, will then proceed to flash the image.
-
When the upgrade is completed, the following message appears:
-
Click one of the following options:
■ Reboot ‐ to restart the server with the new firmware.
■ Go Back ‐ to continue mining with the current firmware. The server will load the new firmware next time it is restarted.
5.3 Modifying Your Password
To change your login password:
- In System, click the Administration tab.
- Set your new password, then click Save & Apply.
5.4 Restoring Initial Settings
To restore your initial settings
- Turn on the server and let it run for 5 minutes.
- On the controller front panel, press and hold the Reset button for 10 seconds.
Resetting your server will reboot it and restore its default settings. The red LED will automatically flash once every 15 seconds if the reset is operated successfully.
Regulations:
FCC Notice (FOR FCC CERTIFIED MODELS):
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference
received,including interference that may cause undesired operation.
Note:
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
EU WEEE: Disposal of Waste Equipment by Users in Private Household in the
European Union
This symbol on the product or on its packaging indicates that this product
must not be disposed of with your other household waste. Instead, it is your
responsibility to dispose of your waste equipment by handling it over to a
designated collection point for the recycling of waste electrical and
electronic equipment. The separate collection and recycling of your waste
equipment at the time of disposal will help to conserve natural resources and
ensure that it is recycled in a manner that protects human health and the
environment. For more information about where you can drop off your waste
equipment for recycling, please contact your local city office, your household
waste disposal service or the shop where your purchased the product.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>