Trudian Wiegand Access Control Reader User Manual
- July 13, 2024
- Trudian
Table of Contents
Trudian Wiegand Access Control Reader
Product Information
Specifications:
- Working voltage: DC12V
- Swipe distance: 0~6CM
- Working current:
- Card type: reading IC card
- Communication mode: Wegen 26 / Wegen 34
- Working temperature: -40°C to -70°C
- Relative humidity: 10% to 93%
- Open mode: Swipe card
- Size: 118 72 16MM
- Installation method: Hanging installation
Product Overview
Parameter:
Working voltage | DC12V |
---|---|
Swipe distance | 0~6CM。 |
Working current | 60mA±20mA |
Card reading type | IC card |
Communication mode | Wegen 26 / Wegen 34 |
Working temperature | -40℃~-70℃ |
Relative humidity | 10%~93% |
Open mode | Swipe card |
Size | 118 72 16MM |
Installation method | Hanging installation |
Product Usage Instructions
Installation:
Refer to the Wiegand Reader Installation Diagram for proper installation.
Wiegand Reader Installation diagram
- Use the matching screwdriver to remove the read head device wall plate;
- Select a mounting location, mark the screw holes, drill 3-4 holes and use a hammer to tap in the expansion plugs;
- Fix the wall plate of the read head device to the wall with screws and connect the wires;
- Install the read head device, first snap the read head device into the wall plate from top to bottom, then align the bottom of the read head device with the screw holes of the wall plate, and finally screw on the screws to fix it.
Wiring Instruction:
Wire color | Function |
---|---|
Red Line | DC12V |
Black Line | GND |
Green Line | D0 |
White Line | D1 |
Yellow Line | WG34 |
Blue Line | LED/BZ |
Notes
- Before powering up, you must confirm the voltage of the power supply and the positive and negative terminals of the power supply.
- When using external power supply, it is recommended tos hare the power ground with the controller power supply.
- Read the head to the control box wire, it is recommended to use 8-core shielded multi-strand twisted pair network cable.Three of the cores standby, if you do not need to read the head sound and LED light feedback legal card, may not be connected to LED/BZ line, Wegen data line D0 and D1 is recommended for each other better twisted pair, line cross-sectional area recommended 0.22 square millimeters or more, it is recommended that the wiring length does not exceed 100 meters,shielded wire connected to the control box motherboard GND, thickened or double stranded together a power supply to the reading head, help to enhance the performance of the reading head.(You can also use other multi-core shielded Category 5 wire)
Frequently Asked Questions
Q: What is the working voltage of the Wiegand Access Control Reader?
A: The working voltage is DC12V.
Q: What card types can be read by the reader?
A: The reader can read IC cards.
Q: What is the communication mode supported by the reader?
A: The reader supports Wegen 26 and Wegen 34 communication modes.
Read User Manual Online (PDF format)