Thank you for purchasing our smoke alarm device. Please read this manual carefully to ensure proper use and store it in a safe place for future reference.
Product Specifications
-
Power: DC 3V
-
Battery Package:CR14505 1600mAh
-
Operation Current: <1 0UA (standby); <70mA (alarm)
-
Alarm Volume: >85 dB(A) at 3 meters
-
Alarm Sensitivity: 0.09 – 0.17 dB/m
Low Battery: 2.6 $ 0.1 V -
Silence Time: approx. 10 minutes
-
Comply to Standard EN1 4604:2005/AC:2008
Packing List
- 1 X Photoelectric smoke alarm
- 1 × Mounting bracket
- 1 X Screw kit
- 1 x Adhesive tape
- 1 X User manual
Product Profile
Installation Instructions
Where to install
- At first you should install an alarm in the bedroom and walkway. If there are several bedrooms in the house, please install an alarm in every bedroom.
- Install an alarm above the stairway and on every floor of the house.
- Smoke, heat and burning things will spread horizontally after rising to the ceiling, so install the alarm in middle of the ceiling.
- If the alarm can’t be installed in the middle of the ceiling, install it keeping 300mm away from the corner. (see the figure 1).
- If the alarm is installed in the wall, it should keep 100mm away from the ceiling.
- If the length of the room or the hall is beyond 30 feet, you need to install several alarms there.
- When the wall or ceiling is slanting, the alarm needs to be installed minimum 500mm away from the highest wall or ceiling point in the room (see the figure 2).
Locations to Avoid
- High-humidity areas such as kitchens, and bathrooms;
- Next to air outlets, fans and central heating;
- Dusty, dirty areas or areas with insects;
- High-temperature and easily polluted places;
- Places with difficult access, making it difficult to operate the test function;
- Within 1.5m from lamps;
- Next to doors or windows;
- In the top of rooms with sloping roofs, the corner of the room or other dead-air spaces.
Mounting Alarms
- Twist off the mounting bracket from the alarm.
- Put the bracket on the installation position and mark the screw holes on the ceiling or the wall.
- Drill two mounting holes in the marked place by an electric drill (The diameter of the drill hole is 5mm) and insert two plastic anchor plugs by hammer.
- Screw the mounting bracket to the ceiling or the wall (Refer to figure 3).
- Attach the alarm to the mounting bracket and turn clockwise to lock the alarm
WARNING: The installation instructions must be followed strictly in case of any injury.
How to Power up & off the device
The device is turned off by default before leaving the factory, Before the
device can be used normally, the product must be activated.
Power Up–Press the test button over 5 seconds until the red LED indicator
lighted up, then release the button, the alarm will power up and can work
normally.
Power Off–Press the test button over 20 seconds until the red LED indicator
blinked twice, then release the button, the alarm will power off and be
suspended.
Test your Alarm
Test the unit to ensure proper operation by pressing the cover, the alarm will sound if the unit are working well. If no sounds, you can refer to “Trouble shooting” section for solution.
CAUTION:
-
Before mounting the alarm, please active the alarm first, PRESSING THE TEST BUTTON OVER 10 SECONDS till the LED light up.
-
DO NOT test your alarm using an open flame. This may damage the smoke alarm, or ignite combustible materials and start a structural fire.
-
DO NOT stand close to the alarm when the alarm is sounding.
Exposure at close range may be harmful to your earing, so step away when testing. -
Weekly Test: test this smoke alarm once a week.
LED Indicators
- Normal status: Green LED Flashes once every 60 seconds.
- Test status: Red LED flashes once every second.
- Hush/Silence mode: Red LED flashes once every 8 seconds.
- Low Battery status: Red LED flashes once every 60 seconds and l beep every 60 seconds.
- Fault status: the alarm will deliver beeps every 40 seconds.
Silence Mode
for During approx the unit l 0 is minutes. alarming, The you red can LED push will the flash test once button, every it will 8 be seconds, pausedit indicates the smoke alarm device is running into the silence mode. The silence feature is to be used only when a known alarm condition, such as smoke from cooking activates the alarm. The smoke alarm device will automatically reset after approximately l 0 minutes, if after this period, particles of combustion are still present, the alarm will sound again.
CAUTION:
Before using the alarm silence (silence), identify the source of the smoke and
be certain a safe condition exists.
Maintenance and Cleaning
There are a few simple steps you need do to keep it working properly.
- Test the alarm once a week.
- Do not paint the alarm. Paint will seal the vents and interfere with the sensor’s ability to detect smoke.
- Never attempt to disassemble the alarm to clean inside. This will damage the alarm.
Clean the alarm at least once a month to remove dust, dirt, or debris.
Use a vacuum cleaner with the soft brush, vacuum all sides and covers of smoke
alarm device.
WARNING:
- DO NOT PAINT YOUR SMOKE ALARM.
- The battery is sealed in cover and not replaceable, DO NOT TRY TO REPLACE THE BATTERY.
Trouble Shooting