Installation Steps:

  1. Turn off the power supply for the condensing unit before installing the IoT device.
  2. Choose a side of the condensing unit further away from the wall for better wireless network connectivity.
  3. Securely fasten the IoT device using screws and belts to tie up the cable.
  4. Unscrew the cable locker cap and connect the waterproof joint to the reserved hole.
  5. Plug the male blue terminal into CN11 (IoT) connector on the main control board of the condensing unit.
  6. Power on the condensing unit and check if the IoT device is working properly.

LED Indicators:

No. Color Indications Description
1 Blue IoT Device status Blinking indicates normal working state

Troubleshooting Steps:

  • Check No.1 LED display after power ON for 40 seconds.
  • Check No.3 LED display after two (2) minutes.
  • Check No.2 LED display after ten (10) minutes.

Warranty Registration via ESS Pro App:

Ecoer Inc. provides an easy way for dealers to help customers complete registration via ESS Pro App for monitoring units’ live data and remote field settings.

Steps for Warranty Registration:

  1. Create an Ecoer account.
  2. Add Unit (Register a new AC/HP).

For more detailed instructions, refer to ESS Pro App UM guide available on www.ecoer.com or in the app.

FCC Compliance Statement:

This device complies with part 15 of the FCC Rules. Operation is subject to conditions to avoid harmful interference and accept any received interference.

FAQ:

  • Q: How do I know if my IoT device is working properly?
    A: The normal working state of the IoT device is indicated by the blue LED blinking, with other LEDs off.

  • Q: What should I do if the IoT device fails to boot?
    A: If the IoT device fails to boot, replace it with a new one. Ensure the IoT cable is securely connected to the PCB of the condensing unit.

Installation and Troubleshooting

Ecoer Smart Inverter Unitary systems come equipped with remote monitoring and self-diagnostics technology designed to save dealers’ time when installing and servicing.
Be sure to turn off the power supply for the condensing unit before install the IoT device. Refer to the following steps to install this device.

  1. To keep the best wireless network connectivity, choose one side of the condensing unit that is further away from the wall to hang the IoT device. Use screw to tighten the device and belts to tie up the cable.
  2. Unscrew the cable locker cap and securely fasten the waterproof joint to the reserved hole (plug has to be removed).
  3. Plug the male blue terminal into CN11 (IoT) connector on main control board of the condensing unit.

Power ON the condensing unit and check if the IoT device is working properly. The normal working state of IoT device should be the blue LED (No.1) is blinking with other LEDs light OFF.

Warranty Registration via ESS Pro App

  • With the IoT device, Ecoer Inc. provides an easy way for dealers to help their customers complete registration via ESS Pro App in just minutes. Then dealers can monitor units’ live data and perform remote field settings for the condensing unit. Working alongside the Ecoer Customer Service Team, the dealer can guarantee the installation and servicing quality.
  • Alternatively, homeowner/dealer / builder can register at www.ecoer.com. But it will not allow the dealer to monitor the system.

Search ECOER on App Store or Google Play now

Download or update Ecoer Smart Service Pro App free on

Steps of warranty registration

  1. Create an ecoer account
  2. Add Unit (Register a new AC/HP)
  3. Sign an agreement with the homeowner
  4. Scan/Input serial numbers to submit

Log in www.ecoer.com or ESS Pro App >File

Installation>ESS Pro App UM to get the newest guide
©2023 ECOER INC.
43671 Trade Center Place, Suite 100 Dulles, VA 20166
Tel: 703-348-2538
www.ecoer.com

FCC Compliance Statement

Compliance Notice:

This equipment has been tested and found to comply with the limits for a Class B digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used by the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. this device must accept any interference received, including interference that may cause undesired operation.

RF Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
Warning: Any changes or modifications not expressly approved by Ecoer Inc. could void the user’s authority to operate the equipment.
FCC ID: 2BAPJ-ELO02

Ecolink Adapter Quick Start

Log in www.ecoer.com or Ecoer Smart Service (ESS) Pro App >Systems >Add Unit to get the newest guide.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals