Product Information

Specifications

Classification Type II, Class 5
Average Flexural Strength >1000 MPa
Density 6.05 g/cm3

Product Description

  • The product is a dental restoration material that is used with CAD/CAM or manual milling machines. It is designed for use in dental laboratories or by dental professionals for dental restorations.

Indications for Use

  • The device is used for dental restorations using different CAD/CAM or manual milling machines. All blocks are processed through dental laboratories or by dental professionals.

Contraindications

  • No specific contraindications are mentioned in the user manual.

Description of Label Symbols

  • The titles and symbol descriptions can be found in the symbols glossary on page 2 of the user manual.

Design of Restoration

  • It is important to observe the wall thickness recommendations as shown in Table 2 to avoid fracture of the final restoration.
  • For specific instructions on the design of restorations, please refer to the manual designated for your CAD system.

Recommended Wall Thickness Chart for Sintered
Understructures and Full Contours| Wall Thickness (substructure)
---|---
Single- and MultipleUnit (standard) Anterior| Circular – 0.5 mm Incisal/Occlusal – 0.7 mm
Posterior| Circular – 0.5 mm Incisal/Occlusal – 0.7 mm

Milling

  • Before using this product, ensure that your mill is suitable for use with the exceptional MPa strength of this product. Follow the mill manufacturer’s milling material recommendations.
  • Bridge restorations must be designed to fit within the bounding box dimensions of X: 14.4 mm, Y: 32.9 mm, and Z: 13.6 mm (height x length x width) of the block.
  • Make sure that the coolant trough filters have been cleaned according to the milling user guides before and after milling BruxZir NOW blocks. Failure to do so may result in low coolant pressure and interruptions in subsequent milling procedures.
  • Before milling operations, fill the mill coolant trough with the recommended coolant solution concentration mentioned in the milling user guide. Failure to do so may cause incomplete BruxZir NOW block milling.
  • After designing the restoration, follow your mill instructions to complete the milling process. Use a new bur for each restoration.
  • Once milled, carefully remove the restoration from the block, clean the leftover sprue, and remove all residual debris and coolant from the restoration.

Finishing

  • No sintering is required for BruxZir NOW restorations. Polishing, staining, and/or glazing are optional and can be done as desired.
  • BruxZir NOW blocks are individually designed to match the body of the indicated VITA shade. Staining may be performed to match specific prescriptions or to achieve a gingival-to-incisal blend of color.
  • Follow the manufacturer’s directions for using stain or glaze. Only low-fusing glaze may be used.

Cementation

  • No specific cements have been evaluated for BruxZir NOW restorations. Industry-approved materials and protocols for cementing zirconia restorations are acceptable.
  • Refer to the user manuals of those specific zirconia restoration cementing products for more details.

Storage

  • Before storing BruxZir NOW blocks and burs, ensure there is no damage from shipping. Check for cracks, chips, or broken mandrels.
  • Store the blocks and burs at room temperature, away from dust and potential contamination sources. When not in use, store the BruxZir NOW blocks and burs in their original packaging.

FAQ

  1. Are specific cements recommended for BruxZir NOW restorations?
    • No specific cements have been evaluated for BruxZir NOW restorations. Industry-approved materials and protocols for cementing zirconia restorations are acceptable.
    • Refer to the user manuals of those specific zirconia restoration cementing products for more details.
  2. Do I need to sinter BruxZir NOW restorations?
    • No, sintering is not required for BruxZir NOW restorations.
  3. Can I polish, stain, or glaze BruxZir NOW restorations?
    • Yes, polishing, staining, and glazing are optional and can be done as desired.
  4. What is the recommended wall thickness for BruxZir NOW restorations?
    • The recommended wall thickness can be found in Table 2 of the user manual.

Product Description

BruxZir® NOW Milling Blocks

  • BruxZir NOW is a pre-shaded, fully sintered zirconia CAD/CAM block used for fabricating single-unit or multiple-unit dental restorations with Glidewell milling systems.
  • BruxZir NOW milling blocks are available in multiple shades. BruxZir NOW is used for fabricating single-unit dental restorations, while BruxZir NOW Bridge Block is used for fabricating multiple-unit dental restorations.
  • BruxZir NOW includes three burs with three blocks, while the BruxZir NOW Bridge Block includes one bur with one block, and the method of processing the restoration is with Glidewell milling systems using fastdesign.io design software and CAM machining strategies.

Indications for Use

  • The device is used for dental restorations using different CAD/CAM or manual milling machines.
  • All blocks are processed through dental laboratories or by dental professionals.

Contraindications

BruxZir® NOW Bridge Block design is limited to a maximum of four units with a maximum of two points between pillars.

Description of Label Symbols

The titles and symbol descriptions are in the symbols glossary on page 2 of this document.

Technical Data Table

As measured according to ISO 6872:2015

Table 1

Classification – Type II, Class 5
Coefficient of Thermal Expansion (CTE) (25–500ºC)| (10–11) x 10-6 K
Average Flexural Strength| >1000 MPa
Density| 6.05 g/cm3

Design of Restoration

  • Failure to observe the wall thickness recommendations as shown in Table 2 may result in fracture of the final restoration.
  • For specific instructions on the design of the restorations, please refer to the manual designated for your CAD system.

Table 2

__

Recommended Wall Thickness Chart for Sintered Understructures and Full Contours

| Single- and Multiple- Unit (standard)
__**Anterior| Wall Thickness**

(substructure)

| __ ≥ 0.5 mm

≥ 0.7 mm

Circular Incisal/Occlusal
__**Posterior| Wall Thickness**

(substructure)

| __ ≥ 0.5 mm

≥ 0.7 mm

Circular Incisal/Occlusal

Milling

  • Caution: Due to the exceptional MPa strength of this product, this product may not be suitable for use on your mill. Follow the mill manufacturer’s milling material recommendations before using this product.
  • Caution: Bridge restorations must be designed to fit in the bounding box dimension X: 14.4 mm Y: 32.9 mm Z: 13.6 mm (height x length x width) of the block.
  • Caution: Ensure that the coolant trough filters have been cleaned according to milling user guides before and after any BruxZir NOW blocks have been milled. Failure to do so may result in low coolant pressure and a pause in subsequent milling procedures.
  • Caution: Before milling operations, ensure the mill coolant trough has been filled with the coolant solution concentration that has been recommended in the milling user guide.
  • Failure to do so may cause incomplete BruxZir NOW block milling.
  • After the restoration has been designed, follow your mill instructions to complete the milling process. A new bur is required for each restoration.
  • Once milled, carefully remove the restoration from the block, clean the leftover sprue, and remove all residual debris and coolant from the restoration.

Finishing

  • No sintering is required for BruxZir NOW restorations. Polishing, staining, and/or glazing are optional and may be done as desired. BruxZir NOW blocks are individually designed to match the body of the indicated VITA shade.
  • Because the blocks are monochromatic (one color), staining may be performed to match specific prescriptions or to achieve a gingival-to-incisal blend of color.
  • Follow the manufacturer’s directions for using stain or glaze.
  • NOTE: Only low-fusing glaze may be used.

Cementation

  • No specific cements have been evaluated for BruxZir NOW restorations. Industry-approved materials and protocols for cementing zirconia restoration are acceptable.
    Refer to the user manuals of those specific zirconia restoration cement-ing products for more details.

Storage

  • Before storing BruxZir NOW blocks and burs, ensure there is no damage from shipping. Shipping damage may include cracks and chips of the block, and/or broken mandrels.
  • The blocks and burs should be stored at room temperature and away from dust and potential contamination sources. When not in use, store the BruxZir NOW blocks and burs in their original packaging.

WARNINGS

  • Do not inhale dust. Do not get dust into the eyes or have prolonged contact directly with the skin.
  • Personal protective equipment (PPE) such as gloves, masks, and lab coats are recommended to avoid pos-sible contact with and irritation of the skin or eyes during processing.
  • Caution: Material may break from sprue if dropped on a hard surface.
  • NOTE: To request the SDS for this product, call Glidewell Direct at 888-303-3975.

Questions/Comments

For questions and/or comments or further instructions regarding the use of the product, please contact Glidewell Direct in the U.S. at 18651 Von Karman Ave., Irvine, CA 92612 or by calling 888-303-3975.

Symbols Glossary

BruxZir-7885-NOW-Milling-Block-FIG-1

  • BruxZir® is a registered trademark of Glidewell Laboratories.
  • VITA® is a registered trademark of VITA Zahnfabrik.