ecoer EODA19H-4860A Up to 5 Ton Inverter Split System Heat Pump Instruction Manual

June 1, 2024
ecoer

ecoer EODA19H-4860A Up to 5 Ton Inverter Split System Heat Pump

ecoer-EODA19H-4860A-Up-to-5-Ton-Inverter-Split-System-Heat-Pump-
product

Product Specifications

OUTDOOR UNIT EODA19H-4860A
Voltage-Phase-Hz 208/230-1-60
Minimum Circuit Ampacity 32.5
Max. Over-current Protection 50
COMPRESSOR Variable rotary
RLA 24.0
LRA 58.1
Drive Method Inverter
Noise-cancelling Jacket Factory installed
Crankcase Heater Internal heating
OUTDOOR FAN Propeller
Condenser Fan Motor Type Brushless DC Motor
Horse Power (HP) 1/3
Motor Speed RPM 1030
CFM @ 0 in. W.G 3550
FLA 2.5
  • OUTDOOR COIL TYPE / Copper tube with hydrophilic aluminum fins
    • Rows 2.7
    • Tube Size (in.) 9/32
    • Heating Metering Device EEV
    • Cooling Metering Device (Indoor side) TXV
  • Factory Supplied Refrigerant Charge (R-410A, oz) / Data on nameplate
    • Liquid Line Size( in. O.D.) 3/8
    • Suction Line Size (in. O.D.) 7/8
  • Dimensions (W X H X D) 29-1/8 × 33-3/16 × 29-1/8
  • Net Weight (LBS) 214
  • Shipping Weight (LBS) 249
  • Max. Line Length (FT) 150
  • Max. Elevation Difference (FT) 50

Sound pressure level (dB)

EODA19H-4860A 4Ton * 5Ton
Standard 68 70
Silent mode 64 66
Super silent mode 61 62

***** Refer to the installation manual for capacity selection.

Dimension

Using Instructions

Mechanical Specifications

Communication Method

  • Non-Communicating Inverter condensing units which are compatible with most 24Vac controlled thermostats and R-410A indoor units (TXV required).

General

The EODA19H-4860A is fully charged up to 25ft line set from the factory. This unit is designed to operate at outdoor ambient temperatures as high as 125℉(and as low as 20℉) in cooling mode, and as low as -4℉ in heating mode. Cooling/Heating capacities are matched with air handler that are AHRI certified. The units are certified to ETL.

Casing

  • Unit casing is constructed of heavy gauge, Galvanized steel and painted with a weather resistant powder paint on all grilles, panels.

Refrigerant Controls

  • Refrigeration system controls include condenser fan, compressor inverter drive, electronic expansion valve and reversing valve.

Rotary Compressor

  • Flexible capacity output from 25%-110%.
  • Compressor is equipped with Noise-cancelling Jacket.

Condenser Coil

  • The outdoor coil provides low airflow resistance and efficient heat transfer.
  • The coil is protected on all four sides by grille panels.

Manufacturer reserves the right to change specifications or designs without notice.