levenhuk Wezzer Air MC10 Air Quality Monitor
Parts overview and screen interface
- Power button
- Left button
- Right button
- Current CO2 value (ppm)
- Temperature
- Humidity
- MIN. CO2 value
- MAX. CO2 value
The kit includes:
CO2 monitor, USB cable, user manual, and warranty.
Caution!
Please remember that main voltage in most European countries is 220–240V. If
you want to use your device in a country with a different mains voltage
standard, remember that use of a converter is absolutely necessary.
Charging the device
Connect the power cable to the device and the DC adapter (not included) via a
USB plug and connect it to the AC power supply. Attention! The device operates
from the AC power supply, as the voltage of the computer’s USB port is
insufficient for the proper operation of the device.
Using
Press (1) for 3 seconds to turn the device on.
Acoustic alert
Press (1) twice to turn the CO2 alarm. The digits that are to be set are
flashing. Press (2) or (3) to change the value. Press (1) again to confirm.
Press (1) to disable the sound alarm.
Specifications
- Operating CO2 range 400–5000ppm
- Air humidity, units of measurement % (RH)
- Operating humidity range 20… 85%
- Temperature, units of measurement °C
- Operating temperature range –10… +50°C (+14… +122°F)
- Power supply Li-ion battery (1600 mA∙h), DC adapter 5V 1000mA (not included)
- USB cable included
The manufacturer reserves the right to make changes to the product range and specifications without prior notice.
Care and maintenance
Take the necessary precautions when using the device with children or others who have not read or who do not fully understand these instructions. Make sure that the airflow channels at the back of the device are not blocked or covered. Do not try to disassemble the device on your own for any reason. For repairs and cleaning of any kind, please contact your local specialized service center. Protect the device from sudden impact and excessive mechanical force. Store the device in a dry cool place. Only use accessories and spare parts for this device that comply with the technical specifications. Never attempt to operate a damaged device or a device with damaged electrical parts! If a part of the device or battery is swallowed, seek medical attention immediately. Children should use the device under adult supervision only.
Battery safety instructions
Always purchase the correct size and grade of battery most suitable for the intended use. Always replace the whole set of batteries at one time; taking care not to mix old and new ones or batteries of different types. Clean the battery contacts and also those of the device prior to battery installation. Make sure the batteries are installed correctly with regard to polarity (+ and –). Remove batteries from equipment that is not to be used for an extended period of time. Remove used batteries promptly. Never short-circuit batteries as this may lead to high temperatures, leakage, or explosion. Never heat batteries in order to revive them. Do not disassemble batteries. Remember to switch off devices after use. Keep batteries out of the reach of children, to avoid the risk of ingestion, suffocation, or poisoning. Utilize used batteries as prescribed by your country’s laws.
Levenhuk International Lifetime Warranty
All Levenhuk telescopes, microscopes, binoculars, and other optical products,
except for their accessories, carry a lifetime warranty against defects in
materials and workmanship. A lifetime warranty is a guarantee of the lifetime
of the product on the market. All Levenhuk accessories are warranted to be
free of defects in materials and workmanship for six months from the purchase
date. The warranty entitles you to the free repair or replacement of the
Levenhuk product in any country where a Levenhuk office is located in all the
warranty conditions are met.
For further details, please visit
www.levenhuk.com/warranty.
If warranty problems arise, or if you need assistance in using your product, contact the local Levenhuk branch.
Levenhuk Inc. (USA): 928 E 124th Ave. Ste D, Tampa, FL 33612, USA, +1-813-468-3001, contact_us@levenhuk.com.
Levenhuk Optics s.r.o. (Europe): V Chotejně 700/7, 102 00 Prague 102, Czech
Republic, +420 737-004-919, sales-info@levenhuk.cz Levenhuk®, Wezzer® are registered trademarks of Levenhuk,
Inc. © 2006–2022 Levenhuk, Inc. All rights reserved.
www.levenhuk.com
20221010.
References
- Доживотна гаранция на Levenhuk – Официален уебсайт на Levenhuk в България
- Levenhuk’s official website in USA
- Levenhuk Limited Warranty – Levenhuk’s official website in USA
- Doživotní záruka společnosti Levenhuk – Oficiální webové stránky Levenhuk pro Českou republiku
- Levenhuk Lebenslange Garantie – Die offizielle Website von Levenhuk in Deutschland
- Garantía internacional de por vida Levenhuk – Web oficial de Levenhuk en España
- Levenhuk Lifetime Warranty – Levenhuk’s official website in USA
- A Levenhuk élettartamra szóló szavatossága – A Levenhuk hivatalos magyarországi weboldala
- Gwarancja bezterminowa Levenhuk – Oficjalna witryna internetowa Levenhuk w Polsce
- Поддержка - Гарантийное обслуживание Левенгук - Levenhuk Russia
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>