FERMAX 970189c Marine Panel User Guide

June 27, 2024
FERMAX

MARINE PANEL
QUICK START GUIDE

CONNECTIONS

Further information at meet.fermax.com

http://www.fermax.com/qr/index.asp?id=182

The device you have purchased is identified under Directive 2012/19/EU on waste electrical and electronic equipment. More info:

http://www.fermax.com/qr/index.asp?id=191

POWER INPUT: 12 Vdc power supply for the cases where no LAN PoE is available.
OUTPUT: Electric lock control relay output.

  • NC: Normally closed contact.
  • NO: Normally opened contact.
  • C: Common.

NOTE: NC & C contacts are internally duplicated.

EX PROXIMITY:

  • (WD0-WD1) Wiegand input/output.
  • (+5V, -) 5 Vdc auxiliar output.

EXIT BUTTON /FIRE / DOOR SENSOR:

  • (EXIT, -) Connections for indoor button.
  • (FIRE, -) Input for fire alarm & block doors unlock contacts.
  • (DS, -) Connection for door opened sensor.

RS485: Output for Ref.1491 / Ref.1490 / Ref.1494 / Ref.9545 module.
RJ 45 NETWORK: RJ 45 LAN connection.

BASIC DIAGRAMS

Basic diagram using Switch PoE.
Use a power supply adapted to the electric lock voltage & current.

Basic diagram using no PoE switch
Supply the panel by means of a FERMAX Ref. 4813 (12 Vdc 2A) power supply.
Use a power supply adapted to the electric lock voltage & current.
Do not power the panel and the electric lock from the same power supply.

BASIC PROGRAMMING FROM A PC

  • Panel programming is done exclusively by means of a PC connected to the same LAN, through of a web browser (Chrome preferably), accessing the IP of the panel.
  • Default IP is: 10.1.0.1.
  • The PC must have an IP of the same range as the IP of the panel.

Example: In the case that the IP of the panel is 10.1.0.1, the IP ofthe PC have to be of type 10.X.X.X with a subnet mask 255.0.0.0

  • Assign, as a minimum, the parameters indicated in the following table.
  • It is necessary to carry out a previous planning of the installation, to define the parameters to assign to each device.

To login, identify yourself with the username and password.
Default value:

  • Username: admin
  • Password: 123456

| GENERAL
1. LANGUAGE: Select the desired language (default ENGLISH).
2. TYPE: Choose BLOCK PANEL or G.E. PANEL.
Depending on the selection the fields below will be different
• If BLOCK PANEL
• BLOCK: Block number
• DEVICE NO: Device number in the block. If there is only one leave it in 1.
• If G.E. PANEL
• DEVICE NO: Entrance number in the installation.
If there is only one, leave it in 1.
Confirm with SAVE
---|---
| NETWORK
Indicate the network parameters assigned to this panel:
• IP: Panel IP address
• MASK: Subnet mask
• GATEWAY: IP of gateway
• DNS: Valid DNS IP
Confirm with SAVE

ON-SCREEN INFORMATION

It is possible to get basic information on the equipment configuration through the screen.

  1. Dial 9999, followed by the key “B”.
  2. The screen will display information about panel settins:
    • Firmware version
    • GENERAL settings
    • Serial number