MEET MARINE PANEL
INSTALLER’S MANUAL
This manual corresponds to FERMAX MARINE MEET PANEL firmware version V02.10.
FERMAX ELECTRÓNICA S.A.U.
http://www.fermax.com
MEET DIGITAL VIDEO Panel manual available at https://www.fermax.com/qr/meet/
Product Introduction
1.1 Overview
1.2 Panel Display Screen
Functions Introduction
- Call apartment
- Call guard unit => Concierge
- Call volume settings
- Door opening, relay delay settings
- Exit button connector
- Voice Synthesizer
- Door opened, door forced alarm, and tamper alarm
- Lift control (Only when installed)
- PIN Access Code
- Mifare reader
- Alarm management by access control
- Face Recognition
- Electronic Directory
- Fire Alarm for lock release
2.1 Call Apartment
2.1.1 Enter Apartment Number
2.1.2 Call Apartment Via Directory (If enable directory)
Access to the menu, select the directory icon and press B, then search for the apartment that the Visitors need to call and press .
2.2 Call Guard Unit
2.2.1 Dial Number To Call
The visitor or resident can call the guard unit by entering the number 9901 or another number of the guard unit followed to confirm. This call can be made from all Panels.
The visitor or resident need can call the guard unit by entering the number.
2.3 Access Code
Press the key “A0” or the accessibility menu to access the PIN code function,
entering the access code followed by B to confirm.
If the access code is correct the door will open and release the lock.
You can enable or disable the function on the web of the panel.
The access code to be defined at web of the panel, Maximum access code 6.
2.4 Face Recognition
Press key “A” two times or access the menu to access the face recognition
function, and the camera of the panel will start to read the face information.
If the face data is authorized, the door will open and release the lock. The
face data is to be added through the management software. Maximum face data
6000.
2.5 Mifare Reader
Resident can access to their corresponding entrance by passing their
authorized Mifare card, the door will open and release the lock. The Mifare
card data is to be added through management software, Maximum of 100,000
Mifare cards.
2.6 Fire Alarm
When a fire alarm occurs, the panel will appear a “Fire Alarm” prompt and
automatically release all locks in this block to facilitate the safe
evacuation of residents.
2.7 About
Enter code 9999 followed by B to confirm, The About information will show.
You can get information about the device name, firmware version, device info, serial no, IP address, MAC address.
Configuration via Web Server
The panel has an integrated web server, which allows for configuring the
parameters. This web server is accessed via the panel’s IP address.
The browser opens with the configured IP address of the panel. A screen opens
requesting a username and password
Default IP: 10.1.0.1
Username: admin
Password: 123456
3.1 Device Information
The following information is displayed: the device name, firmware version, device info, serial no, MAC address, IP address.
3.2 General Settings
Configures the panel type: General entrance panel or block panel.
3.2.1 General Entrance Panel
DEVICE NO.: General entrance panel number, between 1 and 9000.
TYPE: For General Entrance select G.E.PANEL. The panel can communicate with
all devices of the installation.
LANGUAGE: select the desired language in the dropdown options. (default option
ENGLISH).
Refresh the webpage after changing the language.
INFORMATION: 9901 GUARD UNIT, Prompt information to be displayed on the panel,
between 9901-9998, default option 9901. It is possible to modify the number
according to the Guard Unit that each panel will call.
PANEL VOLUME: Select the desired value between 1 and 5, default option 4.
The conversation volume is common for uplink and downlink.
DOOR OPEN VOICE: Open door voice prompt can be enabled or disabled. The
default is enabled.
VIDEO RESOLUTION: In order to fit the different types of monitors. The default
value 640×480 is to be used usually.
SIP DIVERT MODE: (this feature may not be available at the time of releasing
the manual)
PARALLEL CALL: When the panel calls the resident, the monitor and the call
divert APP ring at the same time. Once one terminal answers the call the other
one stops ringing.
SEQUENTIAL CALL: When the panel calls the resident, the monitor will ring for
about 30s if no answer, the call divert APP will start to ring
DAT E FORMAT: Date format.
DAT E: Setting the date of panel.
TIME: Setting the time of panel.
TIME ZONE: Setting the time zone of panel.
DST: Enable the daylight saving time option.
Select the local time zone and save.
If the project has no management software the installer can set the date,
time, and time zone manually. If the project has management software, the date
and time of the panel will synchronize automatically with the management
software. If the panel has access to the internet, the date and time of panel
will also synchronize with the internet time server.
NOTE: Date and time can’t be saved after power loss, the time zone and
date format can be saved.
3.2.2 Block Panel
BLOCK: Block number, between 001 and 999 (default option 1).
DEVICE NO.: Panel Number, between:01-99 (default option 1).
TYPE: For block entrance, choose BLOCK PANEL. The panel can communicate with
all devices on the same block.
LANGUAGE: Select the desired language for the drop-down options. (default
option ENGLISH).
Refresh the webpage after changing the language.
INFORMATION: 9901 GUARD UNIT, Prompt information to be displayed on the panel,
between 9901-9998, default option 9901. It is possible to modify the number
according to the Guard Unit that each panel will call.
PANEL VOLUME: Select the desired value between 1 and 5, (default option 4).
The conversation volume is common for uplink and downlink.
DOOR OPEN VOICE: Open door voice prompt can be enabled or disabled. The
default is enabled.
VIDEO RESOLUTION: In order to fit the different type of monitors, The default
value 640×480 is be used usually.
SIP DIVERT MODE: (this feature may not be available at the time of releasing
the manual)
PARALLEL CALL: When the panel calls the resident, the monitor and the call
divert APP ring at the same time. Once one terminal answers the call the other
one stops ringing.
SEQUENTIAL CALL: When the panel calls the resident, the monitor will ring
about 30s if no answer, the call divert APP will start to ring
DAT E FORMAT: Date format.
DAT E: Setting the date of the panel.
TIME: Setting the time of the panel.
TIME ZONE: Setting the time zone of the panel.
DST: Enable the daylight saving time option.
Select the local time zone and save.
If the project has no management software the installer can set date, time,
and time zone manually. If the project has management software, the date and
time of the panel will synchronize automatically with the management software.
If the panel has access to the internet, the date and time of panel will also
synchronize with an internet time server.
NOTE: Date and time can’t be saved after power loss, the time zone and
date format can be saved.
3.3 Network Settings
MEET allows the installer to define the IP range according to the project
needs and make network management easier. MEET panel network mode is the
static mode. Ensure that each device has a unique IP address in the same
installation. The devices (digital panel, monitor, and guard unit) will show
IP conflict if the same IP is used on the same LAN.
IP: IP address of the panel (default option 10.1.0.1).
MASK: Subnet mask of the panel (default option 255.0.0.0).
G AT E WAY: Default gateway of the panel (default option 10.254.0.1).
DNS: DNS of the panel (default option 8.8.8.8).
SOFTWARE IP: IP address of PC where MEET management software is installed.
(default option 10.0.0.200).
SW. PIN: The pin code is to be used when the panel is registered in MEET
management software.
3.4 Access
DOOR RELAY TIME: Time for lock-release relay remains active (1-9s optional).
OPEN DOOR DE L AY: The time when the unlocked signal is sent to the start of
the relay. The delay time is useful when the lock is not closed panel (0-9s
optional).
DOOR ALARM: An alarm will be issued when the door still opens after the normal
opening time exceeds the set time. Disable, the 30s, 60s, 120s, 180s, and 250s
optional.
DOOR FORCED ALARM: An alarm will be issued when an abnormal way of opening the
door is detected.
EXT. UNLOCK: Enable or disable the external relay unlock function.
Relay 1-4 DOOR RELAY TIME: Time for lock-release relay remains active (1-9s
optional).
Relay 1-4 OPEN DOOR DELAY: The time delay between the unlock signal sent and
the relay activation. The delay time parameter is useful when the door lock is
not close to the panel (09s optional).
ADMIN CARD: Master card registered to enroll additional prox cards. When there
is no management software enter 0000 if you do not know the ID of the admin
card. The first prox card detected by the reader will act as an admin/master
card the card of the resident can be added afterward. If this method is used,
register the resident proximity id numbers on the cards.
DISARM BY CARD: When the card opens the door, the alarm status of the monitor
corresponding unit can change to HOME mode.
GUEST CODE: No function now.
ACCESS PIN: Enable or disabled the activation of the relay for PIN code
access.
UP to 8 different PIN codes per panel.
PIN length between 4 to 6 digits.
REMARK: Reference F01491 (4 relay module) must be connected to the RS485 port
of panel no.1. The module address must be set to number 2.
3.5 Face Recognition
FACE RECOGNITION: Enable or disable the face recognition function.
SIMILARITY: High, medium, and low options. The default is low.
The face data must be added through MEET management software.
3.6 IP Camera
The monitor can switch to IP CCTV camera video during a conversation. This
function allows to the configuration of IP CCTV cameras using RTSP protocol to
be displayed as an auxiliary camera to provide different view angles from the
door or related areas.
NUMBER OF CAMS: IP camera Number. Up to 4 different cameras.
CAMERA 1: IP camera name.
URL: rtsp://user:password@ip address of ip camera.
user:password: for cameras that require a username and password for the
connection. These fields are optional and depend on the RTSP stream of each IP
camera.
3.7 SIP Settings
ENABLE SIP: Enable or disable sip function.
SIP SERVER: SIP server IP address.
DOMAIN: Sip server domain.
OUTBOUND: Some servers are used when NAT is active on the router.
STUN IP: Audio and video NAT traversing public network server IP.
STUN PORT: The port of audio and video NAT traversing public network server.
H.264: Video coding parameters.
SIP USER: The username of sip account.
SIP PASS: The password of the sip account.
CONVERSATION: Conversation duration, 120s, 300s, 600s, the 1200s, and 1800s
optional.
RING TIME: Ring time, 35s, 45s, 60s, 90s, and 120s optional.
REMARK: When the panel is used as a sip device, call SIP devices or receive
calls from other SIP devices. The SIP function has to be enabled.
3.8 SIP Trunk
When there is a VoIP gateway installed on the system or a sip server has a
PSTN line.
The panel calls can be diverted to the user’s mobile phone or landline
telephone through a voice gateway.
ENABLE SIP TRUNK: Enable or disable the SIP trunk function.
URL: sip: sip account @ wan IP: 5062
3.9 Advanced
The DIRECTORY can be enabled or disabled , Press key “A8” or access the menu
to access
Directory if the directory is enabled.
3.10 Pincode Settings
This allows changing the pin code of the web server login.
3.11 Reset
RESTORE FACTORY SETTINGS: The basic settings are restored to the factory, and
the IP address will be changed to the IP: 10.1.0.1 at the factory.
REBOOT DEVICE: The panel will be restarted.
3.12 Logout
Log out the web server.
Installation
4.1 Installation height
4.2 Connectors
- 10/100Mbps RJ45 Port.
- +, —: 12Vdc Power Input.
- C, NO, NC: Relay contacts for release lock, the double terminals are the same connection.
- +5V, —, WD0, WD1: Wigand-26 protocol output or input.
- BS, —: Exit button.
- NA, —: Fire alarm. Need connected Block Device NO 1.
- —, SP: Door-open sensor.
- 485+, 485-: To lift control gateway, F01491 (4 relay module).
4.3 Technical Parameters
Power supply: 12Vdc
Standby current: 200mA
Working current: 500mA
Technical specifications of the display:
-Size: 4.3 inch
-Format: 4:3
-Resolution: 480*272
Camera pixel: 1.2 megapixels 90º
visual angle: Vertical 72º, Horizontal 54º
Minimum illumination: 0.5Lux
Maximum conversation time: 120s
Door relay time: 1-9s
Door delay time: 0-9s
IC cards: 100,000
Face data: 6000
Operating temperature: -10~40 ℃
Relative humidity: 20%~80%, without condensation
FCC Warning
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation.
NOTE 1: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
NOTE 2: Any changes or modifications to this unit not expressly approved
by the party responsible for compliance could void the user’s authority to
operate the equipment.
NOTE 3: This equipment complies with the FCC radiation exposure limits
set forth for an uncontrolled environment. This transmitter must not be co-
located or operating in conjunction with any other antenna or transmitter.
Copyright Notice
Fermax and Fermax MARINE MEET panel are trademarks of Fermax Electronica
S.A.U.
registered in the European Union and other countries.
© FERMAX ELECTRÓNICA S.A.U., 2020.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>